Literature DB >> 19727668

[Five-year survival rate of the Allofit titanium press-fit cup].

K Schroeder1, A Moehlenbruch, M Zimmermann-Stenzel, D Parsch.   

Abstract

BACKGROUND: The Allofit titanium press-fit cup has become the best-selling cementless acetabular implant in Germany, with approximately 30,000 implants sold in 2007. However, only a limited number of scientific publications - mostly from the development centres in Austria - support this success on the market.
METHODS: At our institution in 1999-2000, 174 total hip replacements were performed using the Allofit cementless press-fit cup. At a mean follow-up of 5.3 years (range 40-85 months), 154 patients were evaluated clinically and radiographically, representing a follow-up rate of 89%.
RESULTS: The 5-year survival rate was 98.1% (95% CI: 95.8-100%), with revision for any reason as an end point. Three cups were revised (aseptic loosening with one, and two septic complications). The average Harris hip score was 89.1+/-13.7 in all unrevised patients.
CONCLUSION: We confirm the excellent survival rates of the Allofit cup as reported by the development centres, supporting the ongoing use of the cup at our institution.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19727668     DOI: 10.1007/s00132-009-1466-y

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  24 in total

Review 1.  Current status of acetabular fixation in primary total hip arthroplasty.

Authors:  E W Morscher
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

2.  Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.

Authors:  Olav Reikerås; Ragnhild B Gunderson
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-24       Impact factor: 3.067

3.  Middle-term results of threaded acetabular cups. High failure rates five years after surgery.

Authors:  H G Simank; D R Brocai; D Reiser; M Thomsen; D Sabo; M Lukoschek
Journal:  J Bone Joint Surg Br       Date:  1997-05

4.  The transgluteal approach to the hip joint.

Authors:  R Bauer; F Kerschbaumer; S Poisel; W Oberthaler
Journal:  Arch Orthop Trauma Surg       Date:  1979-10

5.  Failure of the Mecron screw-in ring.

Authors:  W N Capello; R A Colyer; C B Kernek; J V Carnahan; J J Hess
Journal:  J Bone Joint Surg Br       Date:  1993-09

6.  The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty.

Authors:  U Müller; E Gautier; C Roeder; A Busato
Journal:  J Bone Joint Surg Br       Date:  2003-01

7.  Long-term fate of uncemented, threaded acetabular components with smooth surface treatment: minimum 10-year follow-up of two different designs.

Authors:  Peter R Aldinger; Marc Thomsen; Martin Lukoschek; Hans Mau; Volker Ewerbeck; Steffen J Breusch
Journal:  Arch Orthop Trauma Surg       Date:  2004-07-07       Impact factor: 3.067

8.  Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up.

Authors:  Pacharapol Udomkiat; Lawrence D Dorr; Zhinian Wan
Journal:  J Bone Joint Surg Am       Date:  2002-07       Impact factor: 5.284

9.  Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study.

Authors:  Douglas Naudie; Christopher P Roeder; Javad Parvizi; Daniel J Berry; Stefan Eggli; Andre Busato
Journal:  J Arthroplasty       Date:  2004-10       Impact factor: 4.757

10.  Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty.

Authors:  Alejandro González Della Valle; Adriana Zoppi; Margaret G E Peterson; Eduardo A Salvati
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

View more
  2 in total

1.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

2.  10-year results of the uncemented Allofit press-fit cup in young patients.

Authors:  Marcus R Streit; Stefan Weiss; Franziska Andreas; Thomas Bruckner; Tilman Walker; J Philippe Kretzer; Volker Ewerbeck; Christian Merle
Journal:  Acta Orthop       Date:  2014-05-30       Impact factor: 3.717

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.