Literature DB >> 12876724

Geometrical optimization of a phased array coil for high-resolution MR imaging of the carotid arteries.

A Liffers1, H H Quick, C U Herborn, H Ermert, M E Ladd.   

Abstract

The geometry of an RF phased-array receiving coil for high-resolution MRI of the carotid artery, particularly the bifurcation, was optimized with respect to signal-to-noise ratio (SNR). A simulation tool was developed to determine homogeneity, sensitivity, and SNR for a given imaging situation. The algorithm takes into account the coil geometry, the parameters of the measured object, and the imaging parameters of the pulse sequence. The coil with the optimum geometry was implemented as a receive-only coil for 1.5 T and comparative SNR measurements with different coils were performed. The experimental SNR measurements verified the simulations. The optimized carotid artery phased array offered the best SNR over the desired field of view. In vivo high-resolution MRI of the carotid arteries of healthy volunteers and patients with known stenosis was conducted with the optimized phased array coil. The capability of the phased array coil for resolving components within the carotid artery walls is demonstrated. Magn Reson Med 50:439-443, 2003. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12876724     DOI: 10.1002/mrm.10526

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Increased vessel depiction of the carotid bifurcation with a specialized 16-channel phased array coil at 3T.

Authors:  Quinn Tate; Seong-Eun Kim; Gerald Treiman; Dennis L Parker; J Rock Hadley
Journal:  Magn Reson Med       Date:  2012-07-06       Impact factor: 4.668

2.  High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla.

Authors:  Seshasailaja Anumula; Hee Kwon Song; Alexander C Wright; Felix W Wehrli
Journal:  Acad Radiol       Date:  2005-12       Impact factor: 3.173

Review 3.  Advanced techniques for MRI of atherosclerotic plaque.

Authors:  William S Kerwin; Gador Canton
Journal:  Top Magn Reson Imaging       Date:  2009-08

4.  Improvements in carotid plaque imaging using a new eight-element phased array coil at 3T.

Authors:  Niranjan Balu; Vasily L Yarnykh; Joshua Scholnick; Baocheng Chu; Chun Yuan; Cecil Hayes
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

5.  Comparison of four MR carotid surface coils at 3T.

Authors:  Qinwei Zhang; Bram F Coolen; Sandra van den Berg; Gyula Kotek; Debra S Rivera; Dennis W J Klomp; Gustav J Strijkers; Aart J Nederveen
Journal:  PLoS One       Date:  2019-03-04       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.