Literature DB >> 19616160

Growth and dissolution of an encapsulated contrast microbubble: effects of encapsulation permeability.

Kausik Sarkar1, Amit Katiyar, Pankaj Jain.   

Abstract

Gas diffusion from an encapsulated microbubble is modeled using an explicit linear relation for gas permeation through the encapsulation. Both the cases of single gas (air) and multiple gases (perfluorocarbon inside the bubble and air dissolved in surrounding liquid) are considered. An analytical expression for the dissolution time for an encapsulated air bubble is obtained; it showed that for small permeability the dissolution time increases linearly with decreasing permeability. A perfluorocarbon-filled contrast microbubble such as Definity was predicted to experience a transient growth because of air infusion before it dissolves in conformity with previous experimental findings. The growth phase occurs only for bubbles with a critical value of initial mole fraction of perfluorocarbon relative to air. With empirically obtained property values, the dissolution time of a 2.5-micron diameter (same as that of Definity), lipid-coated octafluoropropane bubble, with surface tension 25 mN/m, is predicted to be 42 min in an air-saturated medium. The properties such as shell permeability, surface tension and relative mole fraction of octafluoropropane are varied to investigate their effects on the time scales of bubble growth and dissolution, including their asymptotic scalings where appropriate. The dissolution dynamics scales with permeability, in that when the time is nondimensioanlized with permeability, curves for different permeabilities collapse on a single curve. Investigation of bubbles filled with other gases (nonoctafluoropropane perfluorocarbon and sulfur hexafluoride) indicates longer dissolution time because of lower solubility and lower diffusivity for larger gas molecules. For such micron-size encapsulated bubbles, lifetime of hours is possible only at extremely low surface tension (<1 mN/m) or at extreme oversaturation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19616160      PMCID: PMC2713870          DOI: 10.1016/j.ultrasmedbio.2009.04.010

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  27 in total

1.  Effect of filling gases on the backscatter from contrast microbubbles: theory and in vivo measurements.

Authors:  F Forsberg; R Basude; J B Liu; J Alessandro; W T Shi; N M Rawool; B B Goldberg; M A Wheatley
Journal:  Ultrasound Med Biol       Date:  1999-10       Impact factor: 2.998

2.  The effect of surface agitation on ultrasound-mediated gene transfer in vitro.

Authors:  Wen-Shiang Chen; Xiaochun Lu; Yunbo Liu; Pei Zhong
Journal:  J Acoust Soc Am       Date:  2004-10       Impact factor: 1.840

3.  Using light scattering to measure the response of individual ultrasound contrast microbubbles subjected to pulsed ultrasound in vitro.

Authors:  Jingfeng Guan; Thomas J Matula
Journal:  J Acoust Soc Am       Date:  2004-11       Impact factor: 1.840

4.  Absorption and scatter of encapsulated gas filled microspheres: theoretical considerations and some measurements.

Authors:  N de Jong; L Hoff; T Skotland; N Bom
Journal:  Ultrasonics       Date:  1992-03       Impact factor: 2.890

5.  Characterization of ultrasound contrast microbubbles using in vitro experiments and viscous and viscoelastic interface models for encapsulation.

Authors:  Kausik Sarkar; William T Shi; Dhiman Chatterjee; Flemming Forsberg
Journal:  J Acoust Soc Am       Date:  2005-07       Impact factor: 1.840

6.  Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow.

Authors:  A L Klibanov; J J Rychak; W C Yang; S Alikhani; B Li; S Acton; J R Lindner; K Ley; S Kaul
Journal:  Contrast Media Mol Imaging       Date:  2006 Nov-Dec       Impact factor: 3.161

Review 7.  Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

Authors:  Alexander L Klibanov
Journal:  Invest Radiol       Date:  2006-03       Impact factor: 6.016

8.  In vitro characterization of the subharmonic ultrasound signal from Definity microbubbles at high frequencies.

Authors:  K Cheung; O Couture; P D Bevan; E Cherin; R Williams; P N Burns; F S Foster
Journal:  Phys Med Biol       Date:  2008-02-11       Impact factor: 3.609

9.  Effects of encapsulation elasticity on the stability of an encapsulated microbubble.

Authors:  Amit Katiyar; Kausik Sarkar; Pankaj Jain
Journal:  J Colloid Interface Sci       Date:  2009-05-18       Impact factor: 8.128

10.  Lateral phase separation in lipid-coated microbubbles.

Authors:  Mark A Borden; Gary V Martinez; Josette Ricker; Nelly Tsvetkova; Marjorie Longo; Robert J Gillies; Paul A Dayton; Katherine W Ferrara
Journal:  Langmuir       Date:  2006-04-25       Impact factor: 3.882

View more
  49 in total

1.  Spatiotemporal control of micromechanics and microstructure in acoustically-responsive scaffolds using acoustic droplet vaporization.

Authors:  Mitra Aliabouzar; Christopher D Davidson; William Y Wang; Oliver D Kripfgans; Renny T Franceschi; Andrew J Putnam; J Brian Fowlkes; Brendon M Baker; Mario L Fabiilli
Journal:  Soft Matter       Date:  2020-07-22       Impact factor: 3.679

2.  Excitation threshold for subharmonic generation from contrast microbubbles.

Authors:  Amit Katiyar; Kausik Sarkar
Journal:  J Acoust Soc Am       Date:  2011-11       Impact factor: 1.840

3.  Material characterization of the encapsulation of an ultrasound contrast microbubble and its subharmonic response: strain-softening interfacial elasticity model.

Authors:  Shirshendu Paul; Amit Katiyar; Kausik Sarkar; Dhiman Chatterjee; William T Shi; Flemming Forsberg
Journal:  J Acoust Soc Am       Date:  2010-06       Impact factor: 1.840

4.  Efficacy of histotripsy combined with rt-PA in vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Himanshu Shekhar; Adam D Maxwell; Tao Peng; David D McPherson; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

5.  Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

Authors:  Marianne Gauthier; Ingrid Leguerney; Jessie Thalmensi; Mohamed Chebil; Sarah Parisot; Pierre Peronneau; Alain Roche; Nathalie Lassau
Journal:  World J Radiol       Date:  2011-03-28

6.  Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure.

Authors:  Amit Katiyar; Kausik Sarkar; Flemming Forsberg
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

7.  Effects of encapsulation damping on the excitation threshold for subharmonic generation from contrast microbubbles.

Authors:  Amit Katiyar; Kausik Sarkar
Journal:  J Acoust Soc Am       Date:  2012-11       Impact factor: 1.840

8.  The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent.

Authors:  Himanshu Shekhar; Ivy Awuor; Keri Thomas; Joshua J Rychak; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2014-04       Impact factor: 2.998

9.  Stability analysis of an encapsulated microbubble against gas diffusion.

Authors:  Amit Katiyar; Kausik Sarkar
Journal:  J Colloid Interface Sci       Date:  2009-11-20       Impact factor: 8.128

10.  Ultrasound enhanced matrix metalloproteinase-9 triggered release of contents from echogenic liposomes.

Authors:  Rahul Nahire; Shirshendu Paul; Michael D Scott; Raushan K Singh; Wallace W Muhonen; John Shabb; Kara N Gange; D K Srivastava; Kausik Sarkar; Sanku Mallik
Journal:  Mol Pharm       Date:  2012-08-15       Impact factor: 4.939

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.