Literature DB >> 19631130

Optical quality of foldable monofocal intraocular lenses before and after injection: comparative evaluation using a double-pass system.

Meritxell Vilaseca1, Montserrat Arjona, Jaume Pujol, Luis Issolio, José L Güell.   

Abstract

PURPOSE: To use the double-pass technique to evaluate the in vitro optical quality of foldable monofocal intraocular lenses (IOLs) used to correct aphakia.
SETTING: Universitat Politècnica de Catalunya, Terrassa, and Instituto de Microcirugía Ocular de Barcelona, Barcelona, Spain; Universidad Nacional de Tucumán, Tucumán, Argentina.
METHODS: This study assessed the in vitro optical quality of 7 IOLs before and after injection in an artificial eye that was attached to a double-pass system (Optical Quality Analysis System [OQAS]). The procedure imitated the conventional in vivo technique used to assess the optical quality of eyes with an IOL. The following parameters were evaluated: point-spread function, modulation transfer function (MTF), MTF cutoff frequency, Strehl ratio, and OQAS values.
RESULTS: The in vitro optical quality of most IOLs was as good after injection as before injection. In 1 IOL, the post-injection optical quality was statistically significantly different but the optical quality remained high.
CONCLUSIONS: Results indicate that after an IOL is placed in the eye, its optical performance will be good, providing good visual quality. The eye cell model attached to the double-pass system was useful and effective for fully characterizing the optical quality of IOLs and evaluating variations resulting from the injection process.

Entities:  

Mesh:

Year:  2009        PMID: 19631130     DOI: 10.1016/j.jcrs.2009.03.022

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.

Authors:  Ai-Lian Hu; Li-Ya Qiao; Ye Zhang; Xiao-Gu Cai; Lei Li; Xiu-Hua Wan
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Optical quality of toric intraocular lens implantation in cataract surgery.

Authors:  Xian-Wen Xiao; Jing Hao; Hong Zhang; Fang Tian
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

3.  Evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes.

Authors:  Hun Lee; Kwanghyun Lee; Ji Min Ahn; Eung Kweon Kim; Bradford Sgrignoli; Tae-im Kim
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

4.  Repeatability and reproducibility of a double-pass optical quality analysis device.

Authors:  Chen-Chen Xu; Ting Xue; Qin-Mei Wang; Yi-Ni Zhou; Jin-Hai Huang; A-Yong Yu
Journal:  PLoS One       Date:  2015-02-03       Impact factor: 3.240

5.  Assessment of Optical Quality at Different Contrast Levels in Pseudophakic Eyes.

Authors:  Chang Won Park; Hyojin Kim; Choun-Ki Joo
Journal:  J Ophthalmol       Date:  2016-01-28       Impact factor: 1.909

6.  Extent of multifocality with corneal manipulation in manual small incision cataract surgery with monofocal posterior chamber intraocular lens implantation.

Authors:  Parasappa Bandrakalli; Vidya Rani; R B Yogesh; Nirmal Kumar Bagrecha; G Pavan
Journal:  Indian J Ophthalmol       Date:  2021-02       Impact factor: 1.848

7.  Strehl Ratio and Myopia in Chinese Adolescents: The Tuyou County Pediatric Eye (TYPE) Study.

Authors:  Xiaoyan Bian; Yuxia Guo; Shixuan Guo; Song Zhang; Guisen Zhang; Lei Liu; Yajun Yang; Jun Liu
Journal:  Int J Gen Med       Date:  2021-04-27

8.  Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses.

Authors:  Lingying Ye; Tianyu Chen; Zhixiang Hu; Qingwen Yang; Qiudong Su; Jin Li
Journal:  Ann Transl Med       Date:  2021-01

9.  Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00).

Authors:  Young Joon Jeon; Yisang Yoon; Tae-Im Kim; Kyungmin Koh
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2021-10-01
  9 in total