Literature DB >> 19550494

Spatio-temporal Hotelling observer for signal detection from image sequences.

Luca Caucci1, Harrison H Barrett, Jeffrey J Rodriguez.   

Abstract

Detection of signals in noisy images is necessary in many applications, including astronomy and medical imaging. The optimal linear observer for performing a detection task, called the Hotelling observer in the medical literature, can be regarded as a generalization of the familiar prewhitening matched filter. Performance on the detection task is limited by randomness in the image data, which stems from randomness in the object, randomness in the imaging system, and randomness in the detector outputs due to photon and readout noise, and the Hotelling observer accounts for all of these effects in an optimal way. If multiple temporal frames of images are acquired, the resulting data set is a spatio-temporal random process, and the Hotelling observer becomes a spatio-temporal linear operator. This paper discusses the theory of the spatio-temporal Hotelling observer and estimation of the required spatio-temporal covariance matrices. It also presents a parallel implementation of the observer on a cluster of Sony PLAYSTATION 3 gaming consoles. As an example, we consider the use of the spatio-temporal Hotelling observer for exoplanet detection.

Entities:  

Mesh:

Year:  2009        PMID: 19550494      PMCID: PMC2859675          DOI: 10.1364/oe.17.010946

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  14 in total

1.  Visual detection and localization of radiographic images.

Authors:  S J Starr; C E Metz; L B Lusted; D J Goodenough
Journal:  Radiology       Date:  1975-09       Impact factor: 11.105

2.  Objective assessment of image quality. IV. Application to adaptive optics.

Authors:  Harrison H Barrett; Kyle J Myers; Nicholas Devaney; Christopher Dainty
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-12       Impact factor: 2.129

3.  Estimation receiver operating characteristic curve and ideal observers for combined detection/estimation tasks.

Authors:  Eric Clarkson
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

4.  One-shot estimate of MRMC variance: AUC.

Authors:  Brandon D Gallas
Journal:  Acad Radiol       Date:  2006-03       Impact factor: 3.173

5.  Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware.

Authors:  Marc Kachelriess; Michael Knaup; Olivier Bockenbach
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

6.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

7.  Efficiency of the human observer detecting random signals in random backgrounds.

Authors:  Subok Park; Eric Clarkson; Matthew A Kupinski; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2005-01       Impact factor: 2.129

8.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability.

Authors:  C K Abbey; H H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-03       Impact factor: 2.129

9.  Effect of noise correlation on detectability of disk signals in medical imaging.

Authors:  K J Myers; H H Barrett; M C Borgstrom; D D Patton; G W Seeley
Journal:  J Opt Soc Am A       Date:  1985-10       Impact factor: 2.129

10.  Signal and noise transfer in spatiotemporal quantum-based imaging systems.

Authors:  Reza Akbarpour; Saul N Friedman; Jeffrey H Siewerdsen; John D Neary; Ian A Cunningham
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

View more
  4 in total

1.  Spatiotemporal correlation of optical coherence tomography in-vivo images of rabbit airway for the diagnosis of edema.

Authors:  DongYel Kang; Alex Wang; Veronika Volgger; Zhongping Chen; Brian J F Wong
Journal:  J Biomed Opt       Date:  2015-07       Impact factor: 3.170

2.  Uniform, optimal signal processing of mapped deep-sequencing data.

Authors:  Vibhor Kumar; Masafumi Muratani; Nirmala Arul Rayan; Petra Kraus; Thomas Lufkin; Huck Hui Ng; Shyam Prabhakar
Journal:  Nat Biotechnol       Date:  2013-06-16       Impact factor: 54.908

3.  Numerical Surrogates for Human Observers in Myocardial Motion Evaluation From SPECT Images.

Authors:  Thibault Marin; Mahdi M Kalayeh; Felipe M Parages; Jovan G Brankov
Journal:  IEEE Trans Med Imaging       Date:  2013-08-22       Impact factor: 10.048

4.  On Advanced Estimation Techniques for Exoplanet Detection and Characterization Using Ground-based Coronagraphs.

Authors:  Peter R Lawson; Lisa Poyneer; Harrison Barrett; Richard Frazin; Luca Caucci; Nicholas Devaney; Lars Furenlid; Szymon Gładysz; Olivier Guyon; John Krist; Jérôme Maire; Christian Marois; Dimitri Mawet; David Mouillet; Laurent Mugnier; Iain Pearson; Marshall Perrin; Laurent Pueyo; Dmitry Savransky
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-07-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.