Literature DB >> 15128991

Pulmonary nodules: preliminary experience with three-dimensional evaluation.

Marie-Pierre Revel1, Catherine Lefort, Alvine Bissery, Marie Bienvenu, Laetitia Aycard, Gilles Chatellier, Guy Frija.   

Abstract

PURPOSE: To evaluate software designed to calculate pulmonary nodule volume in three dimensions.
MATERIALS AND METHODS: Fifty-four solid noncalcified pulmonary nodules measuring 5-18 mm in diameter were studied with computed tomographic (CT) volumetric software. Baseline CT examinations were performed for various indications by using four-detector row multisection CT units, 1.25- or 2.50-mm sections, and a standard reconstruction algorithm. The percentage of successful nodule segmentations, as well as intraobserver variability, interreader agreement, and global repeatability of calculated volumes, was determined on the basis of consecutive measurements performed three times by three different radiologists by using the Bland and Altman method. The software was used to calculate the doubling time of 22 nodules for which a final diagnosis and comparable CT scans were available.
RESULTS: Fifty-two (96%) of the 54 nodules were successfully segmented, allowing their volume to be calculated. Repeatability was high: There was no variation in the nine measurements of 35 (67%) of the 52 nodules. The coefficient of variation for the remaining 17 nodules (33%) was 2.26%. Bland and Altman 95% limits of acceptability, calculated on the basis of log-transformed data, yielded a maximum software measurement error of 6.38% of the previous volume measurement. Doubling time ranged from 4 to 188 years for the 13 benign nodules and from 37 to 216 days for the nine malignant nodules.
CONCLUSION: Software volumetric analysis yielded repeatable estimates for 96% of the nodules examined. All software-calculated doubling times were in keeping with the benign or malignant nature of the nodules.

Mesh:

Year:  2004        PMID: 15128991     DOI: 10.1148/radiol.2312030241

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  47 in total

1.  Evaluating the growth of pulmonary nodular ground-glass opacity on CT: comparison of volume rendering and thin slice images.

Authors:  Mingzhu Liang; Xueguo Liu; Weidong Li; Kunwei Li; Xiangmeng Chen; Guojie Wang; Kai Chen; Jinxin Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2011-12-16

2.  Zone of transition: a potential source of error in tumor volume estimation.

Authors:  Lijuan Zhang; David F Yankelevitz; Claudia I Henschke; Artit C Jirapatnakul; Anthony P Reeves; Darryl Carter
Journal:  Radiology       Date:  2010-08       Impact factor: 11.105

3.  Solitary pulmonary nodule: detection and management.

Authors:  S Diederich; M Das
Journal:  Cancer Imaging       Date:  2006-10-31       Impact factor: 3.909

4.  Insertion of virtual pulmonary nodules in CT data of the chest: development of a software tool.

Authors:  Hoen-oh Shin; Matthias Blietz; Bernd Frericks; Stefan Baus; Dagmar Savellano; Michael Galanski
Journal:  Eur Radiol       Date:  2006-07-04       Impact factor: 5.315

5.  Effect of blood vessels on measurement of nodule volume in a chest phantom.

Authors:  Jane P Ko; Rachel Marcus; Elan Bomsztyk; James S Babb; Cornel Stefanescu; Manmeen Kaur; David P Naidich; Henry Rusinek
Journal:  Radiology       Date:  2006-04       Impact factor: 11.105

Review 6.  Management of an incidentally discovered pulmonary nodule.

Authors:  Catherine Beigelman-Aubry; Catherine Hill; Philippe A Grenier
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

7.  The effect of lung volume on nodule size on CT.

Authors:  Iva Petkovska; Matthew S Brown; Jonathan G Goldin; Hyun J Kim; Michael F McNitt-Gray; Fereidoun G Abtin; Raffi J Ghurabi; Denise R Aberle
Journal:  Acad Radiol       Date:  2007-04       Impact factor: 3.173

8.  Automated volumetry of pulmonary nodules on multidetector CT: influence of slice thickness, reconstruction algorithm and tube current. Preliminary results.

Authors:  A R Larici; M L Storto; M Torge; M Mereu; F Molinari; F Maggi; L Bonomo
Journal:  Radiol Med       Date:  2008-02-25       Impact factor: 3.469

Review 9.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

10.  Imprecision in automated volume measurements of pulmonary nodules and its effect on the level of uncertainty in volume doubling time estimation.

Authors:  Paul J Nietert; James G Ravenel; William M Leue; James V Miller; Katherine K Taylor; Elizabeth S Garrett-Mayer; Gerard A Silvestri
Journal:  Chest       Date:  2009-01-13       Impact factor: 9.410

View more