Literature DB >> 19544787

Investigation of lung nodule detectability in low-dose 320-slice computed tomography.

J D Silverman1, N S Paul, J H Siewerdsen.   

Abstract

Low-dose imaging protocols in chest CT are important in the screening and surveillance of suspicious and indeterminate lung nodules. Techniques that maintain nodule detectability yet permit dose reduction, particularly for large body habitus, were investigated. The objective of this study was to determine the extent to which radiation dose can be minimized while maintaining diagnostic performance through knowledgeable selection of reconstruction techniques. A 320-slice volumetric CT scanner (Aquilion ONE, Toshiba Medical Systems) was used to scan an anthropomorphic phantom at doses ranging from approximately 0.1 mGy up to that typical of low-dose CT (LDCT, approximately 5 mGy) and diagnostic CT (approximately 10 mGy). Radiation dose was measured via Farmer chamber and MOSFET dosimetry. The phantom presented simulated nodules of varying size and contrast within a heterogeneous background, and chest thickness was varied through addition of tissue-equivalent bolus about the chest. Detectability of a small solid lung nodule (3.2 mm diameter, -37 HU, typically the smallest nodule of clinical significance in screening and surveillance) was evaluated as a function of dose, patient size, reconstruction filter, and slice thickness by means of nine-alternative forced-choice (9AFC) observer tests to quantify nodule detectability. For a given reconstruction filter, nodule detectability decreased sharply below a threshold dose level due to increased image noise, especially for large body size. However, nodule detectability could be maintained at lower doses through knowledgeable selection of (smoother) reconstruction filters. For large body habitus, optimal filter selection reduced the dose required for nodule detection by up to a factor of approximately 3 (from approximately 3.3 mGy for sharp filters to approximately 1.0 mGy for the optimal filter). The results indicate that radiation dose can be reduced below the current low-dose (5 mGy) and ultralow-dose (1 mGy) levels with knowledgeable selection of reconstruction parameters. Image noise, not spatial resolution, was found to be the limiting factor in detection of small lung nodules. Therefore, the use of smoother reconstruction filters may permit lower-dose protocols without trade-off in diagnostic performance.

Entities:  

Mesh:

Year:  2009        PMID: 19544787      PMCID: PMC2832029          DOI: 10.1118/1.3112363

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Pulmonary nodules: preliminary experience with three-dimensional evaluation.

Authors:  Marie-Pierre Revel; Catherine Lefort; Alvine Bissery; Marie Bienvenu; Laetitia Aycard; Gilles Chatellier; Guy Frija
Journal:  Radiology       Date:  2004-05       Impact factor: 11.105

3.  Statistical limitations in transaxial tomography.

Authors:  H H Barrett; S K Gordon; R S Hershel
Journal:  Comput Biol Med       Date:  1976-10       Impact factor: 4.589

4.  Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: beyond CTDI100.

Authors:  Robert L Dixon; Adam C Ballard
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

5.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

6.  Investigating the low-dose limits of multidetector CT in lung nodule surveillance.

Authors:  N S Paul; J H Siewerdsen; D Patsios; T B Chung
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

7.  Small incidental pulmonary nodules: how useful is short-term interval CT follow-up?

Authors:  Nitra Piyavisetpat; Suzanne L Aquino; Peter F Hahn; Elkan F Halpern; James H Thrall
Journal:  J Thorac Imaging       Date:  2005-02       Impact factor: 3.000

8.  Small pulmonary nodules: evaluation with repeat CT--preliminary experience.

Authors:  D F Yankelevitz; R Gupta; B Zhao; C I Henschke
Journal:  Radiology       Date:  1999-08       Impact factor: 11.105

9.  Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.

Authors:  M Remy-Jardin; J Remy; F Giraud; C H Marquette
Journal:  Radiology       Date:  1993-05       Impact factor: 11.105

10.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007
View more
  15 in total

1.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Influence of difference in cross-sectional dose profile in a CTDI phantom on X-ray CT dose estimation: a Monte Carlo study.

Authors:  Tomonobu Haba; Shuji Koyama; Yoshihiro Ida
Journal:  Radiol Phys Technol       Date:  2013-11-24

3.  Radiation dose threshold for coronary artery calcium score with MDCT: how low can you go?

Authors:  Tom D Newton; Hatem Mehrez; Kelly Wong; Ravi Menezes; Bernd J Wintersperger; Andrew Crean; Elsie Nguyen; Narinder Paul
Journal:  Eur Radiol       Date:  2011-06-03       Impact factor: 5.315

4.  A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom.

Authors:  Saul N Friedman; George S K Fung; Jeffrey H Siewerdsen; Benjamin M W Tsui
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

5.  General equations for optimal selection of diagnostic image acquisition parameters in clinical X-ray imaging.

Authors:  Xiaoming Zheng
Journal:  Radiol Phys Technol       Date:  2017-08-18

6.  Observer-independent nodule-detectability index for low-dose lung cancer screening CT: a pilot study.

Authors:  Masaki Ohkubo; Shinichi Wada; Satoshi Kanai; Kazuhiro Ishikawa; Janaka C Marasinghe; Toru Matsumoto
Journal:  Radiol Phys Technol       Date:  2013-06-09

Review 7.  Recent technological and application developments in computed tomography and magnetic resonance imaging for improved pulmonary nodule detection and lung cancer staging.

Authors:  Jessica C Sieren; Yoshiharu Ohno; Hisanobu Koyama; Kazuro Sugimura; Geoffrey McLennan
Journal:  J Magn Reson Imaging       Date:  2010-12       Impact factor: 4.813

8.  The PROgnostic Value of unrequested Information in Diagnostic Imaging (PROVIDI) Study: rationale and design.

Authors:  M J A Gondrie; W P Th M Mali; C F M Buckens; P C A Jacobs; D E Grobbee; Y van der Graaf
Journal:  Eur J Epidemiol       Date:  2010-10-02       Impact factor: 8.082

9.  First experience of efficacy and radiation exposure in 320-detector row CT fluoroscopy-guided interventions.

Authors:  Shota Yamamoto; Tomohiro Matsumoto; Satoshi Suda; Kosuke Tomita; Shunsuke Kamei; Kazunobu Hashida; Yutaka Imai; Kazuyuki Endo; Katsuki Murakami; Terumitsu Hasebe
Journal:  Br J Radiol       Date:  2021-02-05       Impact factor: 3.039

10.  Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction.

Authors:  John W Garrett; Yinsheng Li; Ke Li; Guang-Hong Chen
Journal:  Med Phys       Date:  2018-04-01       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.