Literature DB >> 19623621

96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation.

Graham C Wiggins1, Jonathan R Polimeni, Andreas Potthast, Melanie Schmitt, Vijay Alagappan, Lawrence L Wald.   

Abstract

The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplification (g-factor) in accelerated imaging were quantitatively evaluated in phantom and human imaging and compared to a 32-channel array built on an identical helmet-shaped former and to a larger commercial 12-channel head coil. The 96-channel coil provided substantial SNR gains in the distal cortex compared to the 12- and 32-channel coils. The central SNR for the 96-channel coil was similar to the 32-channel coil for optimum SNR combination and 20% lower for root-sum-of-squares combination. There was a significant reduction in the maximum g-factor for 96 channels compared to 32; for example, the 96-channel maximum g-factor was 65% of the 32-channel value for acceleration rate 4. The performance of the array is demonstrated in highly accelerated brain images.

Entities:  

Mesh:

Year:  2009        PMID: 19623621      PMCID: PMC2915832          DOI: 10.1002/mrm.22028

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Large field-of-view real-time MRI with a 32-channel system.

Authors:  Christopher J Hardy; Robert D Darrow; Manojkumar Saranathan; Randy O Giaquinto; Yudong Zhu; Charles L Dumoulin; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

3.  Highly parallel volumetric imaging with a 32-element RF coil array.

Authors:  Yudong Zhu; Christopher J Hardy; Daniel K Sodickson; Randy O Giaquinto; Charles L Dumoulin; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Neil M Rofsky
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

4.  Effects of inductive coupling on parallel MR image reconstructions.

Authors:  Michael A Ohliger; Patrick Ledden; Charles A McKenzie; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

Authors:  Melanie Schmitt; Andreas Potthast; David E Sosnovik; Jonathan R Polimeni; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

7.  Maximizing signal-to-noise ratio in the presence of coil coupling.

Authors:  G R Duensing; H R Brooker; J R Fitzsimmons
Journal:  J Magn Reson B       Date:  1996-06

8.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

Review 9.  Theory and application of array coils in MR spectroscopy.

Authors:  S M Wright; L L Wald
Journal:  NMR Biomed       Date:  1997-12       Impact factor: 4.044

10.  Design of matching networks for low noise preamplifiers.

Authors:  A Reykowski; S M Wright; J R Porter
Journal:  Magn Reson Med       Date:  1995-06       Impact factor: 4.668

View more
  99 in total

1.  In vivo estimation of bone stiffness at the distal femur and proximal tibia using ultra-high-field 7-Tesla magnetic resonance imaging and micro-finite element analysis.

Authors:  Gregory Chang; Chamith S Rajapakse; James S Babb; Stephen P Honig; Michael P Recht; Ravinder R Regatte
Journal:  J Bone Miner Metab       Date:  2011-11-30       Impact factor: 2.626

2.  An Improved Element Design for 64-Channel Planar Imaging.

Authors:  Chieh-Wei Chang; Katherine Lynn Moody; Mary Preston McDougall
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-08       Impact factor: 1.176

3.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

4.  Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

Authors:  Martin Ott; Martin Blaimer; Felix Breuer; David Grodzki; Björn Heismann; Peter Jakob
Journal:  MAGMA       Date:  2015-10-22       Impact factor: 2.310

5.  The Role of Nonlinear Gradients in Parallel Imaging: A k-Space Based Analysis.

Authors:  Gigi Galiana; Jason P Stockmann; Leo Tam; Dana Peters; Hemant Tagare; R Todd Constable
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2012-09-26       Impact factor: 0.481

6.  Finite element analysis applied to 3-T MR imaging of proximal femur microarchitecture: lower bone strength in patients with fragility fractures compared with control subjects.

Authors:  Gregory Chang; Stephen Honig; Ryan Brown; Cem M Deniz; Kenneth A Egol; James S Babb; Ravinder R Regatte; Chamith S Rajapakse
Journal:  Radiology       Date:  2014-04-02       Impact factor: 11.105

7.  A method to assess the loss of a dipole antenna for ultra-high-field MRI.

Authors:  Gang Chen; Christopher M Collins; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2017-06-19       Impact factor: 4.668

Review 8.  Ultrafast inverse imaging techniques for fMRI.

Authors:  Fa-Hsuan Lin; Kevin W K Tsai; Ying-Hua Chu; Thomas Witzel; Aapo Nummenmaa; Tommi Raij; Jyrki Ahveninen; Wen-Jui Kuo; John W Belliveau
Journal:  Neuroimage       Date:  2012-01-21       Impact factor: 6.556

9.  Low-power adiabatic sequences for in vivo localized two-dimensional chemical shift correlated MR spectroscopy.

Authors:  Ovidiu C Andronesi; Saadallah Ramadan; Carolyn E Mountford; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2010-10-01       Impact factor: 4.668

Review 10.  Magnetic Resonance Imaging technology-bridging the gap between noninvasive human imaging and optical microscopy.

Authors:  Jonathan R Polimeni; Lawrence L Wald
Journal:  Curr Opin Neurobiol       Date:  2018-05-11       Impact factor: 6.627

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.