| Literature DB >> 33569446 |
Lingying Ye1, Tianyu Chen2, Zhixiang Hu2, Qingwen Yang1, Qiudong Su1, Jin Li1.
Abstract
BACKGROUND: To compare the visual performance of MF30 asymmetric refractive multifocal intraocular lenses (MIOLs) with ZMB00 all optic zone diffractive MIOLs.Entities:
Keywords: Asymmetric; diffractive; multifocal intraocular lens; refractive; visual quality
Year: 2021 PMID: 33569446 PMCID: PMC7867926 DOI: 10.21037/atm-20-7777
Source DB: PubMed Journal: Ann Transl Med ISSN: 2305-5839
Figure 1Two types of multifocal IOLs. (A) Lentis Mplus LS-313 MF30 multifocal IOL; (B) ZMB00 multifocal IOL. IOL, intraocular lens.
Figure 2Ray tracing diagrams show the focal depth of each MIOL. (A) Lentis Mplus LS-313 MF30 multifocal IOL; (B) ZMB00 multifocal IOL. MIOL, multifocal intraocular lens; IOL, intraocular lens.
Clinical and demographic data of patients implanted with refractive and diffractive MIOLs (VA results were recorded in logMAR)
| Basic information | Refractive MIOL | Diffractive MIOL | P value |
|---|---|---|---|
| Age | 69.48±8.09 | 68.41±8.77 | 0.331 |
| Gender (male/female) | 20/15 | 18/17 | 0.189 |
| Preoperative VA | 0.51±0.22 | 0.51±0.21 | 0.478 |
Data are expressed as the mean ± standard deviation (SD) or median (range). Differences between the groups were analyzed by independent t test for normally distributed data and the Mann-Whitney U test for non-normally distributed data. Categorical data was compared using the Chi-squared (χ2) test. MIOL, multifocal intraocular lens; logMAR, logarithm of the minimum angle of resolution; VA, visual acuity.
Postoperative visual and refractive outcomes in the refractive and diffractive groups at 3 months postoperatively (results were recorded in logMAR)
| Measure | Refractive MIOL | Diffractive MIOL | P value |
|---|---|---|---|
| Distance | |||
| Uncorrected | 0.06±0.07 | 0.09±0.09 | 0.236 |
| Best-corrected | 0.05±0.06 | 0.03±0.05 | 0.337 |
| Intermediate | |||
| Uncorrected | 0.24±0.10 | 0.31±0.13 | 0.029* |
| Distance-corrected | 0.22±0.09 | 0.31±0.14 | 0.016* |
| Near | |||
| Uncorrected | 0.23±0.12 | 0.24±0.14 | 0.800 |
| Distance-corrected | 0.21±0.11 | 0.20±0.12 | 0.866 |
Data are expressed as the mean ± SD or median (range). Differences between the groups were analyzed by independent t test for normally distributed data and the Mann-Whitney U test for non-normally distributed data. *, statistically significant difference between the groups (P value <0.05). logMAR, logarithm of the minimum angle of resolution; MIOL, multifocal intraocular lens.
Objective measures by OQAS II in the refractive and diffractive groups at 3 months postoperatively (the pupil is 4 mm)
| OQAS items | Refractive MIOL | Diffractive MIOL | P value |
|---|---|---|---|
| MTF cut-off (cpd) | 22.74±12.29 | 30.50±10.04 | 0.014* |
| OSI | 2.52±1.28 | 2.16±0.98 | 0.294 |
| Strehl ratio | 0.14±0.08 | 0.17±0.06 | 0.104 |
| OV100% | 0.75±0.41 | 1.02±0.34 | 0.011* |
| OV20% | 0.52±0.34 | 0.71±0.25 | 0.030* |
| OV9% | 0.33±0.23 | 0.42±0.15 | 0.100 |
Data are expressed as the mean ± SD or median (range). Differences between the groups were analyzed by independent t test for normally distributed data and the Mann-Whitney U test for non-normally distributed data. *, statistically significant difference between the groups (P value <0.05). OQAS, optical quality analysis system; MTF, modulation transfer function; MIOL, multifocal intraocular lens; OSI, objective scatter index; SR, Strehl ratio; OV, OQAS value.
Figure 3Defocusing curves of refractive and diffractive groups.
Questionnaire results in the refractive and diffractive groups at 3 months postoperatively
| Subjective visual quality | Refractive MIOL | Diffractive MIOL | P value |
|---|---|---|---|
| Glare/halo | 10/35 | 8/35 | 0.784 |
| Independence spectacles ratio | 21/35 | 27/35 | 0.240 |
| Overall satisfaction (score ≥9) | 20/35 | 21/35 | 0.971 |
Data are expressed as the mean ± SD or median (range). Difference between groups were analyzed by χ2 test and Spearman rank correlation. MIOL, multifocal intraocular lens.