Literature DB >> 23981533

Numerical Surrogates for Human Observers in Myocardial Motion Evaluation From SPECT Images.

Thibault Marin, Mahdi M Kalayeh, Felipe M Parages, Jovan G Brankov.   

Abstract

In medical imaging, the gold standard for image-quality assessment is a task-based approach in which one evaluates human observer performance for a given diagnostic task (e.g., detection of a myocardial perfusion or motion defect). To facilitate practical task-based image-quality assessment, model observers are needed as approximate surrogates for human observers. In cardiac-gated SPECT imaging, diagnosis relies on evaluation of the myocardial motion as well as perfusion. Model observers for the perfusion-defect detection task have been studied previously, but little effort has been devoted toward development of a model observer for cardiac-motion defect detection. In this work, we describe two model observers for predicting human observer performance in detection of cardiac-motion defects. Both proposed methods rely on motion features extracted using previously reported deformable mesh model for myocardium motion estimation. The first method is based on a Hotelling linear discriminant that is similar in concept to that used commonly for perfusion-defect detection. In the second method, based on relevance vector machines (RVM) for regression, we compute average human observer performance by first directly predicting individual human observer scores, and then using multi reader receiver operating characteristic analysis. Our results suggest that the proposed RVM model observer can predict human observer performance accurately, while the new Hotelling motion-defect detector is somewhat less effective.

Entities:  

Mesh:

Year:  2013        PMID: 23981533      PMCID: PMC4148467          DOI: 10.1109/TMI.2013.2279517

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging.

Authors:  P H Pretorius; M A King; B M Tsui; K J LaCroix; W Xia
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Myocardial perfusion SPECT using a rotating multi-segment slant-hole collimator.

Authors:  Chi Liu; Jingyan Xu; Benjamin M W Tsui
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  Deformable left-ventricle mesh model for motion-compensated filtering in cardiac gated SPECT.

Authors:  Thibault Marin; Jovan G Brankov
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 5.  Automated quantification of myocardial ischemia and wall motion defects by use of cardiac SPECT polar mapping and 4-dimensional surface rendering.

Authors:  G Sharat Lin; Horace H Hines; Genine Grant; Kimberly Taylor; Carl Ryals
Journal:  J Nucl Med Technol       Date:  2006-03

6.  An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images.

Authors:  A D Achtert; M A King; S T Dahlberg; P H Pretorius; K J LaCroix; B M Tsui
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

7.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

8.  Myocardial perfusion SPECT reconstruction: receiver operating characteristic comparison of CAD detection accuracy of filtered backprojection reconstruction with all of the clinical imaging information available to readers and solely stress slices iteratively reconstructed with combined compensation.

Authors:  P Hendrik Pretorius; Michael A King; Howard C Gifford; Seth T Dahlberg; Frederick Spencer; Ellen Simon; Jason Rashkin; Naomi Botkin; William Berndt; Manoj V Narayanan; Jeffrey A Leppo
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

9.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.

Authors:  H C Gifford; M A King; D J de Vries; E J Soares
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

10.  Measuring regional changes in the diastolic deformation of the left ventricle of SHR rats using microPET technology and hyperelastic warping.

Authors:  Alexander I Veress; Jeffrey A Weiss; Ronald H Huesman; Bryan W Reutter; Scott E Taylor; Arek Sitek; Bing Feng; Yongfeng Yang; Grant T Gullberg
Journal:  Ann Biomed Eng       Date:  2008-04-24       Impact factor: 3.934

View more
  3 in total

1.  Lack of agreement between radiologists: implications for image-based model observers.

Authors:  Juhun Lee; Robert M Nishikawa; Ingrid Reiser; Margarita L Zuley; John M Boone
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-03

2.  Full receiver operating characteristic curve estimation using two alternative forced choice studies.

Authors:  Francesc Massanes; Jovan G Brankov
Journal:  J Med Imaging (Bellingham)       Date:  2016-02-05

3.  Task-based assessment of binned and list-mode SPECT systems.

Authors:  Md Ashequr Rahman; Abhinav K Jha
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15
  3 in total