Literature DB >> 19735886

Image-guided radiotherapy in near real time with intensity-modulated radiotherapy megavoltage treatment beam imaging.

Weihua Mao1, Annie Hsu, Nadeem Riaz, Louis Lee, Rodney Wiersma, Gary Luxton, Christopher King, Lei Xing, Timothy Solberg.   

Abstract

PURPOSE: To utilize image-guided radiotherapy (IGRT) in near real time by obtaining and evaluating the online positions of implanted fiducials from continuous electronic portal imaging device (EPID) imaging of prostate intensity-modulated radiotherapy (IMRT) delivery. METHODS AND MATERIALS: Upon initial setup using two orthogonal images, the three-dimensional (3D) positions of all implanted fiducial markers are obtained, and their expected two-dimensional (2D) locations in the beam's-eye-view (BEV) projection are calculated for each treatment field. During IMRT beam delivery, EPID images of the megavoltage treatment beam are acquired in cine mode and subsequently analyzed to locate 2D locations of fiducials in the BEV. Simultaneously, 3D positions are estimated according to the current EPID image, information from the setup portal images, and images acquired at other gantry angles (the completed treatment fields). The measured 2D and 3D positions of each fiducial are compared with their expected 2D and 3D setup positions, respectively. Any displacements larger than a predefined tolerance may cause the treatment system to suspend the beam delivery and direct the therapists to reposition the patient.
RESULTS: Phantom studies indicate that the accuracy of 2D BEV and 3D tracking are better than 1 mm and 1.4 mm, respectively. A total of 7330 images from prostate treatments were acquired and analyzed, showing a maximum 2D displacement of 6.7 mm and a maximum 3D displacement of 6.9 mm over 34 fractions.
CONCLUSIONS: This EPID-based, real-time IGRT method can be implemented on any external beam machine with portal imaging capabilities without purchasing any additional equipment, and there is no extra dose delivered to the patient.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19735886     DOI: 10.1016/j.ijrobp.2009.04.068

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  13 in total

1.  Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification.

Authors:  H K Looe; Y Uphoff; D Harder; B Poppe; K C Willborn
Journal:  Strahlenther Onkol       Date:  2012-01-12       Impact factor: 3.621

2.  Optimizing fiducial visibility on periodically acquired megavoltage and kilovoltage image pairs during prostate volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Laura Happersett; Bosky Ravindranath; Michael Zelefsky; Gig Mageras; Margie Hunt
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Real-Time 2D MR Cine From Beam Eye's View With Tumor-Volume Projection to Ensure Beam-to-Tumor Conformality for MR-Guided Radiotherapy of Lung Cancer.

Authors:  Xingyu Nie; Guang Li
Journal:  Front Oncol       Date:  2022-06-29       Impact factor: 5.738

4.  Couch and multileaf collimator tracking: A clinical feasibility study for pancreas and liver treatment.

Authors:  Lei Zhang; Thomas LoSasso; Pengpeng Zhang; Margie Hunt; Gig Mageras; Grace Tang
Journal:  Med Phys       Date:  2020-09-11       Impact factor: 4.071

5.  Automatic prostate tracking and motion assessment in volumetric modulated arc therapy with an electronic portal imaging device.

Authors:  Juan Diego Azcona; Ruijiang Li; Edward Mok; Steven Hancock; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-04-19       Impact factor: 7.038

6.  Intrafractional 3D localization using kilovoltage digital tomosynthesis for sliding-window intensity modulated radiation therapy.

Authors:  Pengpeng Zhang; Margie Hunt; Hai Pham; Grace Tang; Gig Mageras
Journal:  Phys Med Biol       Date:  2015-08-25       Impact factor: 3.609

7.  The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking.

Authors:  Stephen Yip; Joerg Rottmann; Ross Berbeco
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

8.  Beam's-eye-view imaging during non-coplanar lung SBRT.

Authors:  Stephen S F Yip; Joerg Rottmann; Ross I Berbeco
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

9.  Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy.

Authors:  Juan Diego Azcona; Ruijiang Li; Edward Mok; Steven Hancock; Lei Xing
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

10.  Design and validation of a MV/kV imaging-based markerless tracking system for assessing real-time lung tumor motion.

Authors:  Pengpeng Zhang; Margie Hunt; Arina B Telles; Hai Pham; Michael Lovelock; Ellen Yorke; Guang Li; Laura Happersett; Andreas Rimner; Gig Mageras
Journal:  Med Phys       Date:  2018-11-13       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.