Literature DB >> 1729002

Current status of acetabular fixation in primary total hip arthroplasty.

E W Morscher1.   

Abstract

Factors that influence the outcome of acetabular replacement are design materials, means of fixation, operative technique, and patient-related parameters (e.g., etiology of osteoarthrosis). Whereas improved cementing techniques have produced a marked reduction in the rate of femoral component loosening, the incidence of acetabular loosening has been only slightly influenced by such improvements. Presently, uncemented porous-coated acetabular components represent the state of the art in total hip arthroplasty. Experimental and clinical data have shown in histologic, radiologic, clinical, and survivorship studies that hemispheric cups are superior to other designs and that primary stability can be better maintained by creating "intrinsic" stability (e.g., "oversized cup") rather than by screw fixation. Threaded cups have failed to demonstrate any improvement in results and have been virtually abandoned in the United States. The idea of metal backing has some obvious theoretical advantages. However, metal backing has failed to provide any improvement with respect to cemented cups. There are great reservations concerning metal backing in cementless fixation. Although there is some enthusiasm about hydroxyapatite, a "wait-and-see" attitude is justified because of the brittleness of the material, its questionable strength of bonding to substrate, and its unproven long-term behavior in vivo. Polyethylene as a bearing surface remains problematic, and the future will show whether new technologies are able to solve the problems encountered with metal-to-metal combinations. For the size of the femoral head, a compromise between smaller (22 mm) and larger (32 mm) components seems to be most effective.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1729002

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

Review 1.  Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty.

Authors:  K-H Widmer
Journal:  Int Orthop       Date:  2007-08       Impact factor: 3.075

2.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

3.  [Five-year survival rate of the Allofit titanium press-fit cup].

Authors:  K Schroeder; A Moehlenbruch; M Zimmermann-Stenzel; D Parsch
Journal:  Orthopade       Date:  2010-01       Impact factor: 1.087

4.  Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.

Authors:  Guido Garavaglia; Anne Lübbeke; Christophe Barea; Constantinos Roussos; Robin Peter; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2010-06-04       Impact factor: 3.075

5.  Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup.

Authors:  Martin Kaipel; Anton Prenner; Sebastian Bachl; Sebastian Farr; Günter Sinz
Journal:  Wien Klin Wochenschr       Date:  2014-01-18       Impact factor: 1.704

6.  Total hip replacement with solid autologous femoral head graft for hip dysplasia.

Authors:  B Hintermann; E W Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

7.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

8.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

9.  Survivorship of monoblock trabecular metal cups in primary THA : midterm results.

Authors:  Konstantinos N Malizos; Konstantinos Bargiotas; Loukia Papatheodorou; Michael Hantes; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

10.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.