The acute effects of running on blood pressure estimation using pulse transit time in normotensive subjects.

Mico Yee-Man Wong1, Emma Pickwell-MacPherson, Yuan-Ting Zhang.   

Abstract

Pulse transit time (PTT) is a potential parameter for cuffless blood pressure (BP) estimation. Since exercise induces changes in arterial properties that can influence the relationship between BP and PTT, we investigate whether PTT can be used to estimate BP after successive bouts of exercise. PTT-foot, PTT-peak (time intervals from the peak of electrocardiogram R-wave to the foot and peak of photoplethysmogram, respectively) and BP of 41 normotensive subjects (aged 25 +/- 4 years) were measured in the first test. A repeatability test was then conducted on 14 subjects after 6 months. Each test included two periods of running on the treadmill at 10 and 8 km/h (with a rest in between). In both tests, systolic BP (SBP) was closely correlated with PTT-foot and PTT-peak. For each subject, the best fit linear relationships between SBP and PTTs were determined over all phases of each test. The differences between the linear fits and measured data were greater after the second period of running for all subjects in both tests. This implied that the relationships started to change after the second period of running. When SBP in the repeatability test was predicted using the linear regression coefficients from the first test, the linear fit after the first period of exercise was still better than after the second. The repeated observations in both tests suggest that PTT is a potential parameter for cuffless BP estimation after one period of exercise, but would need re-calibration (relationship between BP and PTTs) for measurements after successive phases of exercise.

Entities:  

Mesh:

Year:  2009        PMID: 19543907     DOI: 10.1007/s00421-009-1112-8

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  21 in total

1.  Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults.

Authors:  W B White; Y A Anwar
Journal:  Blood Press Monit       Date:  2001-04       Impact factor: 1.444

2.  Validation of the Omron HEM-907 device for blood pressure measurement.

Authors:  Mohamed A El Assaad; Jirar A Topouchian; Bernadette M Darné; Roland G Asmar
Journal:  Blood Press Monit       Date:  2002-08       Impact factor: 1.444

3.  A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states.

Authors:  Jong Yong A Foo; Stephen J Wilson
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

4.  Unconstrained pulse transit time measurement system for computer users.

Authors:  Juwan Park; Yongkyu Lim; Youngjoon Chee; Jungsoo Kim; Kokeun Kim; Kwang Suk Park
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

5.  Effect of acute sprint interval exercise on central and peripheral artery distensibility in young healthy males.

Authors:  Mark Rakobowchuk; Melanie I Stuckey; Philip J Millar; Lindsay Gurr; Maureen Jane Macdonald
Journal:  Eur J Appl Physiol       Date:  2009-01-06       Impact factor: 3.078

6.  The covariation of blood pressure and pulse transit time in hypertensive patients.

Authors:  R A Allen; J A Schneider; D M Davidson; M A Winchester; C B Taylor
Journal:  Psychophysiology       Date:  1981-05       Impact factor: 4.016

7.  Aortic-radial pulse transit time and ECG Q-wave to radial pulse wave interval as indices of beat-by-beat blood pressure change.

Authors:  M H Pollak; P A Obrist
Journal:  Psychophysiology       Date:  1983-01       Impact factor: 4.016

8.  The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise.

Authors:  G V Marie; C R Lo; J Van Jones; D W Johnston
Journal:  Psychophysiology       Date:  1984-09       Impact factor: 4.016

9.  Effects of nitric oxide synthase inhibitor on decrease in peripheral arterial stiffness with acute low-intensity aerobic exercise.

Authors:  Jun Sugawara; Seiji Maeda; Takeshi Otsuki; Takumi Tanabe; Ryuichi Ajisaka; Mitsuo Matsuda
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-07-29       Impact factor: 4.733

10.  Arterial stiffness and wave reflection following exercise in resistance-trained men.

Authors:  Kevin S Heffernan; Sae Young Jae; George H Echols; Nicolas R Lepine; Bo Fernhall
Journal:  Med Sci Sports Exerc       Date:  2007-05       Impact factor: 5.411

View more
  9 in total

1.  Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation.

Authors:  Heidi Schmalgemeier; Thomas Bitter; Stephan Bartsch; Kevin Bullert; Thomas Fischbach; Siegfried Eckert; Dieter Horstkotte; Olaf Oldenburg
Journal:  Sleep Breath       Date:  2011-10-29       Impact factor: 2.816

2.  The effects of pre-ejection period on post-exercise systolic blood pressure estimation using the pulse arrival time technique.

Authors:  Mico Yee Man Wong; Emma Pickwell-MacPherson; Yuan Ting Zhang; Jack C Y Cheng
Journal:  Eur J Appl Physiol       Date:  2010-09-08       Impact factor: 3.078

3.  Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne-Stokes respiration undergoing adaptive servoventilation therapy.

Authors:  Jens Spießhöfer; Jessica Heinrich; Thomas Bitter; Christina Efken; Roman Lehmann; Siegfried Eckert; Dieter Horstkotte; Olaf Oldenburg
Journal:  Sleep Breath       Date:  2013-09-24       Impact factor: 2.816

4.  Development and Validation of a Novel Cuff-Less Blood Pressure Monitoring Device.

Authors:  Naoki Watanabe; Yasuko K Bando; Taiji Kawachi; Hiroshi Yamakita; Kouki Futatsuyama; Yoshikazu Honda; Hisae Yasui; Kazuyuki Nishimura; Takahiro Kamihara; Takahiro Okumura; Hideki Ishii; Takahisa Kondo; Toyoaki Murohara
Journal:  JACC Basic Transl Sci       Date:  2017-12-25

5.  Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches.

Authors:  Syed Ghufran Khalid; Jufen Zhang; Fei Chen; Dingchang Zheng
Journal:  J Healthc Eng       Date:  2018-10-23       Impact factor: 2.682

6.  Beat-to-beat blood pressure measurement using a cuffless device does not accurately reflect invasive blood pressure.

Authors:  Mohammed A Moharram; Luke C Wilson; Michael Ja Williams; Sean Coffey
Journal:  Int J Cardiol Hypertens       Date:  2020-04-14

7.  Blood pressure altering method affects correlation with pulse arrival time.

Authors:  Sondre Heimark; Ole Marius H Rindal; Trine M Seeberg; Alexey Stepanov; Elin S Boysen; Kasper G Bøtker-Rasmussen; Nina K Mobæk; Camilla L Søraas; Aud E Stenehjem; Fadl Elmula M Fadl Elmula; Bård Waldum-Grevbo
Journal:  Blood Press Monit       Date:  2022-04-01       Impact factor: 1.444

8.  A Revised Point-to-Point Calibration Approach with Adaptive Errors Correction to Weaken Initial Sensitivity of Cuff-Less Blood Pressure Estimation.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

9.  Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure.

Authors:  Syunsuke Yamanaka; Koji Morikawa; Hiroshi Morita; Ji Young Huh; Osamu Yamamura
Journal:  Front Med Technol       Date:  2021-07-27
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.