Literature DB >> 15051194

Comparison of preschool vision screening tests as administered by licensed eye care professionals in the Vision In Preschoolers Study.

Paulette Schmidt1, Maureen Maguire, Velma Dobson, Graham Quinn, Elise Ciner, Lynn Cyert, Marjean Taylor Kulp, Bruce Moore, Deborah Orel-Bixler, Maryann Redford, Gui-shuang Ying.   

Abstract

PURPOSE: To compare 11 preschool vision screening tests administered by licensed eye care professionals (LEPs; optometrists and pediatric ophthalmologists).
DESIGN: Multicenter, cross-sectional study. PARTICIPANTS: A sample (N = 2588) of 3- to 5-year-old children enrolled in Head Start was selected to over-represent children with vision problems.
METHODS: Certified LEPs administered 11 commonly used or commercially available screening tests. Results from a standardized comprehensive eye examination were used to classify children with respect to 4 targeted conditions: amblyopia, strabismus, significant refractive error, and unexplained reduced visual acuity (VA). MAIN OUTCOME MEASURES: Sensitivity for detecting children with > or =1 targeted conditions at selected levels of specificity was the primary outcome measure. Sensitivity also was calculated for detecting conditions grouped into 3 levels of importance.
RESULTS: At 90% specificity, sensitivities of noncycloplegic retinoscopy (NCR) (64%), the Retinomax Autorefractor (63%), SureSight Vision Screener (63%), and Lea Symbols test (61%) were similar. Sensitivities of the Power Refractor II (54%) and HOTV VA test (54%) were similar to each other. Sensitivities of the Random Dot E stereoacuity (42%) and Stereo Smile II (44%) tests were similar to each other and lower (P<0.0001) than the sensitivities of NCR, the 2 autorefractors, and the Lea Symbols test. The cover-uncover test had very low sensitivity (16%) but very high specificity (98%). Sensitivity for conditions considered the most important to detect was 80% to 90% for the 2 autorefractors and NCR. Central interpretations for the MTI and iScreen photoscreeners each yielded 94% specificity and 37% sensitivity. At 94% specificity, the sensitivities were significantly better for NCR, the 2 autorefractors, and the Lea Symbols VA test than for the 2 photoscreeners for detecting > or =1 targeted conditions and for detecting the most important conditions.
CONCLUSIONS: Screening tests administered by LEPs vary widely in performance. With 90% specificity, the best tests detected only two thirds of children having > or =1 targeted conditions, but nearly 90% of children with the most important conditions. The 2 tests that use static photorefractive technology were less accurate than 3 tests that assess refractive error in other ways. These results have important implications for screening preschool-aged children.

Entities:  

Mesh:

Year:  2004        PMID: 15051194     DOI: 10.1016/j.ophtha.2004.01.022

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  79 in total

1.  Comparison of the Retinomax and Palm-AR Auto-Refractors: a pilot study.

Authors:  Elise Ciner; Ashanti Carter; Gui-Shuang Ying; Maureen Maguire; Marjean Taylor Kulp
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

Review 2.  Vision screening in preschool children: do the data support universal screening?

Authors:  Wolf A Lagrèze
Journal:  Dtsch Arztebl Int       Date:  2010-07-12       Impact factor: 5.594

3.  Two-dimensional simulation of eccentric photorefraction images for ametropes: factors influencing the measurement.

Authors:  Yifei Wu; Larry N Thibos; T Rowan Candy
Journal:  Ophthalmic Physiol Opt       Date:  2018-05-07       Impact factor: 3.117

4.  Preschool vision screening in pediatric practices.

Authors:  Alex R Kemper; Sarah J Clark
Journal:  Clin Pediatr (Phila)       Date:  2006-04       Impact factor: 1.168

5.  Artificial intelligence techniques for automatic screening of amblyogenic factors.

Authors:  Jonathan Van Eenwyk; Arvin Agah; Joseph Giangiacomo; Gerhard Cibis
Journal:  Trans Am Ophthalmol Soc       Date:  2008

6.  Preschool vision screening by family physicians.

Authors:  Alex R Kemper; Sarah J Clark
Journal:  J Pediatr Ophthalmol Strabismus       Date:  2007 Jan-Feb       Impact factor: 1.402

7.  Global motion perception is associated with motor function in 2-year-old children.

Authors:  Benjamin Thompson; Christopher J D McKinlay; Arijit Chakraborty; Nicola S Anstice; Robert J Jacobs; Nabin Paudel; Tzu-Ying Yu; Judith M Ansell; Trecia A Wouldes; Jane E Harding
Journal:  Neurosci Lett       Date:  2017-08-31       Impact factor: 3.046

8.  A computerized resolution visual acuity test in preschool and school age children.

Authors:  Ying-Yan Qin; Zhen-Zhen Liu; Li-Yuan Zhu; Xuan Bao; Fu-Rong Luo; Yi-Zhi Liu; Young Tsau; Ming-Xing Wu
Journal:  Int J Ophthalmol       Date:  2020-02-18       Impact factor: 1.779

9.  Stereoacuity of preschool children with and without vision disorders.

Authors:  Elise B Ciner; Gui-Shuang Ying; Marjean Taylor Kulp; Maureen G Maguire; Graham E Quinn; Deborah Orel-Bixler; Lynn A Cyert; Bruce Moore; Jiayan Huang
Journal:  Optom Vis Sci       Date:  2014-03       Impact factor: 1.973

10.  Outcome at 2 Years after Dextrose Gel Treatment for Neonatal Hypoglycemia: Follow-Up of a Randomized Trial.

Authors:  Deborah L Harris; Jane M Alsweiler; Judith M Ansell; Gregory D Gamble; Benjamin Thompson; Trecia A Wouldes; Tzu-Ying Yu; Jane E Harding
Journal:  J Pediatr       Date:  2015-11-21       Impact factor: 4.406

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.