Literature DB >> 32936486

"Push-button" noncontrast MR angiography using balanced T1 relaxation-enhanced steady-state (bT1RESS).

Robert R Edelman1,2, Ioannis Koktzoglou1,3.   

Abstract

PURPOSE: We introduce a MR imaging technique, balanced T1 relaxation-enhanced steady-state (bT1RESS), that provides the unique capability to efficiently impart a flexible amount of T1 weighting to a balanced steady-state free precession acquisition using periodically applied contrast-modifying RF pulses. Leveraging this capability to suppress the signal intensity of background tissues, we implemented a 3D noncontrast MR angiography technique that continuously acquires thin overlapping 3D volumes and tested it for evaluation of the peripheral arteries.
METHODS: bT1RESS used a fast interrupted steady-state readout with a 45° cslab-selective ontrast-modifying RF pulse applied at 262 msec intervals. A series of 16.4-mm thick overlapping 3D volumes was acquired using a radial stack-of-stars k-space trajectory. The combination of slice oversampling, slab overlap, and averaging of edge slices was helpful to reduce venetian blind artifact. Spatial resolution was near isotropic with reconstructed slice thickness = 0.7 mm and in-plane resolution = 0.5 mm.
RESULTS: Pilot studies in the peripheral arteries demonstrated improved vessel sharpness compared with cardiac-gated quiescent interval slice-selective noncontrast MR angiography. bT1RESS noncontrast MR angiography reliably identified stenotic and occlusive arterial disease in a small cohort of patients with peripheral artery disease.
CONCLUSIONS: bT1RESS provides the basis for a simplified, completely "push button" approach for noncontrast MR angiography that obviates the need for contrast agents, electrocardiographic gating, scout imaging, breath holding, or tailoring of imaging parameters for the individual patient. Further work is needed for technical optimization and clinical validation.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  balanced T1 relaxation-enhanced steady-state (bT1RESS); fast interrupted steady-state (FISS); magnetic resonance (MR); noncontrast MR angiography; stack-of-stars

Mesh:

Year:  2020        PMID: 32936486      PMCID: PMC7718305          DOI: 10.1002/mrm.28492

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  49 in total

1.  Projection reconstruction techniques for reduction of motion effects in MRI.

Authors:  G H Glover; J M Pauly
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

2.  Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA.

Authors:  Gesine Knobloch; Marie-Teres Lauff; Sebastian Hirsch; Carsten Schwenke; Bernd Hamm; Moritz Wagner
Journal:  Eur Radiol       Date:  2016-02-10       Impact factor: 5.315

Review 3.  Steady-state MR imaging sequences: physics, classification, and clinical applications.

Authors:  Govind B Chavhan; Paul S Babyn; Bhavin G Jankharia; Hai-Ling M Cheng; Manohar M Shroff
Journal:  Radiographics       Date:  2008 Jul-Aug       Impact factor: 5.333

Review 4.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

5.  Accuracy of Noncontrast Quiescent-Interval Single-Shot Lower Extremity MR Angiography Versus CT Angiography for Diagnosis of Peripheral Artery Disease: Comparison With Digital Subtraction Angiography.

Authors:  Akos Varga-Szemes; Julian L Wichmann; U Joseph Schoepf; Pal Suranyi; Carlo N De Cecco; Giuseppe Muscogiuri; Damiano Caruso; Ricardo T Yamada; Sheldon E Litwin; Christian Tesche; Taylor M Duguay; Shivraman Giri; Rozemarijn Vliegenthart; Thomas M Todoran
Journal:  JACC Cardiovasc Imaging       Date:  2017-01-18

6.  Evaluation of velocity-sensitized and acceleration-sensitized NCE-MRA for below-knee peripheral arterial disease.

Authors:  Nadeem Shaida; Andrew N Priest; T C See; Andrew P Winterbottom; Martin J Graves; David J Lomas
Journal:  J Magn Reson Imaging       Date:  2016-11-30       Impact factor: 4.813

7.  Evaluation of peripheral arterial disease with nonenhanced quiescent-interval single-shot MR angiography.

Authors:  Philip A Hodnett; Ioannis Koktzoglou; Amir H Davarpanah; Timothy G Scanlon; Jeremy D Collins; John J Sheehan; Eugene E Dunkle; Navyash Gupta; James C Carr; Robert R Edelman
Journal:  Radiology       Date:  2011-04-18       Impact factor: 11.105

8.  Radial fast interrupted steady-state (FISS) magnetic resonance imaging.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

9.  Incidence of nephrogenic systemic fibrosis at two large medical centers.

Authors:  Martin R Prince; Honglei Zhang; Michael Morris; Jennifer L MacGregor; Marc E Grossman; Jeffrey Silberzweig; Robert L DeLapaz; Henry J Lee; Cynthia M Magro; Anthony M Valeri
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

10.  Non-contrast-enhanced MR angiography at 3 Tesla in patients with advanced peripheral arterial occlusive disease.

Authors:  Kolja M Thierfelder; Georgios Meimarakis; Konstantin Nikolaou; Wieland H Sommer; Peter Schmitt; Philipp M Kazmierczak; Maximilian F Reiser; Daniel Theisen
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

View more
  1 in total

1.  Quantitative time-of-flight MR angiography for simultaneous luminal and hemodynamic evaluation of the intracranial arteries.

Authors:  Ioannis Koktzoglou; Rong Huang; Robert R Edelman
Journal:  Magn Reson Med       Date:  2021-08-10       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.