Literature DB >> 26550082

Pace mapping in the atrium using bipolar electrograms from widely spaced electrodes.

Raja J Selvaraj1, Sreekanth Yerram1, Pradeep Kumar1, Santhosh Satheesh1, Ajith Ananthakrishna Pillai1, Mahesh Kumar Saktheeswaran1, Jayaraman Balachander1.   

Abstract

BACKGROUND: Pace mapping is a useful tool but is of limited utility for the atrium because of poor spatial resolution. We investigated the use of bipolar electrograms recorded from widely spaced electrodes in order to improve the resolution of pace mapping.
METHODS: This prospective study included patients undergoing a clinical electrophysiology study. Unipolar pacing from either the superior or inferior lateral right atrium was performed to simulate atrial tachycardia. Twelve-lead electrocardiograms were recorded during pacing as a template. In addition, three intracardiac bipolar electrograms from a set of widely spaced electrodes were also recorded. Subsequently, unipolar pacing was performed from electrodes at known distances from the initial pacing site, and the morphology of P waves in the electrocardiogram and bipolar electrograms were compared with that of the template. Morphological comparison was performed by a cardiologist and by automated computerized matching. Spatial resolution was calculated as the minimum distance at which there was no match.
RESULTS: Fifteen patients participated in the study. Distance at which differences in morphology were noted was smaller in the bipolar electrograms compared to that indicated by P waves in the electrocardiogram, when matched by the cardiologist (6.1±3.8 mm vs. 9.9±5.2 mm, p=0.012) or by automated analysis (4±0 mm vs. 9.9±4 mm, p<0.001).
CONCLUSIONS: Use of three bipolar electrograms recorded from a set of widely spaced electrodes in the right atrium improves the resolution of pace mapping compared to that using P waves from surface electrocardiograms alone.

Entities:  

Keywords:  Arrhythmia; Atrial arrhythmia; Computerized analysis; Mapping; Pace mapping

Year:  2015        PMID: 26550082      PMCID: PMC4600891          DOI: 10.1016/j.joa.2015.02.002

Source DB:  PubMed          Journal:  J Arrhythm        ISSN: 1880-4276


  13 in total

1.  Basic assessment of paced activation sequence mapping: implications for practical use.

Authors:  Nicasio Perez-Castellano; Jesus Almendral; Julian Villacastin; Angel Arenal; Sergio Gonzalez; Javier Moreno; Ricardo Morales; Carlos Macaya
Journal:  Pacing Clin Electrophysiol       Date:  2004-05       Impact factor: 1.976

2.  A comparison of QRS complexes resulting from unipolar and bipolar pacing: implications for pace-mapping.

Authors:  A H Kadish; S Schmaltz; F Morady
Journal:  Pacing Clin Electrophysiol       Date:  1991-05       Impact factor: 1.976

3.  Differences in QRS configuration during unipolar pacing from adjacent sites: implications for the spatial resolution of pace-mapping.

Authors:  A H Kadish; K Childs; S Schmaltz; F Morady
Journal:  J Am Coll Cardiol       Date:  1991-01       Impact factor: 24.094

4.  Spatial resolution of atrial pace mapping as determined by unipolar atrial pacing at adjacent sites.

Authors:  K C Man; K K Chan; P Kovack; R Goyal; F Bogun; M Harvey; E Daoud; A Strickberger; F Morady
Journal:  Circulation       Date:  1996-09-15       Impact factor: 29.690

5.  Electrogram polarity and cavotricuspid isthmus block during ablation of typical atrial flutter.

Authors:  H Tada; H Oral; C Sticherling; S P Chough; R L Baker; K Wasmer; M H Kim; F Pelosi; G F Michaud; B P Knight; S A Strickberger; F Morady
Journal:  J Cardiovasc Electrophysiol       Date:  2001-04

6.  Effectiveness of radiofrequency catheter ablation for treatment of atrial tachycardia.

Authors:  J Goldberger; J Kall; F Ehlert; B Deal; B Olshansky; D W Benson; J Baerman; D Kopp; A Kadish; D Wilber
Journal:  Am J Cardiol       Date:  1993-10-01       Impact factor: 2.778

7.  Radiofrequency catheter ablation of ectopic atrial tachycardia using paced activation sequence mapping.

Authors:  C M Tracy; J F Swartz; R D Fletcher; H G Hoops; A J Solomon; P E Karasik; D Mukherjee
Journal:  J Am Coll Cardiol       Date:  1993-03-15       Impact factor: 24.094

8.  Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques.

Authors:  G K Feld; R P Fleck; P S Chen; K Boyce; T D Bahnson; J B Stein; C M Calisi; M Ibarra
Journal:  Circulation       Date:  1992-10       Impact factor: 29.690

9.  Contribution of the anode to ventricular excitation during bipolar programmed electrical stimulation.

Authors:  W G Stevenson; I Wiener; J N Weiss
Journal:  Am J Cardiol       Date:  1986-03-01       Impact factor: 2.778

10.  Virtual cathode effects during stimulation of cardiac muscle. Two-dimensional in vivo experiments.

Authors:  J P Wikswo; T A Wisialowski; W A Altemeier; J R Balser; H A Kopelman; D M Roden
Journal:  Circ Res       Date:  1991-02       Impact factor: 17.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.