Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation.

E R Chafizadeh1, W A Zoghbi.   

Abstract

To test whether the continuity equation can be applied to the noninvasive assessment of prosthetic aortic valve function, Doppler echocardiography was performed in 67 patients (mean age, 58 +/- 14 years) within 10 +/- 6 days after valve replacement with St. Jude Medical valves. All patients were clinically stable and without evidence of valve dysfunction. Valve size ranged from 19 to 31 mm, and ejection fraction ranged from 30% to 75%. With the parasternal long-axis view, the left ventricular outflow diameter measured just proximal to the prosthetic valve correlated well with valve size (r = 0.92). Doppler-derived maximal gradients ranged from 9 to 71 mm Hg. Effective prosthetic aortic valve area by the continuity equation ranged between 0.73 cm2 for a 19-mm valve and 4.23 cm2 for a 31-mm valve. With analysis of variance, effective orifice area differentiated various valve sizes (p less than 10(-14)) better than did gradients alone (p = 0.003) and correlated better with actual valve orifice area (r = 0.83 versus - 0.40). A Doppler velocity index, the ratio of peak velocity in the left ventricular outflow to that of the aortic jet, averaged 0.41 +/- 0.09 and was less dependent on valve size (r = 0.43). Thus, the continuity equation can be applied to the assessment of prosthetic St. Jude valves in the aortic position. By accounting for flow through the valve, it provides an improved assessment over the sole use of gradients in the evaluation of prosthetic valve function.

Entities:  

Mesh:

Year:  1991        PMID: 1984881     DOI: 10.1161/01.cir.83.1.213

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  11 in total

1.  [Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve].

Authors:  T Shimabukuro; Y Takeuchi; A Gomi; H Nakatani; Y Suda; K Kono; N Nagano
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-12

2.  Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study.

Authors:  Rune Haaverstad; Nicola Vitale; Asbjørn Karevold; Giangiuseppe Cappabianca; Arve Tromsdal; Peter Skov Olsen; Lars Köber; Halfdan Ihlen; Kjell Arne Rein; Jan L Svennevig
Journal:  Heart       Date:  2006-10-25       Impact factor: 5.994

3.  Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paper.

Authors:  J Chambers; A Fraser; P Lawford; P Nihoyannopoulos; I Simpson
Journal:  Br Heart J       Date:  1994-04

4.  Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status.

Authors:  Denis Bouchard; Frédéric Vanden Eynden; Philippe Demers; Louis P Perrault; Michel Carrier; Raymond Cartier; Arsène J Basmadjian; Michel Pellerin
Journal:  Can J Cardiol       Date:  2010-12       Impact factor: 5.223

5.  Haemodynamic performance of aortic pericardial bioprostheses and bileaflet prostheses at rest and during exercise: implications for the surgical management of patients with small aortic roots.

Authors:  J R González-Juanatey; M V Fernández; F G Sampedro; J M García-Acuña; J B García-Bengoechea; A A Cendon; M G de La Peña
Journal:  Heart       Date:  1999-08       Impact factor: 5.994

6.  Stentless bioprostheses have ideal haemodynamics, even in the small aortic root.

Authors:  L H Baur; Y Houdas; K H Peels; J Braun; B van Straten; A Prat; A P Kappetein; M Wolters-Geldoff; E E van der Wall; A V Bruschke; H A Huysmans
Journal:  Int J Card Imaging       Date:  2000-10

Review 7.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

8.  Left ventricular dynamics after aortic valve replacement: a long-term, combined radionuclide angiographic and ultrasonographic study.

Authors:  C S Masotti; P Bonfranceschi; G Rusticali; F Rusticali; A Pierangeli
Journal:  Tex Heart Inst J       Date:  1992

9.  Patient-prosthesis mismatch increases the mean platelet volume in patients with aortic valve replacement.

Authors:  Huseyin Bayram; Mete Hidiroglu; Levent Cetin; Omer Faruk Cicek; Aslihan Kucuker; Emrah Uguz; Kemal Esref Erdogan; Erol Sener
Journal:  Surg Today       Date:  2014-05-29       Impact factor: 2.549

10.  High transvalvular pressure gradients on intraoperative transesophageal echocardiography after aortic valve replacement: what does it mean?

Authors:  A Parnell; J Swanevelder
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009
View more