Literature DB >> 19629481

Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Michael Clarius1, Alexander W Jung, Marcus R Streit, Christian Merle, Patric Raiss, Peter R Aldinger.   

Abstract

In the 1970s, high failure rates of cemented acetabular components, especially in young patients, in the middle- and long-term prompted a search for alternatives. The Mecring was one of the most popular first generation uncemented, threaded cups widely used in the 1980s for arthroplasty of the hip. First generation threaded cups commonly had smooth surface treatment and showed unacceptably high failure rates in the mid-term. In a consecutive series of 209 patients, 221 threaded uncemented acetabular cups with smooth surface treatment (Mecring) had been implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. The mean time of follow-up was 17 (range 15-20) years. In 91 (41%) hips the acetabular component had been revised or was awaiting revision: two hips for infection and 84 (38%) for aseptic loosening. Five hips were awaiting revision. The survival rate for all revisions including hips awaiting revision was 49% (95% CI: 41-57%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. Patients with these components must be closely monitored as the failure rate remains high in the long-term.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19629481      PMCID: PMC2989098          DOI: 10.1007/s00264-009-0843-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  32 in total

1.  Stress analysis of threaded cups.

Authors:  H Effenberger; U Witzel; F Lintner; W Rieger
Journal:  Int Orthop       Date:  2001       Impact factor: 3.075

2.  Functional results of hip arthroplasty with acrylic prosthesis.

Authors:  R M D'AUBIGNE; M POSTEL
Journal:  J Bone Joint Surg Am       Date:  1954-06       Impact factor: 5.284

3.  Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years.

Authors:  M Pospischill; K Knahr
Journal:  J Bone Joint Surg Br       Date:  2005-09

4.  Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.

Authors:  Olav Reikerås; Ragnhild B Gunderson
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-24       Impact factor: 3.067

5.  Survival of the cementless Spotorno stem in the second decade.

Authors:  Peter R Aldinger; Alexander W Jung; Steffen J Breusch; Volker Ewerbeck; Dominik Parsch
Journal:  Clin Orthop Relat Res       Date:  2009-06-06       Impact factor: 4.176

6.  Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.

Authors:  Alexander Grübl; Catharina Chiari; Martin Gruber; Alexandra Kaider; Florian Gottsauner-Wolf
Journal:  J Bone Joint Surg Am       Date:  2002-03       Impact factor: 5.284

7.  Minimum ten-year follow-up clinical and radiographic results of Mark I and Mark II Lord type femoral component in total hip arthroplasty.

Authors:  S Inoue; T Kubo; T Maeda; K Hirakawa; T Koshino; Y Wu; K Ueshima; T Ogura; Y Hirasawa
Journal:  J Orthop Sci       Date:  2001       Impact factor: 1.601

8.  Cementless Lord total hip arthroplasty: cup loosening common after minimum 10-year follow-up of 103 hips.

Authors:  T Kubo; S Inoue; T Maeda; Y Arai; K Hirakawa; Y Wu; H Suehara; T Ogura; Y Hirasawa
Journal:  Acta Orthop Scand       Date:  2001-12

9.  Cementless hip arthroplasty in the treatment of patients with femoral head necrosis.

Authors:  T A Xenakis; J Gelalis; T A Koukoubis; K C Zaharis; P N Soucacos
Journal:  Clin Orthop Relat Res       Date:  2001-05       Impact factor: 4.176

10.  Survival analysis of cementless grit-blasted titanium total hip arthroplasties.

Authors:  C Delaunay; A I Kapandji
Journal:  J Bone Joint Surg Br       Date:  2001-04
View more
  6 in total

1.  Long-term results of cementless femoral reconstruction following intertrochanteric osteotomy.

Authors:  Christian Merle; Marcus R Streit; Moritz Innmann; Tobias Gotterbarm; Peter R Aldinger
Journal:  Int Orthop       Date:  2012-01-12       Impact factor: 3.075

2.  Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

Authors:  Marcus R Streit; Daniel Haeussler; Thomas Bruckner; Tanja Proctor; Moritz M Innmann; Christian Merle; Tobias Gotterbarm; Stefan Weiss
Journal:  Clin Orthop Relat Res       Date:  2016-04-29       Impact factor: 4.176

Review 3.  Cementless total hip arthroplasty in rheumatoid arthritis: a systematic review of the literature.

Authors:  Rob E Zwartelé; Suzanne Witjes; H Cornelis Doets; Theo Stijnen; Rudolf G Pöll
Journal:  Arch Orthop Trauma Surg       Date:  2011-11-24       Impact factor: 3.067

Review 4.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

5.  Long-term durability of alumina ceramic heads in THA.

Authors:  Nicholas A Beckmann; Tobias Gotterbarm; Moritz M Innmann; Christian Merle; Thomas Bruckner; J Philippe Kretzer; Marcus R Streit
Journal:  BMC Musculoskelet Disord       Date:  2015-09-12       Impact factor: 2.362

6.  Failure of Polyethylene Inlays in Cementless Total Hip Arthroplasty: A Retrieval Analysis.

Authors:  Ulrike Mueller; Christoph Lee; Christian Heisel; Marc Thomsen; Rudi G Bitsch; J Philippe Kretzer
Journal:  Biomed Res Int       Date:  2016-08-31       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.