| Literature DB >> 7811442 |
L O Lerman1, M R Bell, V Lahera, J A Rumberger, P F Sheedy, A Sanchez Fueyo, J C Romero.
Abstract
Alterations in renal blood flow distribution may occur in a variety of pathophysiologic situations; however, quantification of global and regional renal blood flows has been limited because of the lack of reliable, noninvasive techniques. To determine the feasibility of flow measurements with electron-beam computed tomography (EBCT), six anesthetized dogs were scanned by EBCT during basal conditions, after renal vasodilation, and at recovery. Flow (mL/min/cm3 tissue) was calculated from EBCT-derived time-density curves using three different algorithms and compared with simultaneously obtained electromagnetic flow (EMF) probe measurements after indexing to EBCT-derived renal volume. EBCT-determined flow correlated well with EMF measurements regardless of the algorithm used. An algorithm using the area under the time-density curve was concluded to be the most suitable for calculation of renal blood flow; it correlated with EMF as EBCT flow = 44.5 + 1.05 EMF (r = 0.885, SEE = 31.2 mL/min, P < .0001). Consistent overestimation of flow by EBCT resulted probably from retention of contrast media in the renal parenchyma. EMF showed an increase of 20 +/- 10% in renal blood flow after vasodilation. EBCT-derived global, cortical, and medullary flows increased by 33.8 +/- 10.3%, 24.8 +/- 17.8%, and 99.0 +/- 73.8%, respectively. In conclusion, EBCT was found feasible for credible quantitation of renal blood flow in the physiologic range studied.Entities:
Mesh:
Substances:
Year: 1994 PMID: 7811442 DOI: 10.1093/ajh/7.9.829
Source DB: PubMed Journal: Am J Hypertens ISSN: 0895-7061 Impact factor: 2.689