Literature DB >> 9070522

Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations.

M Jasty1, D D Goetz, C R Bragdon, K R Lee, A E Hanson, J R Elder, W H Harris.   

Abstract

We evaluated the rates of volumetric wear and the patterns of wear of 128 acetabular components retrieved during an autopsy or a revision operation between one and twenty-one years after total hip arthroplasty. Twenty-two all-polyethylene components were retrieved at autopsy from hips that had been functioning well at the time of death (Group A). The remaining 106 components--eighty-four all-polyethylene components (Group B) and twenty-two metal-backed components (Group C)--were retrieved during revision operations. All 128 components had been inserted with cement. The mean rate of volumetric wear, determined directly with a fluid-displacement method, was thirty-five cubic millimeters per year (range, eight to 116 cubic millimeters per year) for Group A, sixty-two cubic millimeters per year (range, eight to 256 cubic millimeters per year) for Group B, and ninety-four cubic millimeters per year (range, twelve to 284 cubic millimeters per year) for Group C. Multivariate regression analysis showed a significant relationship (p < 0.05) between the size of the femoral head and the calculated mean annual rate of volumetric wear. The rate of volumetric wear was highest in association with thirty-two-millimeter femoral heads and lowest in association with twenty-two-millimeter heads; according to linear regression analysis, this represented a 7.5 per cent increase (Group A) or a 10 per cent increase (Group B) in the rate of wear for every one-millimeter increase in the size of the head. Linear regression analysis also showed a significant relationship between the duration that the implant had been in situ and the rate of wear (p < 0.05), with the rate being highest initially after the operation and decreasing with an increasing duration in situ. With the numbers available, the patient's age and gender and the side of the arthroplasty did not have a significant relationship to the annual rate of volumetric wear. Increased thickness of the polyethylene was related to a decreased rate of wear (p < 0.05) in the group of metal-backed components, which had a 25 per cent increase in the rate of wear for every one-millimeter decrease in thickness, but not in the other groups. The estimated median annual rates of wear, after adjustment of confounding variables to a hypothetical constant set of median values for the parameters (duration in situ, 132 months; diameter of the femoral head, twenty-six millimeters; and thickness of the polyethylene, eight millimeters), were significantly different among the three groups of components (p < 0.05). Histological evaluation of the worn surfaces showed the predominant mechanisms of wear to be abrasion and adhesion rather than fatigue-cracking or delamination. The highly worn areas were polished to a glassy finish on gross examination, but scanning electron microscopy showed numerous multidirectional scratches along with fine, drawn-out fibrils with a diameter of one micrometer or less oriented parallel to each other. These fibrils are the most likely source of submicrometer wear particles. Thus, wear appeared to occur mostly at the surface of the components and to be due to large-strain plastic deformation and orientation of the surface layers into fibrils that subsequently ruptured during multidirectional motion.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9070522

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  24 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.

Authors:  Ebru Oral; Steven D Christensen; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2006-06       Impact factor: 4.757

3.  Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

Authors:  Hannah J Lundberg; Douglas R Pedersen; Thomas E Baer; Marian Muste; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-02       Impact factor: 2.712

4.  Crystal ageing in irradiated ultra high molecular weight polyethylene.

Authors:  D Barron; M N Collins; M J Flannery; J J Leahy; C Birkinshaw
Journal:  J Mater Sci Mater Med       Date:  2007-12-12       Impact factor: 3.896

5.  Long-term results of the standard Wagner cup.

Authors:  Uwe Demmelmeyer; Annemarie Schraml; Wolfgang Hönle; Alexander Schuh
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

6.  The first 50 years of total hip arthroplasty: lessons learned.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2008-11-04       Impact factor: 4.176

7.  Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface.

Authors:  Anneliese D Heiner; Hannah J Lundberg; Thomas E Baer; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2008-06-17       Impact factor: 2.712

8.  Polyethylene wear is related to patient-specific contact stress in THA.

Authors:  Robert Košak; Veronika Kralj-Iglič; Aleš Iglič; Matej Daniel
Journal:  Clin Orthop Relat Res       Date:  2011-09-24       Impact factor: 4.176

9.  [Total hip replacement in developmental dysplasia: anatomical features and technical pitfalls].

Authors:  B M Holzapfel; D Bürklein; F Greimel; U Nöth; M Hoberg; H Gollwitzer; M Rudert
Journal:  Orthopade       Date:  2011-06       Impact factor: 1.087

10.  Does stem design influence component positioning in total hip arthroplasty using a minimal invasive posterolateral approach?

Authors:  Wenzel Waldstein; Christian Merle; Tom Schmidt-Braekling; Friedrich Boettner
Journal:  Int Orthop       Date:  2014-03-07       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.