Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments.

Y Yahata1, T Yoneyama, Y Hayashi, A Ebihara, H Doi, T Hanawa, H Suda.   

Abstract

AIM: To investigate the effect of heat treatment on the bending properties of nickel-titanium endodontic instruments in relation to their transformation behaviour.
METHODOLOGY: Nickel-titanium super-elastic alloy wire (1.00 mm Ø) was processed into a conical shape with a 0.30 mm diameter tip and 0.06 taper. The heat treatment temperature was set at 440 or 500 degrees C for a period of 10 or 30 min. Nonheat-treated specimens were used as controls. The phase transformation behaviour was examined using differential scanning calorimetry. A cantilever-bending test was used to evaluate the bending properties of the specimens. Data were analyzed by ANOVA and the Tukey-Kramer test (P = 0.05).
RESULTS: The transformation temperature was higher for each heat treatment condition compared with the control. Two clear thermal peaks were observed for the heat treatment at 440 degrees C. The specimen heated at 440 degrees C for 30 min exhibited the highest temperatures for M(s) and A(f), with subsequently lower temperatures observed for specimens heated at 440 degrees C for 10 min, 500 degrees C for 30 min, 500 degrees C for 10 min, and control specimens. The sample heated at 440 degrees C for 30 min had the lowest bending load values (P < 0.05), both in the elastic range (0.5 mm deflection) and in the super-elastic range (2.0 mm deflection). The influence of heat treatment time was less than that of heat treatment temperature.
CONCLUSIONS: Change in the transformation behaviour by heat treatment may be effective in increasing the flexibility of nickel-titanium endodontic instruments.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19467049     DOI: 10.1111/j.1365-2591.2009.01563.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  22 in total

1.  Performance of NiTi endodontic instrument under different temperatures.

Authors:  Ahmed Jamleh; Yoshio Yahata; Arata Ebihara; Amre R Atmeh; Turki Bakhsh; Hideaki Suda
Journal:  Odontology       Date:  2015-08-22       Impact factor: 2.634

2.  [Construction and mechanical analysis of finite element model for bending property of controlled memory wire nickel-titanium rotary file].

Authors:  H Y Fu; F F Wang; X M Hou
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-02-18

3.  Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files.

Authors:  Tyler Sobotkiewicz; Xiangya Huang; Markus Haapasalo; Christophe Mobuchon; Ahmed Hieawy; Jinghao Hu; Huimin Zhou; Zhejun Wang; Ya Shen
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

4.  Micro-computed tomography evaluation of dentinal microcracks following canal preparation with thermomechanically heat-treated engine-driven files.

Authors:  Sharmini Arumugam; Hsu Zenn Yew; Safura Anita Baharin; Jasmina Qamaruz Zaman; Andanastuti Muchtar; Shalini Kanagasingam
Journal:  Aust Endod J       Date:  2021-05-06       Impact factor: 1.719

5.  Topographic Analysis of HyFlex(®) Controlled Memory Nickel-Titanium Files.

Authors:  Dina Al-Sudani
Journal:  J Int Oral Health       Date:  2014 Nov-Dec

6.  Treatment of Necrotic Teeth Using Two Engine-Driven Systems and Patient's Postoperative Pain: A Double-Blind Clinical Trial.

Authors:  Vahid Zand; Amin Salem Milani; Ayla Hassani Dehkharghani; Mahdi Rahbar; Pardis Tehranchi
Journal:  Iran Endod J       Date:  2016

7.  The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu
Journal:  Restor Dent Endod       Date:  2017-11-02

8.  Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature.

Authors:  Wafaa A Khalil; Zuhair S Natto
Journal:  Restor Dent Endod       Date:  2019-04-26

9.  Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization.

Authors:  Üreyen Kaya Bulem; Ayse Diljin Kececi; Hilmi Egemen Guldas
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

10.  Fracture Resistance of K3 Nickel-Titanium Files Made from Different Thermal Treatments.

Authors:  JinWook Choi; Soram Oh; Yu-Chan Kim; Kwang-Koo Jee; KeeYeon Kum; SeokWoo Chang
Journal:  Bioinorg Chem Appl       Date:  2016-11-14       Impact factor: 7.778