Literature DB >> 19636548

The use of flat panel angioCT (DynaCT) for navigation through a deformed and fractured carotid stent.

Pasquale Mordasini1, Fahmi Al-Senani, Jan Gralla, Dai-Do Do, Caspar Brekenfeld, Gerhard Schroth.   

Abstract

Navigation through a previously deployed and deformed stent is a difficult interventional task. Inadvertent navigation through the struts of a stent can potentially lead to incomplete secondary stent extension and vessel occlusion. Better visualisation of the pathway through the stent can reduce the risks of the procedural complications and reduce the reluctance of the interventionalist to navigate through a previously deployed stent. We describe a technique of visualisation of the pathway navigated by a guidewire through a previously deployed deformed and fractured carotid stent by the use of DynaCT. Three-dimensional reconstruction of the stent/microwire allows excellent visualisation of the correct pathway of the microwire within the stent.

Mesh:

Year:  2009        PMID: 19636548     DOI: 10.1007/s00234-009-0556-1

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  13 in total

1.  Acute fracture of ACCULINK carotid stent during post dilation.

Authors:  Najibullah Habib; Jan van der Heyden
Journal:  Catheter Cardiovasc Interv       Date:  2009-12-01       Impact factor: 2.692

2.  Fracture of a carotid stent: a word of caution.

Authors:  Nicolas Diehm; Samuel Baum; Barry T Katzen; Margaret Kovacs; James Benenati
Journal:  J Vasc Interv Radiol       Date:  2008-04       Impact factor: 3.464

3.  Prevalence and clinical impact of stent fractures after femoropopliteal stenting.

Authors:  Dierk Scheinert; Susanne Scheinert; Jacqueline Sax; Christopher Piorkowski; Sven Bräunlich; Matthias Ulrich; Giancarlo Biamino; Andrej Schmidt
Journal:  J Am Coll Cardiol       Date:  2005-01-18       Impact factor: 24.094

4.  Stent fracture after endoluminal repair of a carotid artery pseudoaneurysm.

Authors:  Jean-Paul P M de Vries; Rob W Meijer; Jos C van den Berg; Joost M R Meijer; Eric D W M van de Pavoordt
Journal:  J Endovasc Ther       Date:  2005-10       Impact factor: 3.487

5.  Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: value of angiographic computed tomography: technical case report.

Authors:  Goetz Benndorf; Benjamin Claus; Charles M Strother; Lee Chang; Richard P Klucznik
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

6.  Fracture of a carotid stent: an unexpected complication.

Authors:  Arif Rahim Valibhoy; Bibombe Patrice Mwipatayi; Kishore Sieunarine
Journal:  J Vasc Surg       Date:  2007-03       Impact factor: 4.268

7.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

8.  3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.

Authors:  L-D Jou; A Mohamed; D H Lee; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

9.  AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data.

Authors:  Philip M White; John N Gilmour; Nicholas W Weir; Brian Innes; Robin J Sellar
Journal:  Neuroradiology       Date:  2007-12-21       Impact factor: 2.804

10.  Stenting for carotid artery stenosis: fractures, proposed etiology and the need for surveillance.

Authors:  Adrian James Ling; Patrice Mwipatayi; Tarun Gandhi; Kishore Sieunarine
Journal:  J Vasc Surg       Date:  2008-04-28       Impact factor: 4.268

View more
  7 in total

1.  Artifact reduction of different metallic implants in flat detector C-arm CT.

Authors:  S-C Hung; C-C Wu; C-J Lin; W-Y Guo; C-B Luo; F-C Chang; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2014-01-23       Impact factor: 3.825

2.  Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery.

Authors:  Seisaku Kanayama; Takayuki Hara; Yusuke Hamada; Yuji Matsumaru
Journal:  Neuroradiology       Date:  2014-11-05       Impact factor: 2.804

3.  Applicability of tableside flat panel detector CT parenchymal cerebral blood volume measurement in neurovascular interventions: preliminary clinical experience.

Authors:  P Mordasini; M El-Koussy; C Brekenfeld; G Schroth; U Fischer; J Beck; J Gralla
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-29       Impact factor: 3.825

4.  Intravenous flat-detector CT angiography in acute ischemic stroke management.

Authors:  Raphaël Blanc; Silvia Pistocchi; Drazenko Babic; Bruno Bartolini; Michaël Obadia; Sonia Alamowitch; Michel Piotin
Journal:  Neuroradiology       Date:  2011-05-31       Impact factor: 2.804

5.  Percutaneous balloon compression technique using intraoperative contrasted DynaCT for the treatment of refractory trigeminal neuralgia: initial experience.

Authors:  Aakangsha Jain; Bilal Ibrahim; Assad Ali; Baha'eddin A Muhsen; Edinson Najera; Badih Adada; Hamid Borghei-Razavi; Michal Obrzut
Journal:  Neurosurg Rev       Date:  2021-10-02       Impact factor: 3.042

6.  In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T.

Authors:  Michael Lettau; Annett Sauer; Sabine Heiland; Stefan Rohde; Julia Reinhardt; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2009-11-19       Impact factor: 2.804

Review 7.  Toward the era of a one-stop imaging service using an angiography suite for neurovascular disorders.

Authors:  Sheng-Che Hung; Chung-Jung Lin; Wan-Yuo Guo; Feng-Chi Chang; Chao-Bao Luo; Michael Mu-Huo Teng; Cheng-Yen Chang
Journal:  Biomed Res Int       Date:  2013-05-14       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.