Literature DB >> 11701789

Second-generation cementless total hip arthroplasty. Eight to eleven-year results.

M J Archibeck1, R A Berger, J J Jacobs, L R Quigley, S Gitelis, A G Rosenberg, J O Galante.   

Abstract

BACKGROUND: Second-generation cementless femoral components were designed to provide more reliable ingrowth and to limit distal osteolysis by incorporating circumferential proximal ingrowth surfaces. We examined the eight to eleven-year results of total hip arthroplasty with a cementless, anatomically designed femoral component and a cementless hemispheric acetabular component.
METHODS: Ninety-two consecutive primary total hip arthroplasties with implantation of a femoral component with a circumferential proximal porous coating (Anatomic Hip) and a cementless hemispheric porous-coated acetabular component (Harris-Galante II) were performed in eighty-five patients. These patients were prospectively followed clinically and radiographically. Six patients (seven hips) died and five patients (seven hips) were lost to follow-up, leaving seventy-four patients (seventy-eight hips) who had been followed for a mean of ten years (range, eight to eleven years). The mean age at the time of the arthroplasty was fifty-two years.
RESULTS: The mean preoperative Harris hip score of 51 points improved to 94 points at the time of final follow-up; 86% of the hips had a good or excellent result. Thigh pain was reported as mild to severe after seven hip arthroplasties. No femoral component was revised for any reason, and none were loose radiographically at the time of the last follow-up. Two hips underwent acetabular revision (one because of dislocation and one because of loosening). Kaplan-Meier survivorship analysis was performed with revision or loosening of any component as the end point. The ten-year survival rate was 96.4% +/- 2.1% for the total hip prosthesis, 100% for the femoral component, and 96.4% +/- 2.1% for the acetabular component. Radiolucencies adjacent to the nonporous portion of the femoral component were seen in sixty-eight (93%) of the -seventy-three hips with complete radiographic follow-up. Femoral osteolysis proximal to the lesser trochanter was noted in four hips (5%). No osteolysis was identified distal to the lesser trochanter. Periacetabular osteolysis was identified in twelve hips (16%). Five patients underwent exchange of the acetabular liner because of polyethylene wear.
CONCLUSIONS: This second-generation cementless, anatomically designed femoral component provided excellent clinical and radiographic results with a 100% survival rate at ten years. The circumferential porous coating of this implant improved ingrowth and prevented distal osteolysis at a mean of ten years after the arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11701789     DOI: 10.2106/00004623-200111000-00008

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  25 in total

1.  Fifteen- to 20-year results of uncemented tapered fully porous-coated cobalt-chrome stems.

Authors:  Taek Rim Yoon; Sung-Man Rowe; Myung-Sun Kim; Sang-Gwon Cho; Jong-Keun Seon
Journal:  Int Orthop       Date:  2007-02-24       Impact factor: 3.075

2.  A long-term follow-up study of the cementless THA with anatomic stem/HGPII cup with 22-mm head.

Authors:  Yutaka Nakoshi; Masahiro Hasegawa; Akihiro Sudo; Atsumasa Uchida
Journal:  Int Orthop       Date:  2008-01-09       Impact factor: 3.075

3.  Long-term results of the standard Wagner cup.

Authors:  Uwe Demmelmeyer; Annemarie Schraml; Wolfgang Hönle; Alexander Schuh
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

Review 4.  Osteonecrosis is not a predictor of poor outcomes in primary total hip arthroplasty: a systematic literature review.

Authors:  Henning R Johannson; Michael G Zywiel; David R Marker; Lynne C Jones; Mike S McGrath; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-25       Impact factor: 3.075

5.  Risk factors for early revision after total hip arthroplasty.

Authors:  Christopher J Dy; Kevin J Bozic; Ting Jung Pan; Timothy M Wright; Douglas E Padgett; Stephen Lyman
Journal:  Arthritis Care Res (Hoboken)       Date:  2014-06       Impact factor: 4.794

6.  Is the bone-bonding ability of a cementless total hip prosthesis enhanced by alkaline and heat treatments?

Authors:  Kazutaka So; Ayumi Kaneuji; Tadami Matsumoto; Shuichi Matsuda; Haruhiko Akiyama
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

7.  Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older.

Authors:  Keijo T Mäkelä; Antti Eskelinen; Pekka Paavolainen; Pekka Pulkkinen; Ville Remes
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Survival of Bi-Metric femoral stems in 77 total hip arthroplasties for juvenile chronic arthritis.

Authors:  C C Lybäck; C O Lybäck; A Kyrö; H J Kautiainen; E A Belt
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

9.  Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population.

Authors:  Peteris Studers; Danils Belajevs; Vitolds Jurkevics; Peteris Likums
Journal:  Int Orthop       Date:  2015-07-30       Impact factor: 3.075

10.  [Femoral neck prostheses].

Authors:  C Stukenborg-Colsman
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.