Literature DB >> 22777692

Increased vessel depiction of the carotid bifurcation with a specialized 16-channel phased array coil at 3T.

Quinn Tate1, Seong-Eun Kim, Gerald Treiman, Dennis L Parker, J Rock Hadley.   

Abstract

The purpose of this work was to design and construct a multichannel receive-only radiofrequency coil for 3T magnetic resonance imaging of the human carotid artery and bifurcation with optimized signal-to-noise ratio (SNR) in the carotid vessels along the full extent of the neck. A neck phantom designed to match the anatomy of a subject with a neck representing the body habitus often seen in subjects with carotid arterial disease was constructed. Sixteen circular coil elements were arranged on a semirigid fiberglass former that closely fit the shape of the phantom, resulting in a 16-channel bilateral phased array coil. Comparisons were made between this coil and a typical 4-channel carotid coil in a study of 10 carotid vessels in five healthy volunteers. The 16-channel carotid coil showed a 73% average improvement in SNR at the carotid bifurcation. This coil also maintained an SNR greater than the peak SNR of the 4-channel coil over a vessel length of 10 cm. The resulting increase in SNR improved vessel depiction of the carotid arteries over an extended field of view, and demonstrated better image quality for higher parallel imaging reduction factors compared to the 4-channel coil.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22777692      PMCID: PMC3556366          DOI: 10.1002/mrm.24380

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Geometrical optimization of a phased array coil for high-resolution MR imaging of the carotid arteries.

Authors:  A Liffers; H H Quick; C U Herborn; H Ermert; M E Ladd
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

2.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

3.  Relative RF coil performance in carotid imaging.

Authors:  J Rock Hadley; John A Roberts; K Craig Goodrich; Henry R Buswell; Dennis L Parker
Journal:  Magn Reson Imaging       Date:  2005-06       Impact factor: 2.546

4.  32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry.

Authors:  G C Wiggins; C Triantafyllou; A Potthast; A Reykowski; M Nittka; L L Wald
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

5.  Noise figure limits for circular loop MR coils.

Authors:  Ananda Kumar; William A Edelstein; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

Review 6.  Current imaging modalities to visualize vulnerability within the atherosclerotic carotid plaque.

Authors:  Bas M Wallis de Vries; Gooitzen M van Dam; René A Tio; Jan-Luuk Hillebrands; Riemer H J A Slart; Clark J Zeebregts
Journal:  J Vasc Surg       Date:  2008-09-19       Impact factor: 4.268

7.  Surface coil phased arrays for high-resolution imaging of the carotid arteries.

Authors:  C E Hayes; C M Mathis; C Yuan
Journal:  J Magn Reson Imaging       Date:  1996 Jan-Feb       Impact factor: 4.813

Review 8.  Theory and application of array coils in MR spectroscopy.

Authors:  S M Wright; L L Wald
Journal:  NMR Biomed       Date:  1997-12       Impact factor: 4.044

9.  Importance of emboli from carotid bifurcation in pathogenesis of cerebral ischemic attacks.

Authors:  W S Moore; A D Hall
Journal:  Arch Surg       Date:  1970-12

Review 10.  Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries.

Authors:  S Glagov; C Zarins; D P Giddens; D N Ku
Journal:  Arch Pathol Lab Med       Date:  1988-10       Impact factor: 5.534

View more
  6 in total

1.  Wall shear stress distribution at the carotid bifurcation: influence of eversion carotid endarterectomy.

Authors:  A Harloff; S Berg; A J Barker; J Schöllhorn; M Schumacher; C Weiller; M Markl
Journal:  Eur Radiol       Date:  2013-06-29       Impact factor: 5.315

2.  Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system.

Authors:  Michael J Beck; Dennis L Parker; Bradley D Bolster; Seong-Eun Kim; J Scott McNally; Gerald S Treiman; J Rock Hadley
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

Review 3.  Three-Dimensional Carotid Plaque MR Imaging.

Authors:  Chun Yuan; Dennis L Parker
Journal:  Neuroimaging Clin N Am       Date:  2015-10-19       Impact factor: 2.264

4.  Three-dimensional dynamic contrast enhanced imaging of the carotid artery with direct arterial input function measurement.

Authors:  Jason Mendes; Dennis L Parker; Scott McNally; Ed DiBella; Bradley D Bolster; Gerald S Treiman
Journal:  Magn Reson Med       Date:  2013-12-24       Impact factor: 4.668

5.  Vitamin D and Vulnerable Carotid Plaque.

Authors:  J S McNally; T M Burton; B W Aldred; S-E Kim; M S McLaughlin; L B Eisenmenger; G J Stoddard; J J Majersik; D V Miller; G S Treiman; D L Parker
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-16       Impact factor: 3.825

Review 6.  Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage.

Authors:  J Scott McNally; Seong-Eun Kim; Jason Mendes; J Rock Hadley; Akihiko Sakata; Adam H De Havenon; Gerald S Treiman; Dennis L Parker
Journal:  Magn Reson Insights       Date:  2017-03-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.