Cardiac index value measurement by invasive, semi-invasive and non invasive techniques: a prospective study in postoperative off pump coronary artery bypass surgery patients.

Murali Chakravarthy1, Subramanyam Rajeev, Vivek Jawali.   

Abstract

The authors prospectively compared three techniques of continuous cardiac index measurements. They were, invasive Continuous Cardiac Index using thermodilution flow-directed Swan-Ganz pulmonary artery catheters, semi invasive Flotrac-arterial pressure derived cardiac index and the non invasive cardiac index measurement-body impedance plethsmography. The cardiac index measurements were made simultaneously in the postoperative period in 20 patients who underwent elective uncomplicated off pump coronary artery bypass graft. The values were collected once in 5 min over a period of 30-40 min. A set of 140 values were obtained from the cohorts in our study. Inter-changeability of the values of cardiac index was analysed using Bland-Altman and mountain plots. The cardiac index values ranged from 1.6 to 3.6 l/min/m(2). The values obtained were interchangeable. The bias and precision respectively were 0.02 and +/-0.06 for continuous cardiac index and Flotrac, 0.18 and +/-0.08 for Flotrac and body impedance plethysmography and 0.16 and +/-0.08 for continuous cardiac index and body impedance plethysmography. Flotrac appears to be more useful during off pump coronary artery bypass surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19412657     DOI: 10.1007/s10877-009-9179-7

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  18 in total

1.  Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheter.

Authors:  Nuan-Yen Su; Chun-Jen Huang; Peishan Tsai; Yung-Wei Hsu; Yu-Chun Hung; Ching-Rong Cheng
Journal:  Acta Anaesthesiol Sin       Date:  2002-09

2.  Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery.

Authors:  J Mayer; J Boldt; T Schöllhorn; K D Röhm; A M Mengistu; S Suttner
Journal:  Br J Anaesth       Date:  2007-01-11       Impact factor: 9.166

3.  Comparison of simultaneous estimation of cardiac output by four techniques in patients undergoing off-pump coronary artery bypass surgery--a prospective observational study.

Authors:  Murali Chakravarthy; T A Patil; K Jayaprakash; Praveen Kalligudd; Dattatreya Prabhakumar; Vivek Jawali
Journal:  Ann Card Anaesth       Date:  2007-07

Review 4.  Pro: Is the pulmonary artery catheter dead?

Authors:  James Ramsay
Journal:  J Cardiothorac Vasc Anesth       Date:  2007-02       Impact factor: 2.628

5.  Cardiac output--have we found the 'gold standard'?

Authors:  Murali Chakravarthy
Journal:  Ann Card Anaesth       Date:  2008 Jan-Jun

6.  [Comparison between continuous and intermittent thermodilution measurement of cardiac output during coronary artery bypass operation].

Authors:  K Schulz; H H Abel; P Werning
Journal:  Anasthesiol Intensivmed Notfallmed Schmerzther       Date:  1997-04       Impact factor: 0.698

7.  Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery.

Authors:  Torsten Bossert; Jan F Gummert; Hartmuth B Bittner; Markus Barten; Thomas Walther; Volkmar Falk; Friedrich W Mohr
Journal:  J Card Surg       Date:  2006 May-Jun       Impact factor: 1.620

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 9.  Pulmonary artery catheters: state of the controversy.

Authors:  Susan K Frazier; Glenda J Skinner
Journal:  J Cardiovasc Nurs       Date:  2008 Mar-Apr       Impact factor: 2.083

10.  Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.

Authors:  Gerard R Manecke; William R Auger
Journal:  J Cardiothorac Vasc Anesth       Date:  2006-10-24       Impact factor: 2.628

View more
  3 in total

1.  The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function.

Authors:  Youn Yi Jo; Jong Wook Song; Young Chul Yoo; Ji Young Park; Jae Kwang Shim; Young Lan Kwak
Journal:  Korean J Anesthesiol       Date:  2011-04-26

2.  Noninvasive cardiac output measurement in clinical practice - From machines to mobiles.

Authors:  Murali Chakravarthy
Journal:  Indian J Anaesth       Date:  2018-08

3.  Non-invasive cardiac output measurement with electrical velocimetry in patients undergoing liver transplantation: comparison of an invasive method with pulmonary thermodilution.

Authors:  De-Jie Wang; I-Shan Lee; An-Hsun Chou; Chun-Yu Chen; Pei-Chi Ting; Yun-Hui Teng; Jr-Rung Lin; Hsin-I Tsai
Journal:  BMC Anesthesiol       Date:  2018-10-02       Impact factor: 2.217

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.