Literature DB >> 23608236

Automatic prostate tracking and motion assessment in volumetric modulated arc therapy with an electronic portal imaging device.

Juan Diego Azcona1, Ruijiang Li, Edward Mok, Steven Hancock, Lei Xing.   

Abstract

PURPOSE: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). METHODS AND MATERIALS: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement.
RESULTS: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm.
CONCLUSION: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23608236      PMCID: PMC3686883          DOI: 10.1016/j.ijrobp.2013.03.007

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  20 in total

1.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction.

Authors:  Aart J Nederveen; Uulke A van der Heide; Homan Dehnad; R Jeroen A van Moorselaar; Pieter Hofman; Jan J W Lagendijk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-05-01       Impact factor: 7.038

2.  Optimized hybrid megavoltage-kilovoltage imaging protocol for volumetric prostate arc therapy.

Authors:  Wu Liu; Rodney D Wiersma; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-05-14       Impact factor: 7.038

3.  Day-to-day reproducibility of prostate intrafraction motion assessed by multiple kV and MV imaging of implanted markers during treatment.

Authors:  Theodore F Mutanga; Hans C J de Boer; Vinayakrishnan Rajan; Maarten L P Dirkx; Luca Incrocci; Ben J M Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-10-20       Impact factor: 7.038

4.  Image-guided radiotherapy in near real time with intensity-modulated radiotherapy megavoltage treatment beam imaging.

Authors:  Weihua Mao; Annie Hsu; Nadeem Riaz; Louis Lee; Rodney Wiersma; Gary Luxton; Christopher King; Lei Xing; Timothy Solberg
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-10-01       Impact factor: 7.038

5.  Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

Authors:  Yunzhi Ma; Louis Lee; O Keshet; Paul Keall; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

6.  A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery.

Authors:  Ruijiang Li; Benjamin P Fahimian; Lei Xing
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  Prostate intrafraction motion assessed by simultaneous kilovoltage fluoroscopy at megavoltage delivery I: clinical observations and pattern analysis.

Authors:  Justus Adamson; Qiuwen Wu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-25       Impact factor: 7.038

8.  Kilovoltage intrafraction monitoring for prostate intensity modulated arc therapy: first clinical results.

Authors:  Jin Aun Ng; Jeremy T Booth; Per R Poulsen; Walther Fledelius; Esben Schjødt Worm; Thomas Eade; Fiona Hegi; Andrew Kneebone; Zdenka Kuncic; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-09-11       Impact factor: 7.038

9.  Intrafraction prostate motion during IMRT for prostate cancer.

Authors:  Eugene Huang; Lei Dong; Anurag Chandra; Deborah A Kuban; Isaac I Rosen; Anissa Evans; Alan Pollack
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

10.  Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy.

Authors:  Juan Diego Azcona; Ruijiang Li; Edward Mok; Steven Hancock; Lei Xing
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

View more
  8 in total

Review 1.  Review of Real-Time 3-Dimensional Image Guided Radiation Therapy on Standard-Equipped Cancer Radiation Therapy Systems: Are We at the Tipping Point for the Era of Real-Time Radiation Therapy?

Authors:  Paul J Keall; Doan Trang Nguyen; Ricky O'Brien; Pengpeng Zhang; Laura Happersett; Jenny Bertholet; Per R Poulsen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-04-14       Impact factor: 7.038

2.  A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

Authors:  Y Chi; N H Rezaeian; C Shen; Y Zhou; W Lu; M Yang; R Hannan; X Jia
Journal:  Phys Med Biol       Date:  2017-07-07       Impact factor: 3.609

3.  Time and frequency to observe fiducial markers in MLC-modulated fields during prostate IMRT/VMAT beam delivery.

Authors:  Qianqian Xu; Xu Tong; Muhan Lin; Xiaoming Chen; Ahmed ElDib; Teh Lin; Lili Chen; C-M Charlie Ma
Journal:  Phys Med       Date:  2020-07-14       Impact factor: 2.685

4.  A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy.

Authors:  Malcolm D Mattes; Jennifer C Lee; Sara Elnaiem; Adel Guirguis; N C Ikoro; Hani Ashamalla
Journal:  Radiat Oncol J       Date:  2014-03-27

5.  Development and clinical evaluation of a simple optical method to detect and measure patient external motion.

Authors:  Benigno Barbés; Juan Diego Azcona; Elena Prieto; José Manuel de Foronda; Marina García; Javier Burguete
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

6.  An open-source software for monitoring intrafraction motion during external beam radiation therapy based on superimposition of contours of projected ROIs on cine-MV images.

Authors:  Rémi Lessard; Nicolas M Tremblay; Marc-Émile Plourde; Mathieu Guillot
Journal:  J Appl Clin Med Phys       Date:  2020-06-07       Impact factor: 2.102

7.  Dosimetric benefits of daily treatment plan adaptation for prostate cancer stereotactic body radiotherapy.

Authors:  Miriam Eckl; Gustavo R Sarria; Sandra Springer; Marvin Willam; Arne M Ruder; Volker Steil; Michael Ehmann; Frederik Wenz; Jens Fleckenstein
Journal:  Radiat Oncol       Date:  2021-08-04       Impact factor: 3.481

8.  Studies of Intra-Fraction Prostate Motion During Stereotactic Irradiation in First Irradiation and Re-Irradiation.

Authors:  Alexandre Taillez; Andre-Michel Bimbai; Thomas Lacornerie; Marie-Cecile Le Deley; Eric F Lartigau; David Pasquier
Journal:  Front Oncol       Date:  2021-07-14       Impact factor: 6.244

  8 in total