Literature DB >> 11341429

Survival analysis of cementless grit-blasted titanium total hip arthroplasties.

C Delaunay1, A I Kapandji.   

Abstract

Although about 200000 cementless Zweymüller-Alloclassic total hip arthroplasties (THAs) were carried out worldwide in the last decade, the survival analysis of these prostheses was not available in the 2000 report of the Swedish national hip arthroplasty registry. We report a prospective survivorship analysis of 200 consecutive grit-blasted cementless Alloclassic primary THAs carried out since 1988. Using surgical, clinical and radiological endpoints for the stem and the threaded cup the ten-year survivorship was 91.5% for reoperation for any cause, 96.4% for hip pain (Merle d'Aubigné score < 5 points, clinical failure), 99.4% for definite aseptic loosening (radiological failure) and 99.3% for revision for aseptic loosening. Using the Swedish registry criteria of primary osteoarthritis and revision for aseptic loosening as the endpoint, the survival rate of 99.1% at ten years for the subgroup of 157 Alloclassic THAs in osteoarthritis compares favourably with that of the best modern cemented hip replacements reported in the Swedish arthroplasty registry.

Entities:  

Mesh:

Year:  2001        PMID: 11341429     DOI: 10.1302/0301-620x.83b3.11164

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

1.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

2.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

3.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

4.  Factors influencing the revision rate of Zweymueller acetabular cup.

Authors:  H Effenberger; T Ramsauer; U Dorn; M Imhof
Journal:  Int Orthop       Date:  2004-03-31       Impact factor: 3.075

5.  [Femoral neck prostheses].

Authors:  C Stukenborg-Colsman
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

6.  [Results of cementless hip arthroplasty].

Authors:  A Grübl
Journal:  Radiologe       Date:  2006-09       Impact factor: 0.635

7.  Long-term results of cementless primary total hip arthroplasty with a threaded cup and a tapered, rectangular titanium stem in rheumatoid arthritis and osteoarthritis.

Authors:  Rob Zwartele; Anil Peters; Johannes Brouwers; Paul Olsthoorn; Ronald Brand; Cornelis Doets
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

8.  Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up.

Authors:  Petr Fulin; David Pokorny; Jan Hert; Antonin Sosna
Journal:  BMC Musculoskelet Disord       Date:  2020-05-19       Impact factor: 2.362

9.  Acid etching and plasma sterilization fail to improve osseointegration of grit blasted titanium implants.

Authors:  Mikkel Saksø; Stig S Jakobsen; Henrik Saksø; Jørgen Baas; Thomas Jakobsen; Kjeld Søballe
Journal:  Open Orthop J       Date:  2012-09-03
  9 in total