C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation.

Joseph Zambelli1, Tingliang Zhuang, Brian E Nett, Cyril Riddell, Barry Belanger, Guang-Hong Chen.   

Abstract

The current x-ray source trajectory for C-arm based cone-beam CT is a single arc. Reconstruction from data acquired with this trajectory yields cone-beam artifacts for regions other than the central slice. In this work we present the preliminary evaluation of reconstruction from a source trajectory of two concentric arcs using a flat-panel detector equipped C-arm gantry (GE Healthcare Innova 4100 system, Waukesha, Wisconsin). The reconstruction method employed is a summation of FDK-type reconstructions from the two individual arcs. For the angle between arcs studied here, 30°, this method offers a significant reduction in the visibility of cone-beam artifacts, with the additional advantages of simplicity and ease of implementation due to the fact that it is a direct extension of the reconstruction method currently implemented on commercial systems. Reconstructed images from data acquired from the two arc trajectory are compared to those reconstructed from a single arc trajectory and evaluated in terms of spatial resolution, low contrast resolution, noise, and artifact level.

Year:  2008        PMID: 19381355      PMCID: PMC2670100          DOI: 10.1117/12.772781

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  11 in total

1.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

Authors:  D A Jaffray; J H Siewerdsen
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

2.  Dedicated breast CT: radiation dose and image quality evaluation.

Authors:  J M Boone; T R Nelson; K K Lindfors; J A Seibert
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

3.  Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery.

Authors:  J H Siewerdsen; D J Moseley; S Burch; S K Bisland; A Bogaards; B C Wilson; D A Jaffray
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

4.  Dose and image quality for a cone-beam C-arm CT system.

Authors:  Rebecca Fahrig; Robert Dixon; Thomas Payne; Richard L Morin; Arundhuti Ganguly; Norbert Strobel
Journal:  Med Phys       Date:  2006-12       Impact factor: 4.071

5.  Computed tomography scanning with simultaneous patient translation.

Authors:  C R Crawford; K F King
Journal:  Med Phys       Date:  1990 Nov-Dec       Impact factor: 4.071

6.  Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results.

Authors:  R Fahrig; A J Fox; S Lownie; D W Holdsworth
Journal:  AJNR Am J Neuroradiol       Date:  1997-09       Impact factor: 3.825

7.  Measurement of the PSF for a CT scanner: appropriate wire diameter and pixel size.

Authors:  E L Nickoloff
Journal:  Phys Med Biol       Date:  1988-01       Impact factor: 3.609

8.  Cone-beam volume CT breast imaging: feasibility study.

Authors:  Biao Chen; Ruola Ning
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

9.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

10.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT.

Authors:  J H Siewerdsen; M J Daly; B Bakhtiar; D J Moseley; S Richard; H Keller; D A Jaffray
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

View more
  1 in total

1.  Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

Authors:  Stephen Brunner; Brian E Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2011-01-21       Impact factor: 3.609

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.