Literature DB >> 19352658

Long-term results of the standard Wagner cup.

Uwe Demmelmeyer1, Annemarie Schraml, Wolfgang Hönle, Alexander Schuh.   

Abstract

Cementless acetabular components gained popularity because of the increased rate of loosening associated with cemented cups after intermediate and long-term follow-up. There are few long-term follow-up studies of cementless acetabular components. This study aims to evaluate the clinical and radiological long-term results of the press-fit standard Wagner Cup. Between January 1, 1994 and June 30, 1994, 118 implantations of a standard Wagner Cup were performed, and 102 implants were clinically and radiographically followed-up after a mean of 12.0 years. The Merle d'Aubigné score improved from a preoperative mean of 9.5 to 17.2 at latest follow-up. Early postoperative complications included two deep haematomata requiring needle aspiration, two deep vein thromboses, one pulmonary embolism, two temporary lesions of the sciatic nerve, one single event of THR dislocation and one recurrent dislocation. Two isolated cup revisions and five more complete total hip replacements were performed for aseptic loosening. The overall survival rate at 12 years was 93.1% (95/102). The standard Wagner cup yields very good long-term results.

Entities:  

Mesh:

Year:  2009        PMID: 19352658      PMCID: PMC2899267          DOI: 10.1007/s00264-009-0766-5

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  18 in total

Review 1.  What's new in hip arthroplasty.

Authors:  Michael H Huo
Journal:  J Bone Joint Surg Am       Date:  2002-10       Impact factor: 5.284

2.  Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation.

Authors:  Charles A Engh; Robert H Hopper; C Anderson Engh
Journal:  J Arthroplasty       Date:  2004-10       Impact factor: 4.757

3.  Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations.

Authors:  M Jasty; D D Goetz; C R Bragdon; K R Lee; A E Hanson; J R Elder; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1997-03       Impact factor: 5.284

4.  Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years.

Authors:  James D Crowther; Paul F Lachiewicz
Journal:  J Bone Joint Surg Am       Date:  2002-05       Impact factor: 5.284

5.  Patterns of osteolysis around total hip components inserted with and without cement.

Authors:  B Zicat; C A Engh; E Gokcen
Journal:  J Bone Joint Surg Am       Date:  1995-03       Impact factor: 5.284

6.  Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty.

Authors:  Anthony M Young; Christi J Sychterz; Robert H Hopper; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2002-01       Impact factor: 5.284

7.  Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty.

Authors:  C A Engh; W J Culpepper; C A Engh
Journal:  J Bone Joint Surg Am       Date:  1997-02       Impact factor: 5.284

8.  Second-generation cementless total hip arthroplasty. Eight to eleven-year results.

Authors:  M J Archibeck; R A Berger; J J Jacobs; L R Quigley; S Gitelis; A G Rosenberg; J O Galante
Journal:  J Bone Joint Surg Am       Date:  2001-11       Impact factor: 5.284

9.  Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty.

Authors:  Alejandro González Della Valle; Adriana Zoppi; Margaret G E Peterson; Eduardo A Salvati
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

10.  The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

Authors:  R C Russell; A Ghassemi; J H Dorrell; D P Powles
Journal:  Int Orthop       Date:  2008-06-13       Impact factor: 3.075

View more
  2 in total

1.  Mid-term clinical results of total hip arthroplasty using a Wagner standard cup for dysplastic hip.

Authors:  Katsuhiko Maezawa; Masahiko Nozawa; Takahito Yuasa; Kentaro Aritomi; Seiki Ogawa; Yuichiro Maruyama; Kazuo Kaneko
Journal:  J Orthop       Date:  2014-09-06

2.  Excessive polyethylene wear and acetabular bone defects from standard use of a hooded acetabular insert in total hip arthroplasty.

Authors:  Davey M J M Gerhardt; Rick J M Sanders; Enrico de Visser; Job L C van Susante
Journal:  Int Orthop       Date:  2014-04-04       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.