Literature DB >> 16549613

CT dose reduction and dose management tools: overview of available options.

Cynthia H McCollough1, Michael R Bruesewitz, James M Kofler.   

Abstract

In the past decade, the tremendous advances in computed tomography (CT) technology and applications have increased the clinical utilization of CT, creating concerns about individual and population doses of ionizing radiation. Scanner manufacturers have subsequently implemented several options to appropriately manage or reduce the radiation dose from CT. Modulation of the x-ray tube current during scanning is one effective method of managing the dose. However, the distinctions between the various tube current modulation products are not clear from the product names or descriptions. Depending on the scanner model, the tube current may be modulated according to patient attenuation or a sinusoidal-type function. The modulation may be fully preprogrammed, implemented in near-real time by using a feedback mechanism, or achieved with both preprogramming and a feedback loop. The dose modulation may occur angularly around the patient, along the long axis of the patient, or both. Finally, the system may allow use of one of several algorithms to automatically adjust the current to achieve the desired image quality. Modulation both angularly around the patient and along the z-axis is optimal, but the tube current must be appropriately adapted to patient size for diagnostic image quality to be achieved. (c) RSNA, 2006.

Entities:  

Mesh:

Year:  2006        PMID: 16549613     DOI: 10.1148/rg.262055138

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  193 in total

1.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

2.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

4.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

5.  Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model.

Authors:  B M Gramer; D Muenzel; V Leber; A-K von Thaden; H Feussner; A Schneider; M Vembar; N Soni; E J Rummeny; A M Huber
Journal:  Eur Radiol       Date:  2012-07-03       Impact factor: 5.315

Review 6.  [Strategies for reducing the CT radiation dose].

Authors:  S T Schindera; C Nauer; R Treier; P Trueb; G von Allmen; P Vock; Z Szucs-Farkas
Journal:  Radiologe       Date:  2010-12       Impact factor: 0.635

7.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Optimization of computed tomography (CT) arthrography of hip for the visualization of cartilage: an in vitro study.

Authors:  Paolo Simoni; Pierre-Philippe Leyder; Adelin Albert; Françoise Malchair; Carole Maréchal; Laura Scarciolla; Bruno Beomonte Zobel; Victoria Alvarez Miezentseva; Philippe Gillet
Journal:  Skeletal Radiol       Date:  2013-11-27       Impact factor: 2.199

9.  Quality evaluation of image-based iterative reconstruction for CT: Comparison with hybrid iterative reconstruction.

Authors:  Hiroki Kawashima; Katsuhiro Ichikawa; Kosuke Matsubara; Hiroji Nagata; Tadanori Takata; Satoshi Kobayashi
Journal:  J Appl Clin Med Phys       Date:  2019-05-02       Impact factor: 2.102

10.  Intraoperative computed tomography guidance to confirm decompression following endoscopic endonasal approach for cervicomedullary compression.

Authors:  Abhiram Gande; Matthew J Tormenti; Maria Koutourousiou; Alessandro Paluzzi; Juan C Fernendez-Miranda; Carl H Snydermnan; Paul A Gardner
Journal:  J Neurol Surg B Skull Base       Date:  2013-01-02
View more