Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning.

Steven Babic1, Andrea McNiven, Jerry Battista, Kevin Jordan.   

Abstract

The dosimetry of small fields as used in stereotactic radiotherapy, radiosurgery and intensity-modulated radiation therapy can be challenging and inaccurate due to partial volume averaging effects and possible disruption of charged particle equilibrium. Consequently, there exists a need for an integrating, tissue equivalent dosimeter with high spatial resolution to avoid perturbing the radiation beam and artificially broadening the measured beam penumbra. In this work, radiochromic ferrous xylenol-orange (FX) and leuco crystal violet (LCV) micelle gels were used to measure relative dose factors (RDFs), percent depth dose profiles and relative lateral beam profiles of 6 MV x-ray pencil beams of diameter 28.1, 9.8 and 4.9 mm. The pencil beams were produced via stereotactic collimators mounted on a Varian 2100 EX linear accelerator. The gels were read using optical computed tomography (CT). Data sets were compared quantitatively with dosimetric measurements made with radiographic (Kodak EDR2) and radiochromic (GAFChromic EBT) film, respectively. Using a fast cone-beam optical CT scanner (Vista), corrections for diffusion in the FX gel data yielded RDFs that were comparable to those obtained by minimally diffusing LCV gels. Considering EBT film-measured RDF data as reference, cone-beam CT-scanned LCV gel data, corrected for scattered stray light, were found to be in agreement within 0.5% and -0.6% for the 9.8 and 4.9 mm diameter fields, respectively. The validity of the scattered stray light correction was confirmed by general agreement with RDF data obtained from the same LCV gel read out with a laser CT scanner that is less prone to the acceptance of scattered stray light. Percent depth dose profiles and lateral beam profiles were found to agree within experimental error for the FX gel (corrected for diffusion), LCV gel (corrected for scattered stray light), and EBT and EDR2 films. The results from this study reveal that a three-dimensional dosimetry method utilizing optical CT-scanned radiochromic gels allows for the acquisition of a self-consistent volumetric data set in a single exposure, with sufficient spatial resolution to accurately characterize small fields.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19336848     DOI: 10.1088/0031-9155/54/8/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Commissioning and benchmarking a 3D dosimetry system for clinical use.

Authors:  Andrew Thomas; Joseph Newton; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

3.  Comprehensive quality assurance for base of skull IMRT.

Authors:  A Thomas; J O'Daniel; J Adamovics; G Ibbott; M Oldham
Journal:  J Phys Conf Ser       Date:  2013

4.  A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation.

Authors:  Mark Oldham; Andrew Thomas; Jennifer O'Daniel; Titania Juang; Geoffrey Ibbott; John Adamovics; John P Kirkpatrick
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-02-22       Impact factor: 7.038

5.  A method to correct for stray light in telecentric optical-CT imaging of radiochromic dosimeters.

Authors:  Andrew Thomas; Joseph Newton; Mark Oldham
Journal:  Phys Med Biol       Date:  2011-06-30       Impact factor: 3.609

6.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

7.  Investigating end-to-end accuracy of image guided radiation treatment delivery using a micro-irradiator.

Authors:  L J Rankine; J Newton; S T Bache; S K Das; J Adamovics; D G Kirsch; M Oldham
Journal:  Phys Med Biol       Date:  2013-10-18       Impact factor: 3.609

8.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01

9.  The effect of motion on IMRT - looking at interplay with 3D measurements.

Authors:  A Thomas; H Yan; M Oldham; T Juang; J Adamovics; F F Yin
Journal:  J Phys Conf Ser       Date:  2013

Review 10.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.