Literature DB >> 12917576

Cycloplegic autorefraction results in pre-school children using the Nikon Retinomax Plus and the Welch Allyn SureSight.

Gregg Steele1, Dennis Ireland, Sandra Block.   

Abstract

PURPOSE: Early detection and treatment of amblyogenic conditions such as high refractive errors and anisometropia can help prevent the development of amblyopia. The traditional gold standard for the determination of refractive error in pre-school children is retinoscopy. Difficulties with retinoscopy in pre-school children have led to the development of autorefractors that can be free of operator bias and can be used by lay individuals. The Nikon Retinomax Plus handheld autorefractor has proven to be reliable for quick and accurate assessments of refractive errors in children. The Welch Allyn SureSight Vision Screener is a relatively new handheld autorefractor. The present study compares the results of measurements with the Retinomax Plus and the SureSight to the results of cycloplegic retinoscopy in pre-school children.
METHODS: Thirty-five children ranging in age from 3 to 5 years old were subjects. Any subjects with strabismus, amblyopia, nystagmus, or ocular disease were excluded. Refractive error was assessed 30 min after the application of a cycloplegic spray.
RESULTS: Both autorefractors showed moderate agreement with cycloplegic retinoscopy results for measurement of spherical equivalent and cylinder power. In addition, the SureSight and the Retinomax Plus sphere and cylinder results showed moderate agreement with each other. Although the mean differences of the spherical equivalents determined were minimal, the 95% confidence intervals were large, which limits the value of the data obtained from each instrument.
CONCLUSIONS: Even though the Retinomax Plus and the SureSight appear to agree with each other and with the results of cycloplegic retinoscopy for determining sphere and cylinder power, interpretation of the data should be considered as screening only because the actual magnitude of sphere and cylinder may vary from the actual magnitude. These results suggest that either device may be useful only as screening tools for assessing refractive error in pre-school children.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12917576     DOI: 10.1097/00006324-200308000-00010

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  22 in total

1.  Comparison of the Retinomax and Palm-AR Auto-Refractors: a pilot study.

Authors:  Elise Ciner; Ashanti Carter; Gui-Shuang Ying; Maureen Maguire; Marjean Taylor Kulp
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

2.  Accuracy of noncycloplegic retinoscopy, retinomax autorefractor, and SureSight vision screener for detecting significant refractive errors.

Authors:  Marjean Taylor Kulp; Gui-Shuang Ying; Jiayan Huang; Maureen Maguire; Graham Quinn; Elise B Ciner; Lynn A Cyert; Deborah A Orel-Bixler; Bruce D Moore
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-06       Impact factor: 4.799

3.  Average gradient of Zernike polynomials over polygons.

Authors:  Vyas Akondi; Alfredo Dubra
Journal:  Opt Express       Date:  2020-06-22       Impact factor: 3.894

4.  The relationship between anisometropia, patient age, and the development of amblyopia.

Authors:  Sean P Donahue
Journal:  Trans Am Ophthalmol Soc       Date:  2005

5.  Hyperopia and educational attainment in a primary school cohort.

Authors:  W R Williams; A H A Latif; L Hannington; D R Watkins
Journal:  Arch Dis Child       Date:  2005-02       Impact factor: 3.791

6.  ROC analysis of the accuracy of Noncycloplegic retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for preschool vision screening.

Authors:  Gui-shuang Ying; Maureen Maguire; Graham Quinn; Marjean Taylor Kulp; Lynn Cyert
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-12-28       Impact factor: 4.799

7.  Receding and disparity cues aid relaxation of accommodation.

Authors:  Anna M Horwood; Patricia M Riddell
Journal:  Optom Vis Sci       Date:  2009-11       Impact factor: 1.973

8.  Accuracy of the Welch Allyn SureSight for measurement of magnitude of astigmatism in 3- to 7-year-old children.

Authors:  Erin M Harvey; Velma Dobson; Joseph M Miller; Candice E Clifford-Donaldson; Tina K Green; Dawn H Messer; Katherine A Garvey
Journal:  J AAPOS       Date:  2009-10       Impact factor: 1.220

9.  Anisometropia prevalence in a highly astigmatic school-aged population.

Authors:  Velma Dobson; Erin M Harvey; Joseph M Miller; Candice E Clifford-Donaldson
Journal:  Optom Vis Sci       Date:  2008-07       Impact factor: 1.973

10.  Impact of confidence number on accuracy of the SureSight Vision Screener.

Authors: 
Journal:  Optom Vis Sci       Date:  2010-02       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.