Literature DB >> 18524001

In vivo contact stresses during activities of daily living after knee arthroplasty.

Darryl D D'Lima1, Nikolai Steklov, Benjamin J Fregly, Scott A Banks, Clifford W Colwell.   

Abstract

We implanted an electronic knee prosthesis to measure tibial forces in vivo during activities of daily living after total knee arthroplasty. We used tibial forces and knee kinematic data collected in vivo to calculate contact stresses using finite element analysis. The polyethylene insert was modeled as an elastoplastic material, and predicted contact stresses were validated using pressure sensitive sensors. Peak contact stresses generated during walking were similar but about 18% lower than those calculated for International Standards Organization (ISO)-recommended wear simulation conditions. Stair climbing generated higher contact stresses (32 MPa) than walking (26 MPa). However, both high flexion activities (lunge and kneel) generated even higher contact stresses, with the lunge activity generating the highest stresses (56 MPa). The activities that generated high contact stresses also resulted in high equivalent plastic strain. However, the lunge activity generated dramatically higher plastic equivalent strain than the other activities. In vivo measurement of kinematics, forces, and contact stresses may be used to develop more clinically relevant wear simulator protocols. Contact stresses generated during high flexion activities were substantially higher and were largely due to the reduced contact area in deep flexion rather than due to an increase in contact forces. Our results support the use of "high flexion" designs that improve contact conditions and preserve contact area at high flexion angles.

Entities:  

Mesh:

Year:  2008        PMID: 18524001     DOI: 10.1002/jor.20670

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  17 in total

1.  Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?

Authors:  Sung-Do Cho; Yoon-Seok Youm; Ki-Bong Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-29       Impact factor: 4.342

2.  Gamma Radiation Sterilization Reduces the High-cycle Fatigue Life of Allograft Bone.

Authors:  Anowarul Islam; Katherine Chapin; Emily Moore; Joel Ford; Clare Rimnac; Ozan Akkus
Journal:  Clin Orthop Relat Res       Date:  2015-10-13       Impact factor: 4.176

3.  In vivo kinematics after a cruciate-substituting TKA.

Authors:  Jan Victor; John Kyle P Mueller; Richard D Komistek; Adrija Sharma; Matthew C Nadaud; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2009-09-04       Impact factor: 4.176

4.  The 2011 ABJS Nicolas Andry Award: 'Lab'-in-a-knee: in vivo knee forces, kinematics, and contact analysis.

Authors:  Darryl D D'Lima; Shantanu Patil; Nicolai Steklov; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2011-05-20       Impact factor: 4.176

5.  Analysis of different bicruciate-retaining tibial prosthesis design using a three dimension finite element model.

Authors:  Peiheng He; Xing Li; Shuai Huang; Minghao Liu; Weizhi Chen; Dongliang Xu
Journal:  Am J Transl Res       Date:  2017-05-15       Impact factor: 4.060

6.  Knee contact force in subjects with symmetrical OA grades: differences between OA severities.

Authors:  C Richards; J S Higginson
Journal:  J Biomech       Date:  2010-06-02       Impact factor: 2.712

7.  Results of total knee arthroplasty with NexGen LPS-Flex for osteoarthritis in the valgus knee: a study of 26 patients followed for a minimum of 2 years.

Authors:  Naoki Nakano; Tomoyuki Matsumoto; Hirotsugu Muratsu; Takehiko Matsushita; Koji Takayama; Tokio Matsuzaki; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-17

8.  Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

Authors:  Toshihiro Sera; Yuya Iwai; Takaharu Yamazaki; Tetsuya Tomita; Hideki Yoshikawa; Hisahi Naito; Takeshi Matsumoto; Masao Tanaka
Journal:  J Orthop       Date:  2017-08-09

9.  Parametric analysis of electromechanical and fatigue performance of total knee replacement bearing with embedded piezoelectric transducers.

Authors:  Mohsen Safaei; R Michael Meneghini; Steven R Anton
Journal:  Smart Mater Struct       Date:  2017-08-17       Impact factor: 3.585

10.  Toward the development of virtual surgical tools to aid orthopaedic FE analyses.

Authors:  Srinivas C Tadepalli; Kiran H Shivanna; Vincent A Magnotta; Nicole A Kallemeyn; Nicole M Grosland
Journal:  EURASIP J Adv Signal Process       Date:  2010-01-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.