Literature DB >> 16129743

Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years.

M Pospischill1, K Knahr.   

Abstract

We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1). The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant were found. One patient needed revision surgery because of a late deep infection. In 11 hips (10.7%), the reason for revision was progressive wear of the polyethylene liner. Exchange of the acetabular component because of aseptic loosening without detectable liner wear was carried out in three hips (2.9%). After 15 years the survivorship with aseptic loosening as the definition for failure was 95.6% for the acetabular component and 100% for the femoral component.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16129743     DOI: 10.1302/0301-620X.87B9.16107

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  16 in total

1.  Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system.

Authors:  Josef Hochreiter; Giovanni Brusaferri; Klaus Kirschbichler; Katja Emmanuel
Journal:  Int Orthop       Date:  2015-08-18       Impact factor: 3.075

2.  Three-dimensional stress analysis of threaded cups - a finite element analysis.

Authors:  U Witzel; W Rieger; H Effenberger
Journal:  Int Orthop       Date:  2007-02-21       Impact factor: 3.075

3.  Total hip arthroplasty at the rothman institute.

Authors:  Matthew S Austin; Carlos A Higuera; Richard H Rothman
Journal:  HSS J       Date:  2012-04-17

4.  Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases.

Authors:  Saverio Affatato; Saverio Comitini; Matteo Fosco; Aldo Toni; Domenico Tigani
Journal:  Int Orthop       Date:  2016-02-29       Impact factor: 3.075

5.  Effect of stem alignment on long-term outcomes of total hip arthroplasty with cementless Bi-Metric femoral components.

Authors:  Takaaki Shishido; Toshiyuki Tateiwa; Yasuhito Takahashi; Toshinori Masaoka; Tsunehito Ishida; Kengo Yamamoto
Journal:  J Orthop       Date:  2018-01-16

Review 6.  Strategies for head and inlay exchange in revision hip arthroplasty.

Authors:  Martin Pospischill; Karl Knahr
Journal:  Int Orthop       Date:  2010-11-19       Impact factor: 3.075

7.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

8.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

9.  Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population.

Authors:  Peteris Studers; Danils Belajevs; Vitolds Jurkevics; Peteris Likums
Journal:  Int Orthop       Date:  2015-07-30       Impact factor: 3.075

10.  High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.

Authors:  Nikolaos A Christodoulou; Konstantinos P Dialetis; Athanasios N Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-01-05       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.