Literature DB >> 7799630

The effect of wall distensibility on flow in a two-dimensional end-to-side anastomosis.

D A Steinman1, C R Ethier.   

Abstract

The development of intimal hyperplasia at the distal anastomosis is the major cause of long-term bypass graft failure. To evaluate the suspected role of hemodynamic factors in the pathogenesis of distal intimal hyperplasia, an understanding of anastomotic flow patterns is essential. Due to the complexity of arterial flow, model studies typically make simplifying assumptions, such as treating the artery and graft walls as rigid. In the present study this restriction is relaxed to consider the effects of vessel wall distensibility on anastomotic flow patterns. Flow was simulated in an idealized 2-D distensible end-to-side anastomosis model, using parameters appropriate for the distal circulation and assuming a purely elastic artery wall. A novel numerical approach was developed in which the wall velocities are solved simultaneously with the fluid and pressure fields, while the wall displacements are treated via an iterative update. Both the rigid and distensible cases indicated the presence of elevated temporal variations and low average magnitudes of wall shear stress at sites known to be susceptible to the development of intimal hyperplasia. At these same sites, large spatial gradients of wall shear stress were also noted. Comparison between distensible-walled and corresponding rigid-walled simulations showed moderate changes in wall shear stress at isolated locations, primarily the bed, toe and heel. For example, in the case of a distensible geometry and a physiologic pressure waveform, the heel experienced a 38 percent increase in cycle-averaged shear stress, with a corresponding 15 percent reduction in shear stress variability, both relative to the corresponding values in the rigid-walled case.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7799630     DOI: 10.1115/1.2895733

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  6 in total

Review 1.  Coronary CT angiography: Beyond morphological stenosis analysis.

Authors:  Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

2.  Experimental study of hemodynamics in the Circle of Willis.

Authors:  Guangyu Zhu; Qi Yuan; Jian Yang; Joon Yeo
Journal:  Biomed Eng Online       Date:  2015-01-09       Impact factor: 2.819

3.  Cyclic strain upregulates nitric oxide synthase in cultured bovine aortic endothelial cells.

Authors:  M A Awolesi; W C Sessa; B E Sumpio
Journal:  J Clin Invest       Date:  1995-09       Impact factor: 14.808

4.  Optimization of intravascular shear stress assessment in vivo.

Authors:  Lisong Ai; Hongyu Yu; Wakako Takabe; Anna Paraboschi; Fei Yu; E S Kim; Rongsong Li; Tzung K Hsiai
Journal:  J Biomech       Date:  2009-05-19       Impact factor: 2.712

Review 5.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

6.  The Tissue-Engineered Vascular Graft-Past, Present, and Future.

Authors:  Samand Pashneh-Tala; Sheila MacNeil; Frederik Claeyssens
Journal:  Tissue Eng Part B Rev       Date:  2015-10-08       Impact factor: 6.389

  6 in total