Literature DB >> 26305232

Intrafractional 3D localization using kilovoltage digital tomosynthesis for sliding-window intensity modulated radiation therapy.

Pengpeng Zhang1, Margie Hunt, Hai Pham, Grace Tang, Gig Mageras.   

Abstract

To implement novel imaging sequences integrated into intensity modulated radiation therapy (IMRT) and determine 3D positions for intrafractional patient motion monitoring and management.In one method, we converted a static gantry IMRT beam into a series of arcs in which dose index and multileaf collimator positions for all control points were unchanged, but gantry angles were modified to oscillate ± 3° around the original angle. Kilovoltage (kV) projections were acquired continuously throughout delivery and reconstructed to provide a series of 6° arc digital tomosynthesis (DTS) images which served to evaluate the in-plane positions of embedded-fiducials/vertebral-body. To obtain out-of-plane positions via triangulation, a 20° gantry rotation with beam hold-off was inserted during delivery to produce a pair of 6° DTS images separated by 14°. In a second method, the gantry remained stationary, but both kV source and detector moved over a 15° longitudinal arc using pitch and translational adjustment of the robotic arms. Evaluation of localization accuracy in an anthropomorphic Rando phantom during simulated intrafractional motion used programmed couch translations from customized scripts. Purpose-built software was used to reconstruct DTS images, register them to reference template images and calculate 3D fiducial positions.No significant dose difference (<0.5%) was found between the original and converted IMRT beams. For a typical hypofractionated spine treatment, 200 single DTS (6° arc) and 10 paired DTS (20° arc) images were acquired for each IMRT beam, providing in-plane and out-of-plane monitoring every 1.6 and 34.5 s, respectively. Mean ± standard deviation error in predicted position was -0.3 ± 0.2 mm, -0.1 ± 0.1 mm in-plane, and 0.2 ± 0.4 mm out-of-plane with rotational gantry, 0.8 ± 0.1 mm, -0.7 ± 0.3 mm in-plane and 1.1 ± 0.1 mm out-of-plane with translational source/detector.Acquiring 3D fiducial positions from kV-DTS during fixed gantry IMRT is technically feasible, and is capable of providing reliable guidance for intrafractional patient motion management.

Entities:  

Mesh:

Year:  2015        PMID: 26305232      PMCID: PMC4976773          DOI: 10.1088/0031-9155/60/17/N335

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Dynamic MLC tracking of moving targets with a single kV imager for 3D conformal and IMRT treatments.

Authors:  Per R Poulsen; Byungchul Cho; Amit Sawant; Dan Ruan; Paul J Keall
Journal:  Acta Oncol       Date:  2010-10       Impact factor: 4.089

2.  First clinical cone-beam CT imaging during volumetric modulated arc therapy.

Authors:  Keiichi Nakagawa; Akihiro Haga; Kenshiro Shiraishi; Hideomi Yamashita; Hiroshi Igaki; Atsuro Terahara; Kuni Ohtomo; Shigeki Saegusa; Takashi Shiraki; Takashi Oritate; Kiyoshi Yoda
Journal:  Radiother Oncol       Date:  2008-12-04       Impact factor: 6.280

3.  Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT.

Authors:  Sabbir Hossain; Ping Xia; Cynthia Chuang; Lynn Verhey; Alexander R Gottschalk; Guanwei Mu; Lijun Ma
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

4.  A novel method for megavoltage scatter correction in cone-beam CT acquired concurrent with rotational irradiation.

Authors:  Marcel van Herk; Lennert Ploeger; Jan-Jakob Sonke
Journal:  Radiother Oncol       Date:  2011-09-15       Impact factor: 6.280

5.  Real-time automatic fiducial marker tracking in low contrast cine-MV images.

Authors:  Wei-Yang Lin; Shu-Fang Lin; Sheng-Chang Yang; Shu-Cheng Liou; Ravinder Nath; Wu Liu
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT.

Authors:  J A Ng; J T Booth; R T O'Brien; E Colvill; C-Y Huang; P R Poulsen; P J Keall
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

7.  Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-02-03       Impact factor: 7.038

8.  Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy.

Authors:  Juan Diego Azcona; Ruijiang Li; Edward Mok; Steven Hancock; Lei Xing
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

9.  Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy.

Authors:  Pengpeng Zhang; Margie Hunt; Laura Happersett; Brett Cox; Gig Mageras
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

10.  Determining leaf trajectories for dynamic multileaf collimators with consideration of marker visibility: an algorithm study.

Authors:  Bo Zhao; Jianrong Dai
Journal:  J Radiat Res       Date:  2014-06-08       Impact factor: 2.724

View more
  2 in total

1.  Optimizing fiducial visibility on periodically acquired megavoltage and kilovoltage image pairs during prostate volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Laura Happersett; Bosky Ravindranath; Michael Zelefsky; Gig Mageras; Margie Hunt
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

2.  Clinical Study of Orthogonal-View Phase-Matched Digital Tomosynthesis for Lung Tumor Localization.

Authors:  You Zhang; Lei Ren; Irina Vergalasova; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2017-04-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.