Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study.

Kristin D Zhao, Ephraim I Ben-Abraham, Dixon J Magnuson, Jon J Camp, Lawrence J Berglund, Kai-Nan An, Gert Bronfort, Ralph E Gay.   

Abstract

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.

Entities:  

Mesh:

Year:  2016        PMID: 26974192      PMCID: PMC4843847          DOI: 10.1115/1.4032995

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  27 in total

1.  Segmental lumbar rotation in patients with discogenic low back pain during functional weight-bearing activities.

Authors:  Peter G Passias; Shaobai Wang; Michal Kozanek; Qun Xia; Weishi Li; Brian Grottkau; Kirkham B Wood; Guoan Li
Journal:  J Bone Joint Surg Am       Date:  2011-01-05       Impact factor: 5.284

2.  Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Authors:  Michael J Bey; Roger Zauel; Stephanie K Brock; Scott Tashman
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

3.  Capturing three-dimensional in vivo lumbar intervertebral joint kinematics using dynamic stereo-X-ray imaging.

Authors:  Ameet K Aiyangar; Liying Zheng; Scott Tashman; William J Anderst; Xudong Zhang
Journal:  J Biomech Eng       Date:  2014-01       Impact factor: 2.097

4.  Kinematic analysis of dynamic lumbar motion in patients with lumbar segmental instability using digital videofluoroscopy.

Authors:  Amir Ahmadi; Nader Maroufi; Hamid Behtash; Hajar Zekavat; Mohamad Parnianpour
Journal:  Eur Spine J       Date:  2009-11       Impact factor: 3.134

5.  Dynamic motion study of the whole lumbar spine by videofluoroscopy.

Authors:  A Okawa; K Shinomiya; H Komori; T Muneta; Y Arai; O Nakai
Journal:  Spine (Phila Pa 1976)       Date:  1998-08-15       Impact factor: 3.468

6.  The quantification of low back disorder using motion measures. Methodology and validation.

Authors:  W S Marras; S A Ferguson; P Gupta; S Bose; M Parnianpour; J Y Kim; R R Crowell
Journal:  Spine (Phila Pa 1976)       Date:  1999-10-15       Impact factor: 3.468

7.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques.

Authors:  Daniel L Miranda; Joel B Schwartz; Andrew C Loomis; Elizabeth L Brainerd; Braden C Fleming; Joseph J Crisco
Journal:  J Biomech Eng       Date:  2011-12       Impact factor: 2.097

8.  A new technique for digital fluoroscopic video assessment of sagittal plane lumbar spine motion.

Authors:  Deydre S Teyhen; Timothy W Flynn; Alan C Bovik; Lawrence D Abraham
Journal:  Spine (Phila Pa 1976)       Date:  2005-07-15       Impact factor: 3.468

9.  Accuracy and precision of a method to study kinematics of the temporomandibular joint: combination of motion data and CT imaging.

Authors:  Evre Baltali; Kristin D Zhao; Matthew F Koff; Eugene E Keller; Kai-Nan An
Journal:  J Biomech       Date:  2008-07-09       Impact factor: 2.712

10.  Quantification of a meaningful change in low back functional impairment.

Authors:  Sue A Ferguson; William S Marras; Deborah L Burr; Stephen Woods; Ehud Mendel; Purnendu Gupta
Journal:  Spine (Phila Pa 1976)       Date:  2009-09-01       Impact factor: 3.468

View more
  4 in total

1.  OPF/PMMA cage system as an alternative approach for the treatment of vertebral corpectomy.

Authors:  Asghar Rezaei; Hugo Giambini; Alan L Miller; Xifeng Liu; Benjamin D Elder; Michael J Yaszemski; Lichun Lu
Journal:  Appl Sci (Basel)       Date:  2020-10-02       Impact factor: 2.679

2.  Does the neutral zone quantification method matter? Efficacy of evaluating neutral zone during destabilization and restabilization in human spine implant testing.

Authors:  T Di Pauli von Treuheim; L Zengerle; A C Hecht; J C Iatridis; H J Wilke
Journal:  J Biomech       Date:  2021-09-21       Impact factor: 2.712

3.  Definition of Normal Vertebral Morphometry Using NHANES-II Radiographs.

Authors:  John A Hipp; Trevor F Grieco; Patrick Newman; Charles A Reitman
Journal:  JBMR Plus       Date:  2022-09-27

4.  Analysis of translation and angular motion in loaded and unloaded positions in the lumbar spine.

Authors:  Jacob Braunstein; John A Hipp; Robert Browning; Trevor F Grieco; Charles A Reitman
Journal:  N Am Spine Soc J       Date:  2020-11-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.