Literature DB >> 1572046

Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.

J W Doucette1, P D Corl, H M Payne, A E Flynn, M Goto, M Nassi, J Segal.   

Abstract

BACKGROUND: An improved intravascular ultrasonic Doppler device could aid the clinical assessment of coronary hemodynamics. We evaluated a new device consisting of a 12-MHz piezoelectric transducer integrated onto the tip of a 0.018-in. flexible, steerable angioplasty guide wire. METHODS AND
RESULTS: Doppler spectra were recorded in model tubes with pulsatile blood flow and in-line electromagnetic flowmeter. In four straight tubes (i.d., 0.79-4.76 mm), the time average of spectral peak velocity (APV) was linearly related to blood flow (QEMF) (r2 greater than or equal to 0.98 for each tube). A Doppler-derived quantitative flow estimate (QD) was calculated as the product of vessel cross-sectional area and mean velocity, with mean velocity estimated as 0.5 x APV. The slope of QD versus QEMF for the four tubes was near unity. APV was less accurate in a 7.94-mm straight tube and in tortuous segments. In four dogs, the left circumflex coronary artery (LCx) was perfused from the femoral artery via a cannula with in-line electromagnetic flowmeter. Good-quality signals were obtained in proximal and distal LCx vessels 3.3-1.2 mm in diameter. APV varied linearly with QEMF (r2 greater than or equal to 0.99 in the cannula, r2 = 0.93-0.99 in proximal LCx, and r2 = 0.86-0.99 in distal LCx). QD was calculated by quantitative angiography to determine proximal LCx diameter. For all dogs combined, the slope of QD versus QEMF was 0.95 in the cannula and 0.85 in the proximal LCx.
CONCLUSIONS: The Doppler guide wire measures phasic flow velocity patterns and linearly tracks changes in flow rate in small, straight coronary arteries. It should facilitate measurement of phasic coronary flow velocity during coronary angiography and angioplasty.

Entities:  

Mesh:

Year:  1992        PMID: 1572046     DOI: 10.1161/01.cir.85.5.1899

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  139 in total

1.  Functional assessment of coronary artery stenosis by doppler derived absolute and relative coronary blood flow velocity reserve in comparison with (99m)Tc MIBI SPECT.

Authors:  H J Verberne; J J Piek; R A van Liebergen; K T Koch; J M Schroeder-Tanka; E A van Royen
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  Effect of stenting on coronary flow velocity reserve: comparison of coil and tubular stents.

Authors:  C J Vrints; M J Claeys; J Bosmans; V Conraads; J P Snoeck
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

3.  Adaptive mechanisms of arterial and venous coronary bypass grafts to an increase in flow demand.

Authors:  O Gurné; P Chenu; M Buche; Y Louagie; P Eucher; B Marchandise; E Rombaut; D Blommaert; E Schroeder
Journal:  Heart       Date:  1999-09       Impact factor: 5.994

4.  [Noninvasive determination of coronary flow reserve with signal enhanced high resolution transthoracic Doppler color echocardiography].

Authors:  H Lambertz; J Bönhof; J Brechtken; T Stein; H P Tries; H Lethen
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

5.  Estimation of coronary flow reserve: can SPECT compete with other modalities?

Authors:  G T Gullberg; E V Di Bella; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

Review 6.  Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler.

Authors:  David E Newby; Keith A A Fox
Journal:  Br J Clin Pharmacol       Date:  2002-06       Impact factor: 4.335

7.  Can coronary flow velocity reserve determined by transthoracic Doppler echocardiography predict the recovery of regional left ventricular function in patients with acute myocardial infarction?

Authors:  Y Ueno; Y Nakamura; M Kinoshita; T Fujita; T Sakamoto; H Okamura
Journal:  Heart       Date:  2002-08       Impact factor: 5.994

8.  Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire.

Authors:  Haruhiko Machida; Yoshiaki Komori; Eiko Ueno; Yun Shen; Masami Hirata; Shinya Kojima; Munekuni Sato; Takeshi Okazaki; Ai Masukawa; Satoru Morita; Kazufumi Suzuki
Journal:  Jpn J Radiol       Date:  2010-10-24       Impact factor: 2.374

9.  Obstructive sleep apnea leads to transient uncoupling of coronary blood flow and myocardial work in humans.

Authors:  Garun S Hamilton; Ian T Meredith; Adrian M Walker; Peter Solin
Journal:  Sleep       Date:  2009-02       Impact factor: 5.849

10.  Accelerated coronary plaque progression and endothelial dysfunction: serial volumetric evaluation by IVUS.

Authors:  Mario Gössl; Myeong-Ho Yoon; Byoung-Jwoo Choi; Charanjit Rihal; Jonella M Tilford; Martin Reriani; Rajiv Gulati; Guri Sandhu; Erik Eeckhout; Ryan Lennon; Lilach O Lerman; Amir Lerman
Journal:  JACC Cardiovasc Imaging       Date:  2014-01
View more