Literature DB >> 19457490

Optimization of intravascular shear stress assessment in vivo.

Lisong Ai1, Hongyu Yu1, Wakako Takabe1, Anna Paraboschi1, Fei Yu1, E S Kim2, Rongsong Li1, Tzung K Hsiai3.   

Abstract

The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the abdominal aorta of the New Zealand white (NZW) rabbits. Theoretical and computational fluid dynamics (CFD) analyses were performed. Fluoroscope and angiogram provided the geometry of aorta, and the Doppler ultrasound system provided the pulsatile flow velocity for the boundary conditions. The physical parameters governing the shear stress assessment in NZW rabbits included (1) the position and distance from which the MEMS sensors were mounted to the terminal end of coaxial wire or the entrance length, (L(e)), (2) diameter ratios of aorta to the coaxial wire (D(aorta) /D(coaxial wire)=1.5-9.5), and (3) the range of Reynolds numbers (116-1550). At an aortic diameter of 2.4mm and a maximum Reynolds number of 212 (a mean Reynolds number of 64.2), the time-averaged shear stress (tau(ave)) was computed to be 10.06 dyn cm(-2) with a systolic peak at 33.18 dyn cm(-2). In the presence of a coaxial wire (D(aorta)/D(coaxial wire)=6 and L(e)=1.18 cm), the tau(ave) value increased to 15.54 dyn cm(-2) with a systolic peak at 51.25 dyn cm(-2). Real-time intravascular shear stress assessment by the MEMS sensor revealed an tau(ave) value of 11.92 dyn cm(-2) with a systolic peak at 47.04 dyn cm(-2). The difference between CFD and experimental tau(ave) was 18.5%. These findings provided important insights into packaging the MEMS sensors to optimize in vivo shear stress assessment.

Entities:  

Mesh:

Year:  2009        PMID: 19457490      PMCID: PMC2777988          DOI: 10.1016/j.jbiomech.2009.04.021

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  Effect of exercise on hemodynamic conditions in the abdominal aorta.

Authors:  C A Taylor; T J Hughes; C K Zarins
Journal:  J Vasc Surg       Date:  1999-06       Impact factor: 4.268

2.  Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.

Authors:  J W Doucette; P D Corl; H M Payne; A E Flynn; M Goto; M Nassi; J Segal
Journal:  Circulation       Date:  1992-05       Impact factor: 29.690

3.  A model of growth and rupture of abdominal aortic aneurysm.

Authors:  K Y Volokh; D A Vorp
Journal:  J Biomech       Date:  2008-02-05       Impact factor: 2.712

4.  Catheter obstruction effect on pulsatile flow rate--pressure drop during coronary angioplasty.

Authors:  R K Banerjee; L H Back; M R Back; Y I Cho
Journal:  J Biomech Eng       Date:  1999-06       Impact factor: 2.097

5.  Pulsatile flow in a catheterised artery.

Authors:  D A MacDonald
Journal:  J Biomech       Date:  1986       Impact factor: 2.712

6.  The effect of wall distensibility on flow in a two-dimensional end-to-side anastomosis.

Authors:  D A Steinman; C R Ethier
Journal:  J Biomech Eng       Date:  1994-08       Impact factor: 2.097

7.  Estimated mean flow resistance increase during coronary artery catheterization.

Authors:  L H Back
Journal:  J Biomech       Date:  1994-02       Impact factor: 2.712

8.  Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements.

Authors:  Abhijit Sinha Roy; Rupak K Banerjee; Lloyd H Back; Martin R Back; Saeb Khoury; Ronald W Millard
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-02-25       Impact factor: 4.733

9.  Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis.

Authors:  M Lei; J P Archie; C Kleinstreuer
Journal:  J Vasc Surg       Date:  1997-04       Impact factor: 4.268

10.  Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis.

Authors:  Abhijit Sinha Roy; Lloyd H Back; Rupak K Banerjee
Journal:  J Biomech       Date:  2006       Impact factor: 2.712

View more
  6 in total

1.  Flexible and waterproof micro-sensors to uncover zebrafish circadian rhythms: The next generation of cardiac monitoring for drug screening.

Authors:  Xiaoxiao Zhang; Tyler Beebe; Nelon Jen; Chia-An Lee; Yuchong Tai; Tzung K Hsiai
Journal:  Biosens Bioelectron       Date:  2015-04-14       Impact factor: 10.618

2.  Real-time assessment of flow reversal in an eccentric arterial stenotic model.

Authors:  Lisong Ai; Lequan Zhang; Wangde Dai; Changhong Hu; K Kirk Shung; Tzung K Hsiai
Journal:  J Biomech       Date:  2010-07-23       Impact factor: 2.712

3.  MEMS thermal sensors to detect changes in heat transfer in the pre-atherosclerotic regions of fat-fed New Zealand white rabbits.

Authors:  Fei Yu; Lisong Ai; Wangde Dai; Nora Rozengurt; Hongyu Yu; Tzung K Hsiai
Journal:  Ann Biomed Eng       Date:  2011-03-05       Impact factor: 3.934

4.  Elevated electrochemical impedance in the endoluminal regions with high shear stress: implication for assessing lipid-rich atherosclerotic lesions.

Authors:  Fei Yu; Juhyun Lee; Nelson Jen; Xiang Li; Qian Zhang; Rui Tang; Qifa Zhou; Eun S Kim; Tzung K Hsiai
Journal:  Biosens Bioelectron       Date:  2012-12-20       Impact factor: 10.618

5.  Atrial fibrillation pacing decreases intravascular shear stress in a New Zealand white rabbit model: implications in endothelial function.

Authors:  Nelson Jen; Fei Yu; Juhyun Lee; Steve Wasmund; Xiaohu Dai; Christina Chen; Pai Chawareeyawong; Yongmo Yang; Rongsong Li; Mohamed H Hamdan; Tzung K Hsiai
Journal:  Biomech Model Mechanobiol       Date:  2012-09-15

6.  Prospective nonrandomized comparison of quality of life and recurrence between high ligation and stripping and radiofrequency ablation for varicose veins.

Authors:  Hyung Sub Park; Yujin Kwon; Bang Wool Eom; Taeseung Lee
Journal:  J Korean Surg Soc       Date:  2012-12-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.