Literature DB >> 9129618

Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis.

M Lei1, J P Archie, C Kleinstreuer.   

Abstract

PURPOSE: Recent experimental and theoretic studies show that large wall shear stress gradients characterize disturbed flow patterns associated with the location of myointimal hyperplasia, atheroma, or both. Graft-to-artery anastomoses that minimize wall shear stress gradients may reduce the degree of myointimal development and the propensity for thrombosis. This study analyzes the distribution of distal anastomotic wall shear stress gradients for conventional geometries and for the optimized geometry assuming idealized merging of the graft with the artery.
METHODS: A validated computational fluid dynamics program was used to solve the transient three-dimensional partial differential equations and auxiliary equations that describe laminar incompressible blood flow. Time-averaged wall shear stresses and wall shear stress gradients were calculated for three distal graft-artery anastomoses: a standard end-to-side, a Taylor patch, and an optimized geometry. The latter was obtained iteratively by minimizing the local wall shear stress gradients and was analyzed under resting and exercise inflow waveforms.
RESULTS: Both the standard and Taylor patch anastomoses have relatively high wall shear stress gradients in the regions of the toe and heel. For all flow inputs studied nonuniform hemodynamics in the optimized graft design are largely eliminated, and the time-averaged wall shear stress gradients are greatly reduced throughout the anastomotic zone. At resting flow the Taylor patch produces slightly lower wall shear stress gradients in the anastomotic region than the standard end-to-side anastomosis. The optimized design reduces wall shear stress gradients to almost one half of that of the standard and Taylor patch geometries. At exercise flow wall shear stress gradients almost triple in the standard anastomosis and increase approximately 30% in the Taylor patch. In contrast, the geometrically optimized design is basically independent of the type of flow input waveform in terms of time-averaged wall shear stress gradients and disturbed flow patterns.
CONCLUSION: This study demonstrates that it is possible to design a terminal graft geometry for an end-to-side anastomosis that significantly reduces wall shear stress gradients. If the wall shear stress gradient is confirmed to be a major hemodynamic determinant of intimal hyperplasia and restenosis, these results may point to the design of optimal bypass graft geometries.

Entities:  

Mesh:

Year:  1997        PMID: 9129618     DOI: 10.1016/s0741-5214(97)70289-1

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  16 in total

1.  Patient-specific multiscale modeling of blood flow for coronary artery bypass graft surgery.

Authors:  Sethuraman Sankaran; Mahdi Esmaily Moghadam; Andrew M Kahn; Elaine E Tseng; Julius M Guccione; Alison L Marsden
Journal:  Ann Biomed Eng       Date:  2012-04-27       Impact factor: 3.934

2.  Long-term outcome of a cuffed expanded PTFE graft for hemodialysis vascular access.

Authors:  George Tsoulfas; Martin Hertl; Dicken S C Ko; Nahel Elias; Francis L Delmonico; Linda Romano; Isabel Fernandes; David Schoenfeld; Tatsuo Kawai
Journal:  World J Surg       Date:  2008-08       Impact factor: 3.352

Review 3.  Coronary CT angiography: Beyond morphological stenosis analysis.

Authors:  Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

4.  Why Patencies of Femoropopliteal Bypass Grafts with Distal End-to-End Anastomosis are Comparable with End-to-Side Anastomosis.

Authors:  Marco Hoedt; Thien How; Paul Poyck; Cees Wittens
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-01-26       Impact factor: 1.520

5.  Computer-Aided Patient-Specific Coronary Artery Graft Design Improvements Using CFD Coupled Shape Optimizer.

Authors:  Onur Dur; Sinan Tolga Coskun; Kasim Oguz Coskun; David Frakes; Levent Burak Kara; Kerem Pekkan
Journal:  Cardiovasc Eng Technol       Date:  2010-11-18       Impact factor: 2.495

6.  Evaluation of the hemodynamics in straight 6-mm and tapered 6- to 8-mm grafts as upper arm hemodialysis vascular access.

Authors:  M Sarmast; H Niroomand-Oscuii; F Ghalichi; E Samiei
Journal:  Med Biol Eng Comput       Date:  2014-08-12       Impact factor: 2.602

7.  Longer coronary anastomosis provides lower energy loss in coronary artery bypass grafting.

Authors:  Hiroyuki Tsukui; Manabu Shinke; Young Kwang Park; Kenji Yamazaki
Journal:  Heart Vessels       Date:  2016-08-02       Impact factor: 2.037

8.  A longitudinal study of remodeling in a revised peripheral artery bypass graft using 3D ultrasound imaging and computational hemodynamics.

Authors:  Patrick M McGah; Daniel F Leotta; Kirk W Beach; James J Riley; Alberto Aliseda
Journal:  J Biomech Eng       Date:  2011-04       Impact factor: 2.097

9.  Hemodynamic conditions in a failing peripheral artery bypass graft.

Authors:  Patrick M McGah; Daniel F Leotta; Kirk W Beach; R Eugene Zierler; James J Riley; Alberto Aliseda
Journal:  J Vasc Surg       Date:  2012-05-01       Impact factor: 4.268

10.  Optimization of intravascular shear stress assessment in vivo.

Authors:  Lisong Ai; Hongyu Yu; Wakako Takabe; Anna Paraboschi; Fei Yu; E S Kim; Rongsong Li; Tzung K Hsiai
Journal:  J Biomech       Date:  2009-05-19       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.