Literature DB >> 14630848

Serum cobalt levels after metal-on-metal total hip arthroplasty.

Wolfram Brodner1, Peter Bitzan, Vanee Meisinger, Alexandra Kaider, Florian Gottsauner-Wolf, Rainer Kotz.   

Abstract

BACKGROUND: Systemic cobalt dissemination from the Metasul Co-28Cr-6Mo-0.2C metal-on-metal total hip prosthesis has been demonstrated in the first year after implantation. The aim of this prospective study was to monitor the serum cobalt concentrations in patients during the first five years after total hip arthroplasty with a metal-on-metal articulation.
METHODS: A total hip arthroplasty was performed without cement in 100 consecutive patients who had either unilateral osteoarthritis or unilateral osteonecrosis. Fifty patients were randomized to be treated with a metal-on-metal articulation, and fifty patients, with a ceramic-on-polyethylene bearing. The femoral stem was made of a Ti-6Al-7Nb alloy, and the threaded acetabular cup was made of commercially pure titanium. Blood samples were taken before the operation and at multiple time-points for five years after the operation. Serum cobalt concentrations were measured with use of atomic absorption spectrometry.
RESULTS: In the metal-on-metal group, the median serum cobalt concentration was 1 micro g/L at one year after surgery and 0.7 micro g/L at five years. The median of the serum cobalt concentrations measured from three to twelve months did not differ from the median of subsequent measurements, with the numbers available. The median serum cobalt level in the control group of patients treated with the ceramic-on-polyethylene articulation was below the detection limit at all time-points.
CONCLUSIONS: Systemic cobalt release from Metasul metal-on-metal articulations was demonstrated throughout the five-year study period. The median serum cobalt concentrations were found to be slightly above the detection limit and remained in a constant range. The serum cobalt concentrations did not reflect a so-called run-in wear period of the metal-on-metal articulations.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14630848     DOI: 10.2106/00004623-200311000-00017

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  42 in total

1.  Bone mineral density of the proximal femur recovers after metal-on-metal hip resurfacing.

Authors:  Matteo Cadossi; Antonio Moroni; Matteo Romagnoli; Eugenio Chiarello; Cesare Faldini; Sandro Giannini
Journal:  Clin Cases Miner Bone Metab       Date:  2010-05

2.  Serum ion level after metal-on-metal THA in patients with renal failure.

Authors:  Chang Ich Hur; Taek Rim Yoon; Sang Gwon Cho; Eun Kyoo Song; Jong Keun Seon
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  Clinical and biological assessment of cemented titanium femoral stems: an 11-year experience.

Authors:  Patrick Boyer; Jean-Yves Lazennec; Joel Poupon; Marc-Antoine Rousseau; Philippe Ravaud; Yves Catonné
Journal:  Int Orthop       Date:  2008-10-28       Impact factor: 3.075

Review 4.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

5.  'Pseudotumour' invading the proximal femur with normal metal ions following metal on metal hip resurfacing.

Authors:  Harry Krishnan; Kapil Sugand; Ibrahim Ali; Jay Smith
Journal:  BMJ Case Rep       Date:  2015-02-10

6.  CORR Insights®: can wear explain the histological variation around metal-on-metal total hips?

Authors:  McKinley C Lawson
Journal:  Clin Orthop Relat Res       Date:  2014-09-23       Impact factor: 4.176

7.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

8.  Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Keri L Satterwhite
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

9.  Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-02-01

10.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.