PURPOSE: To design and compare an eight-channel phased array (PA) coil for carotid imaging to an established four-channel PA design at 3T. MATERIALS AND METHODS: An eight-channel PA (8PA) coil was designed specifically for imaging the carotid bifurcation and compared with the existing four-channel (4PA) design using a phantom and by in vivo black-blood magnetic resonance imaging (MRI). The 8PA and 4PA were compared in terms of coverage, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). RESULTS: The 8PA showed up to 1.7-fold improvement in SNR at a depth of 3.5 cm and greater longitudinal coverage at a given SNR on a phantom. The 8PA showed improved vessel wall SNR for high spatial resolution (0.63 mm(2)) PD, T1, and T2 (1.7, 1.7, 1.6 times, respectively; P <or= 0.002) and improved CNR (1.7, 1.6, 1.5 times, respectively; P <or= 0.002). Ultrahigh-resolution (0.27 mm(2)) T1-weighted images showed better SNR and CNR (1.4 times, P <or= 0.0001) on 8PA compared to 4PA. CONCLUSION: Carotid imaging studies may benefit from the improved SNR and larger coverage provided by use of the 8PA.
PURPOSE: To design and compare an eight-channel phased array (PA) coil for carotid imaging to an established four-channel PA design at 3T. MATERIALS AND METHODS: An eight-channel PA (8PA) coil was designed specifically for imaging the carotid bifurcation and compared with the existing four-channel (4PA) design using a phantom and by in vivo black-blood magnetic resonance imaging (MRI). The 8PA and 4PA were compared in terms of coverage, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). RESULTS: The 8PA showed up to 1.7-fold improvement in SNR at a depth of 3.5 cm and greater longitudinal coverage at a given SNR on a phantom. The 8PA showed improved vessel wall SNR for high spatial resolution (0.63 mm(2)) PD, T1, and T2 (1.7, 1.7, 1.6 times, respectively; P <or= 0.002) and improved CNR (1.7, 1.6, 1.5 times, respectively; P <or= 0.002). Ultrahigh-resolution (0.27 mm(2)) T1-weighted images showed better SNR and CNR (1.4 times, P <or= 0.0001) on 8PA compared to 4PA. CONCLUSION: Carotid imaging studies may benefit from the improved SNR and larger coverage provided by use of the 8PA.
Authors: T Saam; M S Ferguson; V L Yarnykh; N Takaya; D Xu; N L Polissar; T S Hatsukami; C Yuan Journal: Arterioscler Thromb Vasc Biol Date: 2004-11-04 Impact factor: 8.311
Authors: Jianming Cai; Thomas S Hatsukami; Marina S Ferguson; William S Kerwin; Tobias Saam; Baocheng Chu; Norihide Takaya; Nayak L Polissar; Chun Yuan Journal: Circulation Date: 2005-11-21 Impact factor: 29.690
Authors: Mark Fisher; Annlia Paganini-Hill; Aldana Martin; Michele Cosgrove; James F Toole; Henry J M Barnett; John Norris Journal: Stroke Date: 2005-01-13 Impact factor: 7.914
Authors: R A Trivedi; J U-King-Im; M J Graves; J Horsley; M Goddard; P J Kirkpatrick; J H Gillard Journal: Eur J Vasc Endovasc Surg Date: 2004-08 Impact factor: 7.069
Authors: Michael J Beck; Dennis L Parker; Bradley D Bolster; Seong-Eun Kim; J Scott McNally; Gerald S Treiman; J Rock Hadley Journal: Magn Reson Med Date: 2017-02-10 Impact factor: 4.668
Authors: Jinnan Wang; Peter Börnert; Huilin Zhao; Daniel S Hippe; Xihai Zhao; Niranjan Balu; Marina S Ferguson; Thomas S Hatsukami; Jianrong Xu; Chun Yuan; William S Kerwin Journal: Magn Reson Med Date: 2012-03-22 Impact factor: 4.668
Authors: Laura A Fitzpatrick; Nadav Berkovitz; Marlise P Dos Santos; Nevin Majeed; Rafael Glikstein; Santanu Chakraborty; John P Veinot; Grant Stotts; Alain Berthiaume; Robert Chatelain Journal: Neuroradiol J Date: 2017-01-10
Authors: Diederik F van Wijk; Aart C Strang; Raphael Duivenvoorden; Dirk-Jan F Enklaar; Rob J van der Geest; John J P Kastelein; Eric de Groot; Erik S G Stroes; Aart J Nederveen Journal: MAGMA Date: 2013-09-18 Impact factor: 2.310
Authors: Wei Yu; Hunter R Underhill; Marina S Ferguson; Daniel S Hippe; Thomas S Hatsukami; Chun Yuan; Baocheng Chu Journal: J Cardiovasc Magn Reson Date: 2009-08-18 Impact factor: 5.364