Literature DB >> 19365850

Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

Tolga Cukur1, Jin H Lee, Neal K Bangerter, Brian A Hargreaves, Dwight G Nishimura.   

Abstract

Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat signal, robust fat suppression is essential for detailed depiction of the vasculature. Therefore, several strategies have been investigated to improve the reliability of fat suppression within short scan times. Phase-sensitive SSFP can efficiently suppress fat; however, partial volume effects due to fat and water occupying the same voxel can lead to the loss of blood signal. In contrast, alternating repetition time (ATR) SSFP minimizes this loss; however, the level of suppression is compromised by field inhomogeneity. Finally, a new double-acquisition ATR-SSFP technique reduces this sensitivity to off-resonance. In vivo results indicate that the two ATR-based techniques provide more reliable contrast when partial volume effects are significant.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19365850      PMCID: PMC2760085          DOI: 10.1002/mrm.21921

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Linear combination steady-state free precession MRI.

Authors:  S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

3.  Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.

Authors:  K Scheffler; O Heid; J Hennig
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

4.  Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

Authors:  Brian A Hargreaves; Neal K Bangerter; Ann Shimakawa; Shreyas S Vasanawala; Jean H Brittain; Dwight G Nishimura
Journal:  Magn Reson Imaging       Date:  2006-01-10       Impact factor: 2.546

5.  Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Authors:  Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

6.  3D non-contrast-enhanced MR angiography with balanced steady-state free precession Dixon method.

Authors:  Randall B Stafford; Mohammad Sabati; Houman Mahallati; Richard Frayne
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

7.  Oxygen-sensitive contrast in blood for steady-state free precession imaging.

Authors:  Rohan Dharmakumar; Juimiin Hong; Jean H Brittain; Donald B Plewes; Graham A Wright
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

8.  Nephrogenic systemic fibrosis: suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging.

Authors:  Peter Marckmann; Lone Skov; Kristian Rossen; Anders Dupont; Mette Brimnes Damholt; James Goya Heaf; Henrik S Thomsen
Journal:  J Am Soc Nephrol       Date:  2006-08-02       Impact factor: 10.121

9.  Fat-water separation with alternating repetition time balanced SSFP.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

10.  Joint estimation of water/fat images and field inhomogeneity map.

Authors:  D Hernando; J P Haldar; B P Sutton; J Ma; P Kellman; Z-P Liang
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

View more
  17 in total

1.  Noncontrast peripheral MRA with spiral echo train imaging.

Authors:  Samuel W Fielden; John P Mugler; Klaus D Hagspiel; Patrick T Norton; Christopher M Kramer; Craig H Meyer
Journal:  Magn Reson Med       Date:  2014-04-17       Impact factor: 4.668

2.  Non-Contrast Renal MR Angiography: Value of Subtraction of Tagging and Non-Tagging Technique.

Authors:  Takehiro Shimada; Makoto Amanuma; Ayako Takahashi; Yoshito Tsushima
Journal:  Ann Vasc Dis       Date:  2012

Review 3.  Considerations for Imaging the Inferior Vena Cava (IVC) with/without IVC Filters.

Authors:  Jessie Aw-Zoretic; Jeremy D Collins
Journal:  Semin Intervent Radiol       Date:  2016-06       Impact factor: 1.513

4.  Three-dimensional fluid-suppressed T2-prep flow-independent peripheral angiography using balanced SSFP.

Authors:  Neal K Bangerter; Tolga Cukur; Brian A Hargreaves; Bob S Hu; Jean H Brittain; Danny Park; Garry E Gold; Dwight G Nishimura
Journal:  Magn Reson Imaging       Date:  2011-06-25       Impact factor: 2.546

5.  Magnetization-prepared IDEAL bSSFP: a flow-independent technique for noncontrast-enhanced peripheral angiography.

Authors:  Tolga Cukur; Ann Shimakawa; Huanzhou Yu; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

6.  Simultaneous fat suppression and band reduction with large-angle multiple-acquisition balanced steady-state free precession.

Authors:  Brady Quist; Brian A Hargreaves; Tolga Cukur; Glen R Morrell; Garry E Gold; Neal K Bangerter
Journal:  Magn Reson Med       Date:  2011-10-28       Impact factor: 4.668

7.  Refocused turbo spin-echo for noncontrast peripheral MR angiography.

Authors:  Samuel W Fielden; John P Mugler; Klaus D Hagspiel; Patrick T Norton; Christopher M Kramer; Craig H Meyer
Journal:  J Magn Reson Imaging       Date:  2013-09-04       Impact factor: 4.813

8.  Signal compensation and compressed sensing for magnetization-prepared MR angiography.

Authors:  Tolga Çukur; Michael Lustig; Emine U Saritas; Dwight G Nishimura
Journal:  IEEE Trans Med Imaging       Date:  2011-02-17       Impact factor: 10.048

9.  High-resolution 3D radial bSSFP with IDEAL.

Authors:  Catherine J Moran; Ethan K Brodsky; Leah Henze Bancroft; Scott B Reeder; Huanzhou Yu; Richard Kijowski; Dorothee Engel; Walter F Block
Journal:  Magn Reson Med       Date:  2013-03-15       Impact factor: 4.668

10.  "Push-button" noncontrast MR angiography using balanced T1 relaxation-enhanced steady-state (bT1RESS).

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2020-09-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.