Literature DB >> 18551293

The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

R C Russell1, A Ghassemi, J H Dorrell, D P Powles.   

Abstract

The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7-18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance.

Entities:  

Mesh:

Year:  2008        PMID: 18551293      PMCID: PMC2898964          DOI: 10.1007/s00264-008-0592-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  14 in total

1.  Cardiac output during hemiarthroplasty of the hip. A prospective, controlled trial of cemented and uncemented prostheses.

Authors:  D I Clark; A B Ahmed; B R Baxendale; C G Moran
Journal:  J Bone Joint Surg Br       Date:  2001-04

2.  Minimum 10-year results of a tapered cementless hip replacement.

Authors:  D P Sakalkale; K Eng; W J Hozack; R H Rothman
Journal:  Clin Orthop Relat Res       Date:  1999-05       Impact factor: 4.176

3.  Cementless titanium tapered-wedge femoral stem: 10- to 15-year follow-up.

Authors:  Amanda D Marshall; Jeffrey G Mokris; Richard D Reitman; Alicia Dandar; David R Mauerhan
Journal:  J Arthroplasty       Date:  2004-08       Impact factor: 4.757

4.  Alarming wear of the first-generation polyethylene liner of the cementless porous-coated Biomet Universal cup: 107 hips followed for mean 6 years.

Authors:  T J Puolakka; H J Laine; T P Moilanen; A M Koivisto; K J Pajamäki
Journal:  Acta Orthop Scand       Date:  2001-02

5.  Risk factors for intraoperative femoral fractures during total hip replacement.

Authors:  A Moroni; C Faldini; F Piras; S Giannini
Journal:  Ann Chir Gynaecol       Date:  2000

6.  Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use.

Authors:  T H Mallory; W C Head; A V Lombardi; R H Emerson; R W Eberle; M B Mitchell
Journal:  J Arthroplasty       Date:  1996-09       Impact factor: 4.757

7.  Taperloc femoral component. A 2-6-year study of the first 100 consecutive cases.

Authors:  W Hozack; R Gardiner; S Hearn; K Eng; R Rothman
Journal:  J Arthroplasty       Date:  1994-10       Impact factor: 4.757

8.  Polyethylene wear and periprosthetic osteolysis in metal-backed acetabular components with cylindrical liners.

Authors:  R E Perez; J A Rodriguez; R G Deshmukh; C S Ranawat
Journal:  J Arthroplasty       Date:  1998-01       Impact factor: 4.757

9.  Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series.

Authors:  Y H Kim; J S Kim; S H Cho
Journal:  J Arthroplasty       Date:  1999-08       Impact factor: 4.757

10.  Results of the total bi-metric cementless hip arthroplasty.

Authors:  K Robertsen; M Gaarden; G Teichert; O Langhoff
Journal:  Orthopedics       Date:  1996-08       Impact factor: 1.390

View more
  2 in total

1.  Long-term results of the standard Wagner cup.

Authors:  Uwe Demmelmeyer; Annemarie Schraml; Wolfgang Hönle; Alexander Schuh
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

Review 2.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.