Literature DB >> 16488224

Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis.

Abhijit Sinha Roy1, Lloyd H Back, Rupak K Banerjee.   

Abstract

To evaluate the local hemodynamic effects of coronary artery balloon angioplasty, computational fluid dynamics was applied to representative stenoses geometry post-angioplasty (minimal lesion diameter d(m) = 1.8mm which produced 64% mean area stenoses) based on a group of patients and measured values of coronary flow reserve (CFR) returning to a normal range (3.6+/-0.3). The computations were at mean flow rates (Q) of 50, 100, 150 and 170 ml/min. The study indicates changes in the hemodynamic conditions due to insertion of a guidewire, which can be used to determine the mean pressure drop (Deltap ) and fall in distal mean coronary pressure (p(r)), and thus give quantitative estimate of uncertainty expected in diagnosis of moderate lesions. The guidewire to minimal lesion diameter ratio is 0.26, causing tighter "artifactual" mean area stenoses of 65.5%. During hyperemia, p(m) dropped to 72 mmHg as compared to 75 mmHg under patho-physiological condition without guidewire. Q(h) (subscript h: hyperemia) decreased from 180 without guidewire to 170 ml/min with the guidewire present. Thus, there was a significant approximately 43% increase in Deltap(h) and a approximately 51% increase in the hyperemic flow resistance (R(h) = Deltap(h)/Q(h)) over the patho-physiological condition. This could cause an overestimation of the severity of the moderate stenoses. Transient and steady flow guidewire surface shear stress was 35-50% higher than corresponding values for arterial wall shear stress. The non-dimensional data given in tabular form may be useful in interpretation of clinical guidewire measurements for moderate lesions of similar geometry and size.

Entities:  

Mesh:

Year:  2006        PMID: 16488224     DOI: 10.1016/j.jbiomech.2005.01.020

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

Review 1.  Theoretical models for coronary vascular biomechanics: progress & challenges.

Authors:  Sarah L Waters; Jordi Alastruey; Daniel A Beard; Peter H M Bovendeerd; Peter F Davies; Girija Jayaraman; Oliver E Jensen; Jack Lee; Kim H Parker; Aleksander S Popel; Timothy W Secomb; Maria Siebes; Spencer J Sherwin; Rebecca J Shipley; Nicolas P Smith; Frans N van de Vosse
Journal:  Prog Biophys Mol Biol       Date:  2010-10-30       Impact factor: 3.667

Review 2.  Combined functional and anatomical diagnostic endpoints for assessing arteriovenous fistula dysfunction.

Authors:  Ehsan Rajabi-Jaghargh; Rupak K Banerjee
Journal:  World J Nephrol       Date:  2015-02-06

3.  Optimization of intravascular shear stress assessment in vivo.

Authors:  Lisong Ai; Hongyu Yu; Wakako Takabe; Anna Paraboschi; Fei Yu; E S Kim; Rongsong Li; Tzung K Hsiai
Journal:  J Biomech       Date:  2009-05-19       Impact factor: 2.712

4.  Real-time intravascular shear stress in the rabbit abdominal aorta.

Authors:  Lisong Ai; Hongyu Yu; Wangde Dai; Sharon L Hale; Robert A Kloner; Tzung K Hsiai
Journal:  IEEE Trans Biomed Eng       Date:  2009-06       Impact factor: 4.538

5.  Effect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: an analytical approach.

Authors:  Ehsan Rajabi-Jaghargh; Kranthi K Kolli; Lloyd H Back; Rupak K Banerjee
Journal:  Biomed Eng Online       Date:  2011-06-10       Impact factor: 2.819

6.  Simulation of haemodynamic flow in head and neck cancer chemotherapy.

Authors:  Stephan Rhode; Manosh C Paul; Eckhard Martens; Duncan F Campbell
Journal:  Biomed Eng Online       Date:  2011-12-02       Impact factor: 2.819

7.  Numerical investigation of the effect of stenosis geometry on the coronary diagnostic parameters.

Authors:  Sarfaraz Kamangar; Govindaraju Kalimuthu; Irfan Anjum Badruddin; A Badarudin; N J Salman Ahmed; T M Yunus Khan
Journal:  ScientificWorldJournal       Date:  2014-09-01

8.  Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model.

Authors:  Hong-Yang Wang; Long-Shan Liu; Hai-Ming Cao; Jun Li; Rong-Hai Deng; Qian Fu; Huan-Xi Zhang; Ji-Guang Fei; Chang-Xi Wang
Journal:  Chin Med J (Engl)       Date:  2017 5th Jan 2017       Impact factor: 2.628

9.  Effect of guidewire insertion in fractional flow reserve procedure for real geometry using computational fluid dynamics.

Authors:  Yasser Abuouf; Muhamed AlBadawi; Shinichi Ookawara; Mahmoud Ahmed
Journal:  Biomed Eng Online       Date:  2021-09-28       Impact factor: 2.819

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.