Optimal "image-based" weighting for energy-resolved CT.

Taly Gilat Schmidt1.   

Abstract

This paper investigates a method of reconstructing images from energy-resolved CT data with negligible beam-hardening artifacts and improved contrast-to-nosie ratio (CNR) compared to conventional energy-weighting methods. Conceptually, the investigated method first reconstructs separate images from each energy bin. The final image is a linear combination of the energy-bin images, with the weights chosen to maximize the CNR in the final image. The optimal weight of a particular energy-bin image is derived to be proportional to the contrast-to-noise-variance ratio in that image. The investigated weighting method is referred to as "image-based" weighting, although, as will be described, the weights can be calculated and the energy-bin data combined prior to reconstruction. The performance of optimal image-based energy weighting with respect to CNR and beam-hardening artifacts was investigated through simulations and compared to that of energy integrating, photon counting, and previously studied optimal "projection-based" energy weighting. Two acquisitions were simulated: dedicated breast CT and a conventional thorax scan. The energy-resolving detector was simulated with five energy bins. Four methods of estimating the optimal weights were investigated, including task-specific and task-independent methods and methods that require a single reconstruction versus multiple reconstructions. Results demonstrated that optimal image-based weighting improved the CNR compared to energy-integrating weighting by factors of 1.15-1.6 depending on the task. Compared to photon-counting weighting, the CNR improvement ranged from 1.0 to 1.3. The CNR improvement factors were comparable to those of projection-based optimal energy weighting. The beam-hardening cupping artifact increased from 5.2% for energy-integrating weighting to 12.8% for optimal projection-based weighting, while optimal image-based weighting reduced the cupping to 0.6%. Overall, optimal image-based energy weighting provides images with negligible beam-hardening artifacts and improved CNR compared to energy-integrating and photon-counting methods.

Mesh:

Year:  2009        PMID: 19673201     DOI: 10.1118/1.3148535

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  44 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  Spectral response model for a multibin photon-counting spectral computed tomography detector and its applications.

Authors:  Xuejin Liu; Mats Persson; Hans Bornefalk; Staffan Karlsson; Cheng Xu; Mats Danielsson; Ben Huber
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-11

3.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT.

Authors:  Jiulong Liu; Huanjun Ding; Sabee Molloi; Xiaoqun Zhang; Hao Gao
Journal:  IEEE Trans Med Imaging       Date:  2016-07-07       Impact factor: 10.048

4.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

Review 5.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

6.  Near optimal energy selective x-ray imaging system performance with simple detectors.

Authors:  Robert E Alvarez
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

7.  The effects of extending the spectral information acquired by a photon-counting detector for spectral CT.

Authors:  Taly Gilat Schmidt; Kevin C Zimmerman; Emil Y Sidky
Journal:  Phys Med Biol       Date:  2015-01-23       Impact factor: 3.609

8.  Energy weighting improves dose efficiency in clinical practice: implementation on a spectral photon-counting mammography system.

Authors:  Johan Berglund; Henrik Johansson; Mats Lundqvist; Björn Cederström; Erik Fredenberg
Journal:  J Med Imaging (Bellingham)       Date:  2014-08-28

9.  Photon counting performance of amorphous selenium and its dependence on detector structure.

Authors:  Jann Stavro; Amir H Goldan; Wei Zhao
Journal:  J Med Imaging (Bellingham)       Date:  2018-10-30

Review 10.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Authors:  Shuai Leng; Michael Bruesewitz; Shengzhen Tao; Kishore Rajendran; Ahmed F Halaweish; Norbert G Campeau; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiographics       Date:  2019 May-Jun       Impact factor: 5.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.