Literature DB >> 19840726

Accuracy of the Welch Allyn SureSight for measurement of magnitude of astigmatism in 3- to 7-year-old children.

Erin M Harvey1, Velma Dobson, Joseph M Miller, Candice E Clifford-Donaldson, Tina K Green, Dawn H Messer, Katherine A Garvey.   

Abstract

PURPOSE: To evaluate the accuracy of the Welch Allyn SureSight in noncycloplegic measurements of astigmatism as compared to cycloplegic Retinomax K+ autorefractor measurements of astigmatism in children from a Native American population with a high prevalence of high astigmatism.
METHODS: Data are reported for 825 3- to 7-year-old children with no ocular abnormalities. Each child had a Retinomax K+ cycloplegic measurement of right eye astigmatism with a confidence rating > or =8 and 3 attempts to obtain a SureSight measurement on the right eye.
RESULTS: SureSight measurement success rates did not differ significantly across age or measurement confidence rating (<6 vs > or =6). Ninety-six percent of children had at least 1 measurement (any confidence), and 89% had at least 1 measurement with confidence at the manufacturer's recommended value (> or =6). Overall, the SureSight tended to overestimate astigmatism. If the SureSight measurement had any dioptric value (0.00 D to 3.00 D), astigmatism of 2.00 D or less was likely to be present. If the SureSight showed astigmatism beyond the instrument's dioptric range (>3.00 D), Retinomax K+ measurements indicated that >2.00 D of astigmatism was present in 136 of 157 (86.6%). In cooperative children for whom the SureSight would not give a reading, 32 of 34 (94%) had >3.00 D of astigmatism.
CONCLUSIONS: The SureSight does not provide an accurate, quantitative measure of amount of astigmatism. However, it does allow accurate categorization of amount of astigmatism as < or =2.00 D, >2.00 D, or >3.00 D, and it has high measurement success rate in young children.

Entities:  

Mesh:

Year:  2009        PMID: 19840726      PMCID: PMC2765412          DOI: 10.1016/j.jaapos.2009.08.013

Source DB:  PubMed          Journal:  J AAPOS        ISSN: 1091-8531            Impact factor:   1.220


  21 in total

1.  Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children.

Authors:  S W Chat; M H Edwards
Journal:  Ophthalmic Physiol Opt       Date:  2001-03       Impact factor: 3.117

2.  Accuracy of noncycloplegic autorefraction in school-age children in China.

Authors:  Jialiang Zhao; Jin Mao; Rong Luo; Fengrong Li; Gopal P Pokharel; Leon B Ellwein
Journal:  Optom Vis Sci       Date:  2004-01       Impact factor: 1.973

3.  Cycloplegic autorefraction results in pre-school children using the Nikon Retinomax Plus and the Welch Allyn SureSight.

Authors:  Gregg Steele; Dennis Ireland; Sandra Block
Journal:  Optom Vis Sci       Date:  2003-08       Impact factor: 1.973

4.  Testing young infants with the Welch Allyn suresight non-cycloplegic autorefractor.

Authors:  Russell J Adams; Susan M Dalton; Angela M Murphy; Heather L Hall; Mary L Courage
Journal:  Ophthalmic Physiol Opt       Date:  2002-11       Impact factor: 3.117

5.  Comparison of cycloplegic and noncycloplegic retinoscopy in Chinese pre-school children.

Authors:  O Y Chan; M Edwards
Journal:  Optom Vis Sci       Date:  1994-05       Impact factor: 1.973

6.  Visual acuity screening versus noncycloplegic autorefraction screening for astigmatism in Native American preschool children.

Authors:  J M Miller; E M Harvey; V Dobson
Journal:  J AAPOS       Date:  1999-06       Impact factor: 1.220

7.  Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients.

Authors:  Thilo Schimitzek; Wolfgang Wesemann
Journal:  J Cataract Refract Surg       Date:  2002-09       Impact factor: 3.351

8.  Clinical comparison of the Welch Allyn SureSight handheld autorefractor versus cycloplegic autorefraction and retinoscopic refraction.

Authors:  Joseph D Iuorno; William D Grant; Léon-Paul Noël
Journal:  J AAPOS       Date:  2004-04       Impact factor: 1.220

9.  The manifestation of noncycloplegic refractive state in pre-school children is dependent on autorefractor design.

Authors:  R Suryakumar; W R Bobier
Journal:  Optom Vis Sci       Date:  2003-08       Impact factor: 1.973

10.  Comparison of preschool vision screening tests as administered by licensed eye care professionals in the Vision In Preschoolers Study.

Authors:  Paulette Schmidt; Maureen Maguire; Velma Dobson; Graham Quinn; Elise Ciner; Lynn Cyert; Marjean Taylor Kulp; Bruce Moore; Deborah Orel-Bixler; Maryann Redford; Gui-shuang Ying
Journal:  Ophthalmology       Date:  2004-04       Impact factor: 12.079

View more
  9 in total

1.  Comparison of the Retinomax and Palm-AR Auto-Refractors: a pilot study.

Authors:  Elise Ciner; Ashanti Carter; Gui-Shuang Ying; Maureen Maguire; Marjean Taylor Kulp
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

2.  Amblyopia in astigmatic infants and toddlers.

Authors:  Velma Dobson; Erin M Harvey; Candice E Clifford-Donaldson; Tina K Green; Joseph M Miller
Journal:  Optom Vis Sci       Date:  2010-05       Impact factor: 1.973

3.  Beyond screening for risk factors: objective detection of strabismus and amblyopia.

Authors:  Reed M Jost; Susan E Yanni; Cynthia L Beauchamp; David R Stager; David Stager; Lori Dao; Eileen E Birch
Journal:  JAMA Ophthalmol       Date:  2014-07       Impact factor: 7.389

4.  Impact of confidence number on accuracy of the SureSight Vision Screener.

Authors: 
Journal:  Optom Vis Sci       Date:  2010-02       Impact factor: 1.973

5.  Utility of an open field Shack-Hartmann aberrometer for measurement of refractive error in infants and young children.

Authors:  Erin M Harvey; Joseph M Miller; Jim Schwiegerling
Journal:  J AAPOS       Date:  2013-10       Impact factor: 1.220

6.  Intertester agreement in refractive error measurements.

Authors:  Jiayan Huang; Maureen G Maguire; Elise Ciner; Marjean T Kulp; Graham E Quinn; Deborah Orel-Bixler; Lynn A Cyert; Bruce Moore; Gui-Shuang Ying
Journal:  Optom Vis Sci       Date:  2013-10       Impact factor: 1.973

7.  Development of refractive error in children treated for retinopathy of prematurity with anti-vascular endothelial growth factor (anti-VEGF) agents: A meta-analysis and systematic review.

Authors:  Qing-Qing Tan; Stephen P Christiansen; Jingyun Wang
Journal:  PLoS One       Date:  2019-12-02       Impact factor: 3.240

Review 8.  A Systematic Review of Current Teleophthalmology Services in New Zealand Compared to the Four Comparable Countries of the United Kingdom, Australia, United States of America (USA) and Canada.

Authors:  Liam Walsh; Sheng Chiong Hong; Renoh Johnson Chalakkal; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2021-10-04

9.  Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study.

Authors:  Qi Yan; Rui Li; YingXiao Qian; Xiao Lin; Hui Zhu; Yue Wang; Xiaoyan Zhao; Xiaohan Zhang; Qigang Sun; Qingfeng Hao; Haohai Tong; Yue Zhu; Zhitong Li; Yan Zhu; Hu Liu; Dan Huang
Journal:  Front Public Health       Date:  2022-09-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.