Literature DB >> 9769834

Breath-hold coronary MR angiography with volume-targeted imaging.

P A Wielopolski1, R J van Geuns, P J de Feyter, M Oudkerk.   

Abstract

PURPOSE: To illustrate a new concept for fast coronary artery screening with breath-hold volume targeted magnetic resonance (MR) imaging.
MATERIALS AND METHODS: Ten volunteers and 25 patients were imaged at a field strength of 1.5 T with an MR system with phased-array-coil reception and capable of echo-planar imaging. End-expiration breath-hold volume localization of the entire heart was performed with three-dimensional (3D) multishot segmented echo-planar imaging in 16-22 heartbeats. Interaction with a multiplaner reformation platform provided the optimal double-oblique volumes necessary to target seven coronary artery segments. Each segment was evaluated with 24-mm-thick volumes and breath holds at end expiration and magnetization transfer-enhanced 3D turbo fast low-angle shot imaging in 21 heartbeats. An intravascular contrast agent was used in eight patients to improve blood-myocardium contrast for the heart volume localizer acquisitions.
RESULTS: The entire coronary tree was consistently covered in fewer than 13 breath holds. The scheme was successful in all volunteers and in 22 patients who could achieve adequate breath hold. With end-expiration acquisitions, the prescribed 24-mm-thick volumes were reproducible for all coronary segments in all cooperative subjects.
CONCLUSION: Despite its status as the indisputable standard of reference for the detection of coronary artery disease, conventional coronary angiography remains costly and highly invasive, with associated risks of major complications, including stroke and death. Breath-hold volume targeted acquisitions permit rapid localization and coverage of the entire coronary tree with adequate resolution for evaluating the coronary arteries.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9769834     DOI: 10.1148/radiology.209.1.9769834

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  16 in total

1.  Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique.

Authors:  R J van Geuns; H G de Bruin; B J Rensing; P A Wielopolski; M D Hulshoff; P M van Ooijen; M Oudkerk; P J de Feyter
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  Imaging of an aberrant right coronary artery with retrospective respiratory-gated 3D-MR angiography.

Authors:  O M Kalinkin; P K Woodard; P A Ludbrook; F R Gutierrez
Journal:  Int J Cardiovasc Imaging       Date:  2001-02       Impact factor: 2.357

3.  Volume coronary angiography using targeted scans (VCATS): a new strategy in MR coronary angiography.

Authors:  R J van Geuns; P A Wielopolski; A J Wardeh; H G de Bruin; M Oudkerk; P J de Feyter
Journal:  Int J Cardiovasc Imaging       Date:  2001-10       Impact factor: 2.357

4.  Magnetic resonance imaging for the non-invasive detection of stenosis in coronary artery bypass grafts: clinical reality?

Authors:  E E van der Wall; S E Langerak
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

Review 5.  Coronary MR angiography.

Authors:  A J Duerinckx
Journal:  Int J Cardiovasc Imaging       Date:  2001-12       Impact factor: 2.357

6.  Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment.

Authors:  Martijn S Dirksen; Hildo J Lamb; Rob van der Geest; Albert de Roos
Journal:  Eur Radiol       Date:  2003-08-02       Impact factor: 5.315

7.  MRI in the detection of stenosis in coronary artery bypass grafts: are invasive techniques still needed?

Authors:  S E Langerak; E E van der Wall
Journal:  Neth Heart J       Date:  2003-01       Impact factor: 2.380

Review 8.  Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.

Authors:  Elmar Spuentrup; Rene M Botnar
Journal:  Eur Radiol       Date:  2005-08-25       Impact factor: 5.315

9.  Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease.

Authors:  Richard M McCarthy; Vibhas S Deshpande; Nirat Beohar; Sheridan N Meyers; Steven M Shea; Jordin D Green; Xin Liu; Xiaoming Bi; F Scott Pereles; John Paul Finn; Charles J Davidson; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

10.  Whole-heart contrast-enhanced coronary magnetic resonance angiography using gradient echo interleaved EPI.

Authors:  Himanshu Bhat; Sven Zuehlsdorff; Xiaoming Bi; Debiao Li
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.