Literature DB >> 22038883

Simultaneous fat suppression and band reduction with large-angle multiple-acquisition balanced steady-state free precession.

Brady Quist1, Brian A Hargreaves, Tolga Cukur, Glen R Morrell, Garry E Gold, Neal K Bangerter.   

Abstract

Balanced steady-state free precession (bSSFP) MRI is a rapid and signal-to-noise ratio-efficient imaging method, but suffers from characteristic bands of signal loss in regions of large field inhomogeneity. Several methods have been developed to reduce the severity of these banding artifacts, typically involving the acquisition of multiple bSSFP datasets (and the accompanying increase in scan time). Fat suppression with bSSFP is also challenging; most existing methods require an additional increase in scan time, and some are incompatible with bSSFP band-reduction techniques. This work was motivated by the need for both robust fat suppression and band reduction in the presence of field inhomogeneity when using bSSFP for flow-independent peripheral angiography. The large flip angles used in this application to improve vessel conspicuity and contrast lead to specific absorption rate considerations, longer repetition times, and increased severity of banding artifacts. In this work, a novel method that simultaneously suppresses fat and reduces bSSFP banding artifact with the acquisition of only two phase-cycled bSSFP datasets is presented. A weighted sum of the two bSSFP acquisitions is taken on a voxel-by-voxel basis, effectively synthesizing an off-resonance profile at each voxel that puts fat in the stop band while keeping water in the pass band. The technique exploits the near-sinusoidal shape of the bSSFP off-resonance spectrum for many tissues at large (>50°) flip angles.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22038883      PMCID: PMC3306491          DOI: 10.1002/mrm.23076

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Linear combination steady-state free precession MRI.

Authors:  S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  Fluctuating equilibrium MRI.

Authors:  S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.

Authors:  K Scheffler; O Heid; J Hennig
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

4.  Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences.

Authors:  Juergen Hennig; Oliver Speck; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2002-11       Impact factor: 4.668

5.  Fat and water separation in balanced steady-state free precession using the Dixon method.

Authors:  Teng-Yi Huang; Hsiao-Wen Chung; Fu-Nien Wang; Cheng-Wen Ko; Cheng-Yu Chen
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

6.  Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

Authors:  Scott B Reeder; Zhifei Wen; Huanzhou Yu; Angel R Pineda; Garry E Gold; Michael Markl; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

7.  Fat-suppressed steady-state free precession imaging using phase detection.

Authors:  Brian A Hargreaves; Shreyas S Vasanawala; Krishna S Nayak; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

8.  Frequency-modulated steady-state free precession imaging.

Authors:  D L Foxall
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

9.  Wideband SSFP: alternating repetition time balanced steady state free precession with increased band spacing.

Authors:  Krishna S Nayak; Hsu-Lei Lee; Brian A Hargreaves; Bob S Hu
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

10.  Fat-water separation with alternating repetition time balanced SSFP.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more
  3 in total

1.  ISMRM workshop on fat-water separation: insights, applications and progress in MRI.

Authors:  Houchun Harry Hu; Peter Börnert; Diego Hernando; Peter Kellman; Jingfei Ma; Scott Reeder; Claude Sirlin
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

2.  Balanced SSFP Dixon imaging with banding-artifact reduction at 3 Tesla.

Authors:  Brady Quist; Brian A Hargreaves; Bruce L Daniel; Manojkumar Saranathan
Journal:  Magn Reson Med       Date:  2014-09-16       Impact factor: 4.668

3.  Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively.

Authors:  Emeline J Ribot; Didier Wecker; Aurélien J Trotier; Benjamin Dallaudière; William Lefrançois; Eric Thiaudière; Jean-Michel Franconi; Sylvain Miraux
Journal:  PLoS One       Date:  2015-10-01       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.