Catheter obstruction effect on pulsatile flow rate--pressure drop during coronary angioplasty.

R K Banerjee1, L H Back, M R Back, Y I Cho.   

Abstract

The coupling of computational hemodynamics to measured translesional mean pressure gradients with an angioplasty catheter in human coronary stenoses was evaluated. A narrowed flow cross section with the catheter present effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angioplasty; thus elevating the pressure gradient and reducing blood flow during the measurements. For resting conditions with the catheter present, flow was believed to be about 40 percent of normal basal flow in the absence of the catheter, and for hyperemia, about 20 percent of elevated flow in the patient group. The computations indicated that the velocity field was viscous dominated and quasi-steady with negligible phase lag in the delta p(t)-u(t) relation during the cardiac cycle at the lower hydraulic Reynolds numbers and frequency parameter. Hemodynamic interactions with smaller catheter-based pressure sensors evolving in clinical use require subsequent study since artifactually elevated translesional pressure gradients can occur during measurements with current angioplasty catheters.

Entities:  

Mesh:

Year:  1999        PMID: 10396693     DOI: 10.1115/1.2798321

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  4 in total

1.  Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model.

Authors:  Srikara Viswanath Peelukhana; Kranthi K Kolli; Massoud A Leesar; Mohamed A Effat; Tarek A Helmy; Imran Arif; Eric W Schneeberger; Paul Succop; Rupak K Banerjee
Journal:  Heart Vessels       Date:  2013-04-30       Impact factor: 2.037

2.  Optimization of intravascular shear stress assessment in vivo.

Authors:  Lisong Ai; Hongyu Yu; Wakako Takabe; Anna Paraboschi; Fei Yu; E S Kim; Rongsong Li; Tzung K Hsiai
Journal:  J Biomech       Date:  2009-05-19       Impact factor: 2.712

3.  Real-time intravascular shear stress in the rabbit abdominal aorta.

Authors:  Lisong Ai; Hongyu Yu; Wangde Dai; Sharon L Hale; Robert A Kloner; Tzung K Hsiai
Journal:  IEEE Trans Biomed Eng       Date:  2009-06       Impact factor: 4.538

4.  Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography.

Authors:  Muneo Kurokawa; Shiro Uemura; Makoto Watanabe; Yoko Dote; Yu Sugawara; Yutaka Goryo; Tomoya Ueda; Satoshi Okayama; Michinori Kayashima; Yoshihiko Saito
Journal:  Int J Cardiol Heart Vasc       Date:  2015-06-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.